Specifications
| Fuel | Diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 240 kW |
| Standby kVA | 312 |
| Prime power | 200 kW |
| Emissions | C |
| Controller | Standard |
| Oil capacity | 2.96 L |
| Alternator | Leroy-Somer LL3014E |
| Voltage options | 400 V, 480 V |
| Phase | Three-phase |
| Rated current | 15 A |
| Power factor | 0.8 |
| Circuit breaker | 20 A |
| Battery group | 12V |
| Battery cranking | 500 CCA |
| Battery voltage | 12 V |
| Battery quantity | 1 |
| Coolant capacity | 2.96 L |
| Max ambient | 45 °C |
| Dimensions (L×W×H) | 3300×1100×1848 mm |
| Dry weight | 2452 kg |
| Sound level | 70.0 dBA @ 7 m |
| Fuel tank | 617.0 L |
| Tank runtime | 34 hr |
Engine
| Oil capacity | 2.96 L |
|---|---|
| Coolant capacity | 2.96 L |
| Displacement | 11.0 L |
| Aspiration | Natural |
| Rated speed | 1500 rpm |
Common questions
What is the power rating of the FG Wilson 1606?
The FG Wilson 1606 is rated 240 kW standby (312.5 kVA).
What engine does the FG Wilson 1606 use?
The FG Wilson 1606 is powered by the FG Wilson 1606A engine.
Is the FG Wilson 1606 diesel or gas?
The FG Wilson 1606 runs on Diesel.
How much oil does the FG Wilson 1606 take?
The FG Wilson 1606A engine in the FG Wilson 1606 has an oil capacity of 2.96 liters.
What is the coolant capacity of the FG Wilson 1606?
The FG Wilson 1606 cooling system holds 2.96 liters (0.8 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the FG Wilson 1606?
The FG Wilson 1606 is rated 200 kW prime (343 kVA), against 240 kW standby.
How loud is the FG Wilson 1606?
The FG Wilson 1606 is rated at 70.0 dBA at 7 m, per the manufacturer specification sheet.
How much does the FG Wilson 1606 weigh?
The FG Wilson 1606 has a dry weight of 2452 kg (5405 lb).
What size fuel tank does the FG Wilson 1606 have?
The FG Wilson 1606 has a 617 liter (163 US gallon) fuel tank, giving about 34 hours of runtime.
What voltages is the FG Wilson 1606 available in?
The FG Wilson 1606 is offered in 400 V, 480 V, Three-phase-phase.
How many cold cranking amps does the FG Wilson 1606 require?
The FG Wilson 1606 uses 1 battery, 12 V each, 500 CCA, group 12V, per the manufacturer specification sheet.
What alternator comes on the FG Wilson 1606?
The FG Wilson 1606 uses a Leroy-Somer LL3014E alternator.