Briggs & Stratton Repair Guides
41 step-by-step procedures compiled from Briggs & Stratton service manuals.
A. Yes- Move to Test 5: Check Starter Relay Signal (step 19).
10 kW, 8 kW
11. Check the condition of all wires, cables, and connectors in unit. Pay particular attention to gr
10 kW, 8 kW
A. Yes- Move to Test 3: Check Trickle Charge at Battery (step 15).
10 kW, 8 kW
Yes- Move to Test 6: Check Starter Solenoid Connection (step 23).
10 kW, 8 kW
Test 6: Check Starter Solenoid Connection
10 kW, 8 kW
B. No- Return to step 8 (under Test 1: Check Battery Voltage Supply).
10 kW, 8 kW
Test 7: Check Control Panel Output
10 kW, 8 kW
.6 VDC. Move to Test
10 kW, 8 kW
Test 8: Check Fuel Supply Pressure
10 kW, 8 kW
A. Yes- Move to Test 10: Check Fuel Pressure Regulator (step 17).
10 kW, 8 kW
Test 10: Check Fuel Pressure Regulator
10 kW, 8 kW
Test 11: Check Spark
10 kW, 8 kW
A. Yes- Ignition is functioning properly. Move to Test 12: Check Crankcase Vacuum (step 30).
10 kW, 8 kW
Test 12: Check Crankcase Vacuum
10 kW, 8 kW
Test 14: Measure Circuit Breaker Load-Side Voltage
10 kW, 8 kW
Test 16: Measure Circuit Breaker Line-Side
10 kW, 8 kW
Test 17: Check Alternator Rotor Winding Resistance
10 kW, 8 kW
Test Stator Power Windings
10 kW, 8 kW
Check AC Voltage
10 kW, 8 kW
A. Yes- Move to Test 5: Check Starter Relay Signal (step 19).: Test 2: Check Utility Voltage Input
10 kW, 8 kW
Test 2: Check Utility Voltage Input: Test 3: Check Trickle Charge at Battery
10 kW, 8 kW
Test 3: Check Trickle Charge at Battery: Test 4: Check Trickle Charge Fuse at Control Panel
10 kW, 8 kW
Test 4: Check Trickle Charge Fuse at Control Panel: continuity. Test fuse. Is continuity present?
10 kW, 8 kW
Test 5: Check Starter Relay Signal: Yes- Move to Test 6: Check Starter Solenoid Connection (step 23).
10 kW, 8 kW
Yes- Move to Test 6: Check Starter Solenoid Connection (step 23).: Test 6: Check Starter Solenoid Connection
10 kW, 8 kW
Test 6: Check Starter Solenoid Connection: B. No- Repair or replace main battery wiring between starter and starter relay. Retest.
10 kW, 8 kW
B. No- Repair or replace main battery wiring between starter and starter relay. Retest.
10 kW, 8 kW
.6 VDC. Move to Test: Test 8: Check Fuel Supply Pressure
10 kW, 8 kW
Test 8: Check Fuel Supply Pressure: Test 9: Check Fuel Solenoid and Thermal Fuses
10 kW, 8 kW
Test 9: Check Fuel Solenoid and Thermal Fuses: Test 10: Check Fuel Pressure Regulator
10 kW, 8 kW
Test 10: Check Fuel Pressure Regulator: Test 11: Check Spark
10 kW, 8 kW
Test 11: Check Spark: i) Yes- Move to Test 12: Check Crankcase Vacuum (step 30).
10 kW, 8 kW
B. No- See appropriate Engine Service Manual.
10 kW, 8 kW
B. No- Move to Test 14: Measure Circuit Breaker Load-Side Voltage (step 2).: Test 15: Measure Generator Voltage at Control
10 kW, 8 kW
Test 15: Measure Generator Voltage at Control: Test 16: Measure Circuit Breaker Line-Side
10 kW, 8 kW
Test 16: Measure Circuit Breaker Line-Side: Test 17: Check Alternator Rotor Winding Resistance
10 kW, 8 kW
Test 17: Check Alternator Rotor Winding Resistance: Test Stator Power Windings
10 kW, 8 kW
Test Stator Power Windings: Test Stator Excitation Windings (step 20).
10 kW, 8 kW
Test Stator Excitation Windings
10 kW, 8 kW
A. Yes- Move to Check Rotor Resistance Through Brush Wires (step 23).: Test 18: Perform AVR Bypass Tests
10 kW, 8 kW
Test 18: Perform AVR Bypass Tests
10 kW, 8 kW