Briggs & Stratton — To Adjust Remote Choke Control
Adjustments
From a Briggs & Stratton owner's manual — check it applies to your exact model before use.
Browse Briggs & Stratton generators & specs →
Before you start
- Prevent unintentional starting. Remove spark plug wires and disconnect battery at negative terminal before adjustments.
Procedure
- Remove air cleaner.
- Move choke control to CHOKE or START position (carburetor choke should be completely closed).
- If not, loosen casing clamp screw.
- Move casing, wire and engine choke lever in direction shown until choke is completely closed.
- Tighten casing clamp screw. Replace air cleaner.
Source: Briggs & Stratton owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.