Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 440 kW |
| Standby kVA | 605 |
| Prime power | 440 kW |
| Controller | 1PXFS8J[BSE |
| Oil capacity | 55.5 L |
| Alternator | Leroy-Somer LL7024F |
| Voltage options | 415/240 V, 400/230 V, 380/220 V |
| Phase | 3 |
| Power factor | 0.8 |
| Circuit breaker | 3 Pole .$$# A |
| Battery voltage | 24 V |
| Battery quantity | 1 |
| Coolant capacity | 68.5 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 3900×1461×2156 mm |
| Dry weight | 4264 kg |
| Fuel tank | 1132.0 L |
Engine
| Oil capacity | 9.0 L |
|---|---|
| Coolant capacity | 10.0 L |
| Displacement | 18.1 L |
| Aspiration | Turbocharged Air To Air Charge Cooled |
| Rated speed | 2400 rpm |
Filters for the Perkins 2806A-E18TAG1
2Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P551808 | Lube Filter, Spin-On Full Flow | PERKINS 4587260, NAPA 7792, BALDWIN B7299, CLAAS 0000900651 | KuduParts $80.00 |
| Fuel filter | P551311 | Fuel Filter, Spin-On Secondary | PERKINS 4650996, BALDWIN BF7587, TAMROCK 019854051, LOESING 025133 | KuduParts $147.00 FridayParts $151.84 |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | MJB 160 MB4 | — | 100 hr | ||
| Fuel filter | — | 100 hr | |||
| Oil filter | MJB 160 MB4 | — | 100 hr | ||
| Belt | MJB 160 MB4 | — | 100 hr | ||
| Oil | MJB 160 MB4 | 0.71 l | — | 100 hr | |
| Spark plug | MJB 160 MB4 | — | 100 hr |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Common questions
What size generator is the FG Wilson P605-1?
The FG Wilson P605-1 is rated 440 kW standby (605.0 kVA).
What engine does the FG Wilson P605-1 use?
The FG Wilson P605-1 is powered by the Perkins 2806A-E18TAG1 engine.
What kind of fuel does the FG Wilson P605-1 run on?
The FG Wilson P605-1 runs on Diesel.
What's the oil capacity on a FG Wilson P605-1?
The Perkins 2806A-E18TAG1 engine in the FG Wilson P605-1 has an oil capacity of 9.0 liters.
How much coolant does the FG Wilson P605-1 hold?
The FG Wilson P605-1 cooling system holds 68.5 liters (18.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the dry weight of the FG Wilson P605-1?
The FG Wilson P605-1 has a dry weight of 4264 kg (9400 lb).
How big is the fuel tank on the FG Wilson P605-1?
The FG Wilson P605-1 has a 1132 liter (299 US gallon) fuel tank.
What voltage does the FG Wilson P605-1 produce?
The FG Wilson P605-1 is offered in 415/240 V, 400/230 V, 380/220 V, 3-phase.
How many cold cranking amps does the FG Wilson P605-1 require?
The FG Wilson P605-1 uses 1 battery, 24 V each, per the manufacturer specification sheet.
What alternator does the FG Wilson P605-1 use?
The FG Wilson P605-1 uses a Leroy-Somer LL7024F alternator.
Parts
1| Part # | Description | Qty | System | |
|---|---|---|---|---|
| P26-1S | Two large doors on each side | 2 | Service part / kit | Amazon eBay $117.00 |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 50% | 57.8 | 15.3 |
| Prime | 75% | 81.5 | 21.5 |
| Prime | 100% | 108.0 | 28.5 |
| Standby | 62.3 | 16.5 | |
| Standby | 75% | 89.2 | 23.6 |
| Standby | 100% | 119.3 | 31.5 |
Available documents
This page was generated from the 11 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.