Home›FG Wilson›FG Wilson 2506

FG Wilson 2506 Generator Set

The FG Wilson 2506 is a 400 kW (455 kVA) Diesel standby generator set powered by a FG Wilson 2506A engine. It is available at 400 V and 480 V, 3-phase, 50 Hz and rated 15 A. It holds about 2.96 L (0.8 gal) of oil and 2.96 L (0.8 gal) of coolant, with a maximum ambient rating of 45 °C. Starting uses 1 group-12 battery rated 500 CCA at 12 V. The set measures 3800×1131×2215 mm (149.6×44.5×87.2 in), weighs about 3676 kg (8104 lb) and produces 70 dBA at 7 m. An integrated tank holds 888 L (234.6 gal), roughly 34 hours of runtime.

400 kW
Standby
11.0 L
Displacement
2.96 L
Oil capacity
1
Document types

How to read your FG Wilson serial & model number →

Typical fuel consumption for 400–405 kW Diesel generators →

Compare with other 400–405 kW Diesel generators →

Specifications

FuelDiesel
Frequency50.0 Hz
Standby power400 kW
Standby kVA455
Prime power400 kW
EmissionsC
ControllerStandard
Oil capacity2.96 L
AlternatorLeroy-Somer LL3014E
Voltage options400 V, 480 V
PhaseThree-phase
Rated current15 A
Power factor0.8
Circuit breaker20 A
Battery group12V
Battery cranking500 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity2.96 L
Max ambient45 °C
Dimensions (L×W×H)3800×1131×2215 mm
Dry weight3676 kg
Sound level70.0 dBA @ 7 m
Fuel tank888.0 L
Tank runtime34 hr

Engine

FG Wilson 2506A
Oil capacity2.96 L
Coolant capacity2.96 L
Displacement11.0 L
AspirationNatural
Rated speed1500 rpm

Common questions

What size generator is the FG Wilson 2506?

The FG Wilson 2506 is rated 400 kW standby (455.0 kVA).

Which engine powers the FG Wilson 2506?

The FG Wilson 2506 is powered by the FG Wilson 2506A engine.

What fuel does the FG Wilson 2506 use?

The FG Wilson 2506 runs on Diesel.

What's the oil capacity on a FG Wilson 2506?

The FG Wilson 2506A engine in the FG Wilson 2506 has an oil capacity of 2.96 liters.

What is the coolant capacity of the FG Wilson 2506?

The FG Wilson 2506 cooling system holds 2.96 liters (0.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

How loud is the FG Wilson 2506?

The FG Wilson 2506 is rated at 70.0 dBA at 7 m, per the manufacturer specification sheet.

What is the dry weight of the FG Wilson 2506?

The FG Wilson 2506 has a dry weight of 3676 kg (8104 lb).

What size fuel tank does the FG Wilson 2506 have?

The FG Wilson 2506 has a 888 liter (235 US gallon) fuel tank, giving about 34 hours of runtime.

What voltage does the FG Wilson 2506 produce?

The FG Wilson 2506 is offered in 400 V, 480 V, Three-phase-phase.

What battery does the FG Wilson 2506 use?

The FG Wilson 2506 uses 1 battery, 12 V each, 500 CCA, group 12V, per the manufacturer specification sheet.

What alternator does the FG Wilson 2506 use?

The FG Wilson 2506 uses a Leroy-Somer LL3014E alternator.

Available documents

Spec sheet — Product Rating Sum(GB)(1113) (FG Wilson)Spec sheet — Product Rating(ES)0414) (FG Wilson)Spec sheet — Product Rating(GB)(1012b) (FG Wilson)Spec sheet — Product Rating(IT)(0713) (FG Wilson)

This page was generated from the 4 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.