Manufacturer-documented fuel consumption for 60 5–10 kW Diesel generator sets — median 0.63 gal/h at full load, 0.40 gal/h at half load.

Compare 5–10 kW Diesel generator specs side-by-side →

Consumption by model

60
ModelkWgal/h @ 50%gal/h @ 100% Tank (L)Runtime @ 50% (h)
Cummins/Onan 5.0 MDKUB50.370.55——
Kohler 5EFKOD50.290.50——
Kohler 5EOZ50.290.45——
Kohler 6RFOY50.260.50——
Northern Lights NL67350.070.08——
Lister Petter HSL 85—0.4066—
Cummins/Onan 6 HDKAL-760.510.90——
Cummins/Onan 6 HDKAL-960.510.90——
Cummins/Onan 6.0 MDKUB60.370.55——
Cummins/Onan RV QD 600060.300.40——
Generac MLT4060KVLED6—0.59214—
Isuzu 3CA160.290.57——
Kohler 6EKOD60.290.50——
Kohler 6ROY60.260.50——
Magnum MLT30606—0.47114—
Northern Lights M67360.070.31——
Northern Lights NL7536—0.18——
Stadco CP660.400.80——
Cummins/Onan 7.0HDKBL71.500.74——
Kohler 7EFKOZD70.400.69——
Kohler 7EFOZD70.400.66——
Kubota J1077—0.7137—
Aurora Generators AGi6Y70.240.354550.6
Stadco CP770.400.80——
Generac MLG 870.320.6311493.9
Cummins/Onan 7.5 HDKAL-180.510.90——
Cummins/Onan 7.5 HDKAL-280.510.90——
Cummins/Onan 7.5 HDKAL-380.510.90——
Cummins/Onan 7.5 HDKAL-580.510.90——
Cummins/Onan 7.5 MDKWB80.370.55——
FG Wilson P7.5-2S80.400.664530.0
FG Wilson P7.5-4S8—0.5862—
Generac QUIETPACT 7580.450.78——
FG Wilson K9.5-18—0.6662—
Aqt Generators KU-108—0.65100—
Cummins/Onan 8HDKAG80.551.03——
Cummins/Onan MDKAL80.370.69——
Cummins/Onan MDKB80.260.45——
Cummins/Onan RV QD 800080.300.40——
Kohler 10RFOY80.260.50——
Kubota GL6000-AUS8—0.6328—
Magnum MLT 40808—0.47114—
Perkins 403D-1180.450.53680400.0
Simson-Maxwell SKW8 T6-T48—0.92——
Kubota GL 700080.850.63288.8
FG Wilson DCP-1080.341.656247.7
Kohler 8.5EFOZ80.450.66——
Kohler 9EKOZD80.400.69——
Kohler 9EOZD80.400.66——
Aurora Generators AGi8Y90.240.354550.6
Perkins 403A-11G191.802.60608.8
Cummins/Onan 9.0 MDKWB90.370.55——
FG Wilson K10-190.59—5123.0
Generac MLG8K91.322.65——
Kohler 9EFKOZD90.500.90——
Kohler 9EFOZ90.450.66——
Northern Lights M773L90.370.72——
Northern Lights NL773LW490.130.19——
Generac MLT3060M9—0.47114—
Generac MLT4060MV9—0.59216—

Figures from each model’s own manufacturer documentation (spec sheets and manuals); runtime = documented tank capacity ÷ consumption at 50% load. Verify against the datasheet for your exact configuration.

Common questions

How much fuel does a 5–10 kW Diesel generator use?

Across 59 models with manufacturer data, full-load consumption runs 0.08–2.65 gal/h (median 0.63); at 50% load the median is 0.40 gal/h.

How long will a 5–10 kW Diesel generator run on a full tank?

At 50% load, documented tank sizes give 8.8–400.0 hours (median 47.7 h) across 9 models.