HomeFG WilsonFG Wilson P88E1

FG Wilson P88E1 Generator Set

The FG Wilson P88E1 is a 72 kW (88 kVA) standby generator set powered by a Perkins 1104A-44TG2 engine. It is available at 380 V and 480 V, 1-phase and 50 Hz. It holds about 8 L (2.1 gal) of oil and 13 L (3.4 gal) of coolant. The set measures 2149×752×1366 mm (84.6×29.6×53.8 in), weighs about 1010 kg (2227 lb) and produces 82.1 dBA at 1 m. An integrated tank holds 175 L (46.2 gal). The same 1104A-44TG2 engine also powers generator sets from AKSA, Caps, Generac, Lees, Multiphase Power, Noor Generator Technology, Olympian, Perkins and Younes.

72 kW
Standby
4.4 L
Displacement
8.0 L
Oil capacity
1
Document types

How to read your FG Wilson serial & model number →

Specifications

Frequency50.0 Hz
Standby power72 kW
Standby kVA88
Prime power70 kW
Oil capacity8.0 L
AlternatorLL2014L
Voltage options380 V, 415 V, 50 V, 480 V, 60 V
Phase3
Power factor0.8
Dimensions (L×W×H)2149×752×1366 mm
Dry weight1010 kg
Sound level63.6 dBA @ 1 m
Fuel tank175.0 L

Engine

Perkins 1104A-44TG2
Oil capacity8.0 L
Coolant capacity13.0 L
Displacement4.4 L
AspirationTurbocharged
Rated speed1500 rpm

Maintenance & consumables

for the Perkins 1104A-44TG2
ItemSpecCapacityPart #Interval
Air filter1200 hr find
Fuel filter1200 hr find
Oil filter9011031200 hr PartsGeek kuduparts $25.00
Belt1200 hr find
Coolant13.01200 hr
Coolant filter find
Oil

Compatible filters for the Perkins 1104A-44TG2 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.

  • Air filter: Donaldson P778972 Donaldson P780012

Common questions

What is the power rating of the FG Wilson P88E1?

The FG Wilson P88E1 is rated 72 kW standby (88.0 kVA).

What engine does the FG Wilson P88E1 use?

The FG Wilson P88E1 is powered by the Perkins 1104A-44TG2 engine.

What is the oil capacity of the FG Wilson P88E1?

The Perkins 1104A-44TG2 engine in the FG Wilson P88E1 has an oil capacity of 8.0 liters.

What alternator does the FG Wilson P88E1 use?

The FG Wilson P88E1 uses a LL2014L alternator.

Fuel consumption

RatingLoadL/hgal/h
Prime
Standby

Available documents

Spec sheet — 27-110 kva sa&ssa mobile enclosure(gb) (FG Wilson)Spec sheet — 27-165 kVA Enclosure(GB)(0507) (FG Wilson)Spec sheet — 27-165 kVA Enclosure(GB) (FG Wilson)Spec sheet — 27-200 kVA Enclosure(GB)(0608) (FG Wilson)Spec sheet — 27-200 kVA Enclosure(GB)(0609) (FG Wilson)Spec sheet — 27-200 kVA Enclosure(IT)(0608) (FG Wilson)Spec sheet — FR Product Rating Summary (FG Wilson)Spec sheet — GE Product Rating Summary (FG Wilson)Spec sheet — P80P1-P88E1(1PP)IT (FG Wilson)Spec sheet — P80P1-P88E1(1pp) (FG Wilson)Spec sheet — Product Rating Summary(S) (FG Wilson)Spec sheet — Product Rating Summary (FG Wilson)Spec sheet — RU Product Rating Summary (FG Wilson)Spec sheet — p80p1-p88e1(1pp)gb (FG Wilson)