Briggs & Stratton — To Replace Armature

Repair & overhaul · magneto

From a Briggs & Stratton service manual — check it applies to your exact model before use.

Browse Briggs & Stratton generators & specs →

Before you start

  • Do not use battery compound or tar as it will melt and run over the entire magneto assembly

Procedure

  1. Remove the armature lead wire from the contact spring and the high tension ignition cable from the secondary terminal loop in the armature
  2. Unscrew the two armature mounting screws and pry the armature loose with a screwdriver
  3. Place the dust cover clip under the upper mounting screw and tighten the lower mounting screw
  4. Solder the ignition cable to the terminal and fill the pocket formed with the flap with hydrolene
  5. Solder the armature lead wire to the contact spring, replace the dust cover and clip, and tighten the upper armature mounting screw
  6. Check that an air gap of .002 to .010 inch is maintained between the armature shoes and the flywheel poles

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Air gap .002 to .010 inch

Source: Briggs & Stratton service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.