Briggs & Stratton — Change Engine Oil
Maintenance · Lubrication
From a Briggs & Stratton service manual — check it applies to your exact model before use.
Browse Briggs & Stratton generators & specs →
Before you start
- Do not overfill.
Procedure
- Remove oil drain plug and drain oil while engine is still warm.
- Replace drain plug.
- Remove dipstick and refill slowly with new oil of proper service classification and viscosity grade.
- Refill to full mark on dipstick; dipstick must be screwed all the way in.
- Start and run engine to check for oil leaks.
Specs & values
- 1.65 liters (3-1/2 pints) with filter
- 1.42 liters (3 pints) without filter
Source: Briggs & Stratton service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.