The PowerWizard 1 is a generator-set controller. It is used on generator sets from FG Wilson, including the S320P1, S350E1, UG11P1S and UG13E1S.
| Display | LCD Display with adjustable contrast and backlight with auto power off |
|---|---|
| Communications | CAN 1 data link – J1939 |
| Supply voltage | 10.5-32V DC |
| Protections | Fail to Start, Low Oil Pressure, High Engine Temperature, Low/High Battery Voltage, Battery Charger Failure (if fitted), Underspeed, Overspeed, Loss of Engine Speed Detection, 2 spare fault channels* |
| Analog inputs | Comptage de courant alternatif, Volts 3 phases (L-L et L-N), Ampères (par phase & moyenne), Fréquence, Comptage de courant continu, Volts batterie, Heures de marche moteur, Température de chemise d’eau (en °C ou °F), Pression d’huile (en psi, kPa ou bar), Vitesse du moteur (tr/mn) |
| Code | Meaning | Cause |
|---|---|---|
| 2 spare fault channels* | 2 spare fault channels* | * One spare fault channel available on models P730P1 - P1100E1 (high exhaust temperature alarm fitted as standard) |
| P1250 - P2200E | Allarme alta temperatura gas di scarico e valvola d’intercettazione dell’aria (serie) | |
| P730P1 - P1100E1 | Allarme alta temperatura gas di scarico (serie) |
| Symptom | Cause |
|---|---|
| Fail to Start | |
| Low Oil Pressure | |
| High Engine Temperature | |
| Low/High Battery Voltage | |
| Battery Charger Failure (if fitted) | |
| Underspeed, Overspeed | |
| Loss of Engine Speed Detection | |
| No spare fault channels available on models P1250 - P2200E | High exhaust temperature alarm & air shut-off valve fitted as standard |
| Défaut démarrage | |
| Basse pression d’huile | |
| Haute température moteur | |
| Haute/basse tension batterie | |
| Défaut chargeur de batterie (si monté) | |
| Sous-vitesse, survitesse | |
| Perte de détection de vitesse moteur | |
| One spare fault channel available on models P730P1 - P1100E1 (high exhaust temperature alarm fitted as standard) | |
| No spare fault channels available on models P1250 - P2200E (high exhaust temperature alarm & air shut-off valve fitted as standard) | |
| Avviamento fallito | |
| Pressione olio bassa | |
| Temperatura elevata del motore | |
| Tensione batteria bassa/alta | |
| Guasto del caricabatteria (se installato) | |
| Sottovelocità, sovravelocità | |
| Rilevamento perdita di velocità del motore |
Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Extracted directly from this controller's manual.
Also fitted to: FG Wilson P1000P1/P1100E1, FG Wilson P1500P3/P1650E3, FG Wilson PowerWizard 1.0, FG Wilson UG11P1S/UG13E1S, FG Wilson XP100/ XP110E, FG Wilson XP135/ XP150E, FG Wilson XP150P1/ XP165E1, FG Wilson XP24P1S/XP26E1S, FG Wilson XP27P1/ XP30E1, FG Wilson XP30P1/ XP33E1, FG Wilson XP32P3S/XP35E3S, FG Wilson XP40P1S/XP44E1S, FG Wilson XP40P3/ XP44E3, FG Wilson XP45P3/ XP50E3, FG Wilson XP45P3S/XP50E3S, FG Wilson XP50P1/ XP55E1, FG Wilson XP58P1S/XP64E1S, FG Wilson XP60P3/ XP65E3, FG Wilson XP80P1/ XP88E1, FG Wilson XP80P1/XP88P1, FG Wilson XP90/ XP100E, FG Wilson easYgen-3200.