HomeFG WilsonFG Wilson P15P2S

FG Wilson P15P2S Generator Set

The FG Wilson P15P2S is a 91 kW (15 kVA) diesel standby generator set powered by a Perkins 404C-22G2 engine. It is available at 220 V, single-phase and 60 Hz. The set measures 1684×860×1252 mm (66.3×33.9×49.3 in), weighs about 728 kg (1605 lb) and produces 89 dBA at 1 m. An integrated tank holds 45 L (11.9 gal), roughly 682 hours of runtime.

91 kW
Standby
2.2 L
Displacement
2
Document types

How to read your FG Wilson serial & model number →

Typical fuel consumption for 90–95 kW Diesel generators →

Compare with other 90–95 kW Diesel generators →

Specifications

Fueldiesel
Frequency60.0 Hz
Standby power91 kW
Standby kVA15
Prime power15 kW
AlternatorLeroy-Somer LLB1014N
Voltage options220 V, 240 V
PhaseSingle Phase
Power factor1.0
Max ambient50 °C
Dimensions (L×W×H)1684×860×1252 mm
Dry weight469 kg
Sound level89.0 dBA @ 1 m
Fuel tank45.0 L
Tank runtime682 hr

Engine

Perkins 404C-22G2
Displacement2.2 L
AspirationNaturally Aspirated
Rated speed1800 rpm

Common questions

What size generator is the FG Wilson P15P2S?

The FG Wilson P15P2S is rated 91 kW standby (15.0 kVA).

What engine does the FG Wilson P15P2S use?

The FG Wilson P15P2S is powered by the Perkins 404C-22G2 engine.

What kind of fuel does the FG Wilson P15P2S run on?

The FG Wilson P15P2S runs on diesel.

What is the prime power rating of the FG Wilson P15P2S?

The FG Wilson P15P2S is rated 15 kW prime (15 kVA), against 91 kW standby.

What is the sound level of the FG Wilson P15P2S?

The FG Wilson P15P2S is rated at 89.0 dBA at 1 m, per the manufacturer specification sheet.

What is the dry weight of the FG Wilson P15P2S?

The FG Wilson P15P2S has a dry weight of 469 kg (1033 lb).

What size fuel tank does the FG Wilson P15P2S have?

The FG Wilson P15P2S has a 45 liter (12 US gallon) fuel tank, giving about 682 hours of runtime.

What voltage does the FG Wilson P15P2S produce?

The FG Wilson P15P2S is offered in 220 V, 240 V, Single Phase-phase.

What alternator does the FG Wilson P15P2S use?

The FG Wilson P15P2S uses a Leroy-Somer LLB1014N alternator.

Parts

1
Part #DescriptionQtySystem
955-806Black zinc die cast hinges tested and proven to withstand extremely corrosive conditionsService part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime100%5.11.3
Standby100%5.81.5

Available documents

Spec sheet — 10-22 kva sa mobile enclosure(gb) (FG Wilson)Spec sheet — 10-35 KVA CAHA Enc (it) (FG Wilson)Spec sheet — 10-35 kVA CAHA Mobile (FG Wilson)Spec sheet — F 10-35 kVA CAHA Enc F (FG Wilson)Spec sheet — FR 10-22 kva cae mobile (FG Wilson)Spec sheet — GE 10-35 KVA CAHA Enc (FG Wilson)Spec sheet — ITA 10-22 KVA CAE (FG Wilson)Spec sheet — P15P2S-P16-5E2S(P) (FG Wilson)Spec sheet — P15P2S-P16-5E2S(S) (FG Wilson)Spec sheet — P15P2S-P16.5E2S(1pp).qxd (FG Wilson)Spec sheet — P15P2S-P16.5E2S(F) (FG Wilson)Spec sheet — P15P2S-P16.5E2S(G) (FG Wilson)Spec sheet — P15P2S-P16 5E2S(I) (FG Wilson)Spec sheet — RU 10-35 KVA CAHA Enc (FG Wilson)Spec sheet — SP 10-35kva caha mobile (FG Wilson)Spec sheet — p15p2s-p16.5e2s(1pp)gb (FG Wilson)Reference — 10-22 KVA CAE Mobile SU (FG Wilson)Reference — 10-22 kVA CAE Enclosure (FG Wilson)Reference — 10-22 kVA Range Enclosure (FG Wilson)Reference — 10-35 kVA CAHA Enclosure (FG Wilson)Reference — 10-35 kVA Enclosure(GB)(0507) (FG Wilson)Reference — 10-35 kva enclosure(gb) (FG Wilson)Reference — 10-35 kVA Hi Ambient Range (FG Wilson)Reference — FR Product Rating Summary (FG Wilson)Reference — GE 10-35 KVA CAHA Mobile (FG Wilson)Reference — RU 10-22 KVA CAE Enclosure (FG Wilson)Reference — RU 10-35 KVA CAHA Mobile (FG Wilson)Reference — SP 10-22 kva cae mobile (FG Wilson)

This page was generated from the 28 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Other sets with this engine