Home›Repair guides›Briggs & Stratton›Replacing Solenoid

Briggs & Stratton — Replacing Solenoid

Repair & overhaul · Starter solenoid

From a Briggs & Stratton service manual — check it applies to your exact model before use.

Browse Briggs & Stratton generators & specs →

Procedure

  1. Remove nut and field coil wire from stud terminal.
  2. Remove solenoid mounting nuts and solenoid.
  3. Lift solenoid to disengage drive lever from plunger — hold starter vertically with drive housing side down.
  4. Engage flats on plunger with fork in drive lever and assemble solenoid to starter; torque nuts to 8.0 Nm (70 in. lbs.).
  5. Install field coil wire and nut; torque nut to 10.0 Nm (90 in. lbs.).
  6. Install starter motor; torque screws to 40.0 Nm (30 ft. lbs.).

Specs & values

  • Small hole in rubber dust cover must face starter

Source: Briggs & Stratton service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.