Procedure

  1. Be sure fuel tank has ample supply of fresh, clean gasoline and fuel flows freely.
  2. Inspect and adjust idle needle valve; check that choke closes completely.
  3. If engine will not start, remove and inspect spark plugs.
  4. If plugs are wet, look for overchoking, rich mixture, water in fuel, float needle stuck open, or plugged air cleaner.
  5. If plug is dry, look for leaking mounting gaskets, dirty carburetor, float needle stuck shut, inoperative fuel pump, or inoperative anti-afterfire solenoid.
  6. Pour a small quantity of gasoline through the spark plug hole to test if fuel is reaching combustion chamber.

Source: Briggs & Stratton service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.