Home›Repair guides›Briggs & Stratton›Idle Control Solenoid Adjustment

Briggs & Stratton — Idle Control Solenoid Adjustment

Adjustments

From a Briggs & Stratton service manual — check it applies to your exact model before use.

Browse Briggs & Stratton generators & specs →

Before you start

  • Let engine warm up before adjusting
  • Verify governor operation after adjustment

Procedure

  1. Set the idle control switch to OFF
  2. Unplug all electrical loads from the generator
  3. Connect an AC frequency meter to the generator's AC output receptacle
  4. Crank and start the engine, let stabilize and warm up
  5. Check frequency meter reading for proper governed speed
  6. Set idle control switch to ON
  7. Verify idle control solenoid energizes and engine decelerates to idle
  8. Check frequency meter reading at idle
  9. If outside range, loosen solenoid jam nut and turn solenoid to adjust
  10. Retighten jam nut after adjustment

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Target idle: 40-45 Hz (2100-2400 rpm)
  • Target high speed 60 Hz: 61.5-63.5 Hz (3690-3810 rpm)
  • Target high speed 50 Hz: 50.5-51.5 Hz (3030-3090 rpm)

Source: Briggs & Stratton service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.

More Briggs & Stratton repair guides →