Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 1320 kW |
| Standby kVA | 1650 |
| Prime power | 1200 kW |
| Controller | DSE7410 |
| Oil capacity | 45.8 L |
| Alternator | Leroy-Somer LL8224N |
| Voltage options | 400/230 V, 415/240 V, 380/220 V |
| Phase | 3 |
| Rated current | 1331 A |
| Power factor | 0.8 |
| Circuit breaker | 1331 A |
| Battery group | 40 |
| Battery voltage | 24 V |
| Battery quantity | 1 |
| Coolant capacity | 218.0 L |
| Max ambient | 25 °C |
| Dimensions (L×W×H) | 5044×2200×2461 mm |
| Dry weight | 10181 kg |
| Fuel tank | 177.0 L |
| Tank runtime | 159.8 hr |
Engine
| Oil capacity | 177.6 L |
|---|---|
| Coolant capacity | 240.0 L |
| Displacement | 45.842 L |
| Aspiration | Turbocharged and air to air charge cooled |
| Rated speed | 1500 rpm |
Same engine, other brands
2 brandsThe Perkins 4012-46TAG2A in this set also powers 2 generator sets sold under 2 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.
| Brand | Models |
|---|---|
| AKSA | AD1250 |
| Pramac | P1500P3 - P1650E3 |
Maintenance & consumables
for the Perkins 4012-46TAG2A| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | — | ||||
| Fuel filter | — | ||||
| Oil filter | — | 10 hr | |||
| Battery | — | ||||
| Belt | — | ||||
| Coolant | — | ||||
| Oil | — | ||||
| Spark plug | — |
Common questions
What size generator is the FG Wilson P1650-1?
The FG Wilson P1650-1 is rated 1320 kW standby (1650.0 kVA).
What engine does the FG Wilson P1650-1 use?
The FG Wilson P1650-1 is powered by the Perkins 4012-46TAG2A engine.
Is the FG Wilson P1650-1 diesel or gas?
The FG Wilson P1650-1 runs on Diesel.
How much oil does the FG Wilson P1650-1 take?
The Perkins 4012-46TAG2A engine in the FG Wilson P1650-1 has an oil capacity of 177.6 liters.
What is the cooling system capacity of the FG Wilson P1650-1?
The FG Wilson P1650-1 cooling system holds 218 liters (57.6 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the prime power rating of the FG Wilson P1650-1?
The FG Wilson P1650-1 is rated 1200 kW prime (1500 kVA), against 1320 kW standby.
How much does the FG Wilson P1650-1 weigh?
The FG Wilson P1650-1 has a dry weight of 10181 kg (22445 lb).
What size fuel tank does the FG Wilson P1650-1 have?
The FG Wilson P1650-1 has a 177 liter (47 US gallon) fuel tank, giving about 159.8 hours of runtime.
What voltages is the FG Wilson P1650-1 available in?
The FG Wilson P1650-1 is offered in 400/230 V, 415/240 V, 380/220 V, 3-phase.
What size battery does the FG Wilson P1650-1 need?
The FG Wilson P1650-1 uses 1 battery, 24 V each, group 40, per the manufacturer specification sheet.
What alternator does the FG Wilson P1650-1 use?
The FG Wilson P1650-1 uses a Leroy-Somer LL8224N alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 296.6 | 78.4 |
| Standby | 100% | 326.3 | 86.2 |
Available documents
This page was generated from the 1 manufacturer document above by automated extraction; every figure shown is copied from one of them. How the data is compiled.