Specifications
| Frequency | 50.0 Hz |
|---|---|
| Standby power | 26 kW |
| Standby kVA | 26 |
| Prime power | 24 kW |
| Emissions | EU IIIa |
| Controller | DCP-10, PowerWizard 1.1 |
| Oil capacity | 7.9 L |
| Alternator | LLB1514J |
| Voltage options | 230 V |
| Phase | Single Phase |
| Power factor | 1 |
| Circuit breaker | [1500, 760] A |
| Coolant capacity | 10.2 L |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 1570×760×1229 mm |
| Dry weight | 686 kg |
| Sound level | 60.5 dBA @ 15 m |
| Fuel tank | 71.0 L |
Engine
| Oil capacity | 10.2 L |
|---|---|
| Coolant capacity | 23.9 L |
| Displacement | 3.3 L |
| Aspiration | Naturally Aspirated |
| Rated speed | 1925 rpm |
Maintenance & consumables
for the Perkins 1103D-33G3| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Replaceable Element | 1000051238 | 5000 hr | PartsGeek | |
| Fuel filter | — | 500 hr | find | ||
| Oil filter | — | 5000 hr | find | ||
| Belt | — | find | |||
| Coolant | 23.9 litres | — | 1000 hr | ||
| Oil | Lubricating oil capacity: Total system ...8.3 litres (17.5 pt) | 23.9 litres | — | 500 hr |
Common questions
What is the power rating of the FG Wilson P26-6S?
The FG Wilson P26-6S is rated 26 kW standby (26.0 kVA).
What engine does the FG Wilson P26-6S use?
The FG Wilson P26-6S is powered by the Perkins 1103D-33G3 engine.
What is the oil capacity of the FG Wilson P26-6S?
The Perkins 1103D-33G3 engine in the FG Wilson P26-6S has an oil capacity of 10.2 liters.
What alternator does the FG Wilson P26-6S use?
The FG Wilson P26-6S uses a LLB1514J alternator.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 50% | 4.0 | |
| Prime | 75% | 5.7 | |
| Prime | 100% | 7.4 | |
| Prime | 110% | 7.9 | |
| Standby | 50% | 4.3 | |
| Standby | 75% | 6.1 | |
| Standby | 100% | 7.9 |