Specifications
| Fuel | diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 91 kW |
| Standby kVA | 15 |
| Prime power | 13 kW |
| Alternator | LLB1014L |
| Voltage options | 220 V, 240 V |
| Phase | Single Phase |
| Power factor | 1 |
| Dimensions (L×W×H) | 1320×552×1258 mm |
| Dry weight | 715 kg |
| Sound level | 88.0 dBA @ 15 m |
| Fuel tank | 45.0 L |
Common questions
What is the power rating of the FG Wilson P13P2S?
The FG Wilson P13P2S is rated 91 kW standby (15.5 kVA).
What engine does the FG Wilson P13P2S use?
The FG Wilson P13P2S is powered by the 404C-22G1 engine.
What fuel does the FG Wilson P13P2S use?
The FG Wilson P13P2S runs on diesel.
What alternator does the FG Wilson P13P2S use?
The FG Wilson P13P2S uses a LLB1014L alternator.
Parts
1| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 955-806 | Black zinc die cast hinges tested and proven to withstand extremely corrosive conditions | Service part / kit | PartsGeek |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 4.5 | 1.2 |
| Standby | 39.0 | ||
| Standby | 100% | 4.8 | 1.3 |
Available documents
Brochure — 10-22 kVA Range Enclosure (FG Wilson)Brochure — 10-35 kVA Hi Ambient Range (FG Wilson)Spec sheet — 10-22 kva sa mobile enclosure(gb) (FG Wilson)Spec sheet — 10-35 KVA CAHA Enc (it) (FG Wilson)Spec sheet — 10-35 kVA CAHA Mobile (FG Wilson)Spec sheet — 10-35 kva sa mobile enclosure(gb) (FG Wilson)Spec sheet — F 10-35 kVA CAHA Enc F (FG Wilson)Spec sheet — FR 10-22 kva cae mobile (FG Wilson)Spec sheet — FR Product Rating Summary (FG Wilson)Spec sheet — GE 10-35 KVA CAHA Enc (FG Wilson)Spec sheet — ITA 10-22 KVA CAE (FG Wilson)Spec sheet — P13P2S-P14E2S(1pp).qxd (FG Wilson)Spec sheet — P13P2S-P14E2S(F) (FG Wilson)Spec sheet — P13P2S-P14E2S(G) (FG Wilson)Spec sheet — P13P2S-P14E2S(I) (FG Wilson)Spec sheet — P13PS2-P14E2S(P) (FG Wilson)Spec sheet — Product Rating Summary (FG Wilson)Spec sheet — RU 10-35 KVA CAHA Enc (FG Wilson)Spec sheet — SP 10-35kva caha mobile (FG Wilson)Spec sheet — p13p2s-p14e2s(1pp)gb (FG Wilson)Reference — 10-22 KVA CAE Mobile SU (FG Wilson)Reference — 10-22 kVA CAE Enclosure (FG Wilson)Reference — 10-35 kVA CAHA Enclosure (FG Wilson)Reference — 10-35 kVA Enclosure(GB)(0507) (FG Wilson)Reference — 10-35 kva enclosure(gb) (FG Wilson)Reference — GE 10-35 KVA CAHA Mobile (FG Wilson)Reference — RU 10-22 KVA CAE Enclosure (FG Wilson)Reference — RU 10-35 KVA CAHA Mobile (FG Wilson)Reference — SP 10-22 kva cae mobile (FG Wilson)