HomeFG WilsonFG Wilson UG14P1

FG Wilson UG14P1 Generator Set

The FG Wilson UG14P1 is a 11.2 kW (14 kVA) LPG, Nat Gas standby generator set powered by a FG Wilson HM 1.8L engine. It is available at 380 V and 480 V, 50 Hz. It holds about 4.5 L (1.2 gal) of oil and 14.1 L (3.7 gal) of coolant. The set measures 1970×850×1175 mm (77.6×33.5×46.3 in), weighs about 560 kg (1235 lb) and produces 52.8 dBA at 15 m.

11 kW
Standby
1.8 L
Displacement
4.5 L
Oil capacity
3
Document types

How to read your FG Wilson serial & model number →

Typical fuel consumption for 10–15 kW Bi-Fuel (NG/LP) generators →

Compare with other 10–15 kW Bi-Fuel (NG/LP) generators →

Specifications

FuelLPG, Nat Gas
Frequency50.0 Hz
Standby power11 kW
Standby kVA14
Prime power10 kW
ControllerPowerWizard 1
Oil capacity4.5 L
AlternatorLUA1014NX
Voltage options380/220 V, 400/230 V, 415/240 V, 220/127 V, 240/120 V, 208/120 V, 440/254 V, 480/277 V, 240/139 V
Coolant capacity['14.1 (804)', '17.1 (970)'] L
Dimensions (L×W×H)1970×850×1175 mm
Dry weight405 kg
Sound level52.8 dBA @ 15 m

Engine

FG Wilson HM 1.8L
Coolant capacity14.1 L
Displacement1.8 L
AspirationNaturally Aspirated
Rated speed3000 rpm

Maintenance & consumables

for the FG Wilson HM 1.8L
ItemSpecCapacityPart #Interval
Fuel filterReplaceable Element
Oil filterSpin-On, Full Flow
OilAP1CF4 15W-40

Common questions

What size generator is the FG Wilson UG14P1?

The FG Wilson UG14P1 is rated 11 kW standby (14.0 kVA).

What engine does the FG Wilson UG14P1 use?

The FG Wilson UG14P1 is powered by the FG Wilson HM 1.8L engine.

What fuel does the FG Wilson UG14P1 use?

The FG Wilson UG14P1 runs on LPG, Nat Gas.

What alternator does the FG Wilson UG14P1 use?

The FG Wilson UG14P1 uses a LUA1014NX alternator.

Parts

1
Part #DescriptionQtySystem
P26-1STwo large doors on each side2Service part / kit Amazon eBay $117.00

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime2.20.58
Standby2.20.58

Available documents

Spec sheet — Gas Powered Range(IT) (FG Wilson)Spec sheet — Gas Powered Range (FG Wilson)Spec sheet — UG14P1+UG16.5E1(4PP)(IT)(0111) (FG Wilson)Spec sheet — UG14P1+UG16E1(4PP)(SP)(0111) (FG Wilson)Spec sheet — UG14P1-UG16.5E1(1PP)(GB) (FG Wilson)Spec sheet — UG14P1-UG16.5E1(1PP)(IT) (FG Wilson)Spec sheet — UG14P1-UG16.5E1(1PP)GB(0207) (FG Wilson)Spec sheet — UG14P1 1p (FG Wilson)Reference — GE Gas Powered Range (FG Wilson)Reference — Gas Powered Range Enclosure(GB)(1110) (FG Wilson)Reference — Gas+Powered+Range+Enclosure(ES)(1110) (FG Wilson)Reference — Gas+Powered+Range+Enclosure(IT)(1110) (FG Wilson)Reference — ITA Gas Powered Range (FG Wilson)Reference — gas powered range sa enclosure(gb) (FG Wilson)Parts manual — SP Gas Powered Range (FG Wilson)