Home›FG Wilson›FG Wilson 1103

FG Wilson 1103 Generator Set

The FG Wilson 1103 is a 24 kW (30 kVA) Diesel standby generator set powered by a FG Wilson 1103A engine. It is available at 400 V and 480 V, 3-phase, 50 Hz and rated 15 A. It holds about 2.96 L (0.8 gal) of oil and 2.96 L (0.8 gal) of coolant, with a maximum ambient rating of 45 °C. Starting uses 1 group-12 battery rated 500 CCA at 12 V. The set measures 1570×760×1229 mm (61.8×29.9×48.4 in), weighs about 699 kg (1541 lb) and produces 70 dBA at 7 m. An integrated tank holds 71 L (18.8 gal), roughly 18 hours of runtime.

24 kW
Standby
11.0 L
Displacement
2.96 L
Oil capacity
1
Document types

How to read your FG Wilson serial & model number →

Typical fuel consumption for 20–25 kW Diesel generators →

Compare with other 20–25 kW Diesel generators →

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power24 kW
Standby kVA30
EmissionsC
ControllerStandard
Oil capacity2.96 L
AlternatorLeroy-Somer LL3014E
Voltage options400 V, 480 V
PhaseThree-phase
Rated current15 A
Power factor0.8
Circuit breaker20 A
Battery group12V
Battery cranking500 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity2.96 L
Max ambient45 °C
Dimensions (L×W×H)1570×760×1229 mm
Dry weight699 kg
Sound level70.0 dBA @ 7 m
Fuel tank71.0 L
Tank runtime18 hr

Engine

FG Wilson 1103A
Oil capacity2.96 L
Coolant capacity2.96 L
Displacement11.0 L
AspirationNatural
Rated speed1500 rpm

Common questions

What is the power rating of the FG Wilson 1103?

The FG Wilson 1103 is rated 24 kW standby (30.0 kVA).

Which engine powers the FG Wilson 1103?

The FG Wilson 1103 is powered by the FG Wilson 1103A engine.

What kind of fuel does the FG Wilson 1103 run on?

The FG Wilson 1103 runs on Diesel.

What is the oil capacity of the FG Wilson 1103?

The FG Wilson 1103A engine in the FG Wilson 1103 has an oil capacity of 2.96 liters.

What is the coolant capacity of the FG Wilson 1103?

The FG Wilson 1103 cooling system holds 2.96 liters (0.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the sound level of the FG Wilson 1103?

The FG Wilson 1103 is rated at 70.0 dBA at 7 m, per the manufacturer specification sheet.

How much does the FG Wilson 1103 weigh?

The FG Wilson 1103 has a dry weight of 699 kg (1541 lb).

How big is the fuel tank on the FG Wilson 1103?

The FG Wilson 1103 has a 71 liter (19 US gallon) fuel tank, giving about 18 hours of runtime.

What voltages is the FG Wilson 1103 available in?

The FG Wilson 1103 is offered in 400 V, 480 V, Three-phase-phase.

What battery does the FG Wilson 1103 use?

The FG Wilson 1103 uses 1 battery, 12 V each, 500 CCA, group 12V, per the manufacturer specification sheet.

Which alternator is fitted to the FG Wilson 1103?

The FG Wilson 1103 uses a Leroy-Somer LL3014E alternator.

Available documents

Spec sheet — Product Rating Sum(GB)(1113) (FG Wilson)Spec sheet — Product Rating(ES)0414) (FG Wilson)Spec sheet — Product Rating(GB)(1012b) (FG Wilson)Spec sheet — Product Rating(IT)(0713) (FG Wilson)

This page was generated from the 4 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Other sets with this engine