Home›Repair guides›Briggs & Stratton›To Remove, Clean and Replace the Air Cleaner

Briggs & Stratton — To Remove, Clean and Replace the Air Cleaner

Maintenance

From a Briggs & Stratton service manual — check it applies to your exact model before use.

Browse Briggs & Stratton generators & specs →

Procedure

  1. Remove the thumb nut and slide the entire cleaner over the rod
  2. Remove cover and filter and pour out oil
  3. Wash the outside of the filter element with a rag or brush dipped in gasoline; do not submerge
  4. Clean bowl and cover by submerging in gasoline and wipe dry
  5. Replace parts; fill cleaner with oil of the same viscosity as used in the crankcase up to the level marked on the cleaner bowl

Source: Briggs & Stratton service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.