Specifications
| Fuel | diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 16.5 kW |
| Standby kVA | 16 |
| Prime power | 76 kW |
| Alternator | Leroy-Somer LLB1014N |
| Voltage options | 220 V, 240 V |
| Phase | Single Phase |
| Power factor | 1.0 |
| Max ambient | 50 °C |
| Dimensions (L×W×H) | 1684×860×1252 mm |
| Dry weight | 469 kg |
| Sound level | 58.2 dBA @ 1 m |
| Fuel tank | 45.0 L |
| Tank runtime | 802 hr |
Filters for the Perkins 404C-22G2
2Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Fuel filter | P556245 | Fuel Filter, Cartridge | PERKINS 26511171, PERKINS 26556611, NAPA 3166, RENAULT VI 0001231108 | KuduParts $20.00 FridayParts $22.11 |
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P550939 | Lube Filter, Spin-On Full Flow | NAPA 1521, NAPA 21521, LPM 00013505084, YALE 0012097262 | FridayParts $23.20 |
Common questions
What is the power rating of the FG Wilson P16.5E2S?
The FG Wilson P16.5E2S is rated 16.5 kW standby (16.5 kVA).
What engine does the FG Wilson P16.5E2S use?
The FG Wilson P16.5E2S is powered by the Perkins 404C-22G2 engine.
Is the FG Wilson P16.5E2S diesel or gas?
The FG Wilson P16.5E2S runs on diesel.
What is the prime power rating of the FG Wilson P16.5E2S?
The FG Wilson P16.5E2S is rated 76 kW prime (20 kVA), against 16.5 kW standby.
What is the sound level of the FG Wilson P16.5E2S?
The FG Wilson P16.5E2S is rated at 58.2 dBA at 1 m, per the manufacturer specification sheet.
What is the dry weight of the FG Wilson P16.5E2S?
The FG Wilson P16.5E2S has a dry weight of 469 kg (1033 lb).
What size fuel tank does the FG Wilson P16.5E2S have?
The FG Wilson P16.5E2S has a 45 liter (12 US gallon) fuel tank, giving about 802 hours of runtime.
What voltages is the FG Wilson P16.5E2S available in?
The FG Wilson P16.5E2S is offered in 220 V, 240 V, Single Phase-phase.
What alternator does the FG Wilson P16.5E2S use?
The FG Wilson P16.5E2S uses a Leroy-Somer LLB1014N alternator.
Parts
2| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 950-819 | De acuerdo con nuestra política de continuo desarrollo del producto, nos reservamos el derecho a cambiar la especificación sin previo aviso. | Service part / kit | Amazon eBay | |
| 955-806 | Black zinc die cast hinges tested and proven to withstand extremely corrosive conditions | Service part / kit | Amazon eBay NAPA $22.40 |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 5.1 | 1.3 |
| Standby | 100% | 5.8 | 1.5 |
Source — consumption: P15P2S-P16-5E2S(P).
Available documents
This page was generated from the 24 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.