Kohler 15RES Generator Set

The Kohler 15RES is a 13 kW (13 kVA) Natural Gas / LP Vapor standby generator set powered by a General Motors Vortec DOHC engine. It is available at 120/240 V, single-phase, 60 Hz and rated 63 A. It holds about 3.5 L (0.9 gal) of oil and 3.3 L (0.9 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses battery rated 525 CCA at 12 V. The set measures 1850×861×935 mm (72.8×33.9×36.8 in), weighs about 465 kg (1025 lb) and produces 65 dBA at 7 m.

13 kW
Standby
1.6 L
Displacement
3.5 L
Oil capacity
5
Document types

How to read your Kohler serial & model number →

Typical fuel consumption for 15–20 kW Bi-Fuel (NG/LP) generators →

Compare with other 15–20 kW Bi-Fuel (NG/LP) generators →

Service parts for the 15RES

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Oil system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelNatural Gas / LP Vapor
Frequency60.0 Hz
Standby power13 kW
Standby kVA13
ControllerADC 2100, ADC 2100 Digital
Oil capacity3.5 L
Alternator4H7
Voltage options120/240 V
PhaseSingle
Rated current63 A
Battery cranking525 CCA
Battery voltage12 V
Coolant capacity3.3 L
Max ambient40 °C
Dimensions (L×W×H)1850×861×935 mm
Dry weight465 kg
Sound level65.0 dBA @ 7 m

Engine

General Motors Vortec DOHC
Displacement1.6 L
Rated speed1800 rpm

Maintenance & consumables

for the General Motors Vortec DOHC
ItemSpecCapacityPart #Interval
Air filterElement, air cleaner×1GM16944 Amazon $71.53 eBay $49.68
Fuel filter
Oil filterCartridge×1GM28351 Amazon $25.85 eBay $19.46
Battery525 CCA, 12 V DC
Belt
Coolant11.5 L800 hr
Oil3.5 L200 hr
Spark plug800 hr

Fault codes

16
CodeNameMeaningSeverityAction
AFAuxiliary faultFMI 2, SPN 0x02BD
CCCrank cycle
CO-3Fault displayed if the CO parameter is set incorrectlyShutdown
CO-6Fault displayed if the CO parameter is set incorrectlyShutdown
HBHigh battery voltageFMI 0, SPN 0x00A8
HEHigh engine tempFMI 0, SPN 0x006E
LBLow battery voltageFMI 1, SPN 0x00A8
LCLLow coolant levelFMI 1, SPN 0x006F
LOCLoss of coolantFMI 1, SPN 0x006F
LOPLow oil pressureFMI 1, SPN 0x0064
OCOvercrankFMI 0, SPN 0x068B
OFOverfrequencyFMI 0, SPN 0x0984
OSOverspeedFMI 0, SPN 0x00BE
OUOvervoltageFMI 0, SPN 0x0988
UFUnderfrequencyFMI 1, SPN 0x0984
UUUndervoltageFMI 1, SPN 0x0988

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
ADC-RES Controller Configuration (Cn setting) adjustment

⚠ The controller automatically exits configuration mode without saving changes after about 1 minute if no buttons are pressed.

  1. Enter the configuration mode while the engine is not running by following the Figure 26 sequence.
  2. Step through the parameters to the communication setting Cn parameter.
  3. Use the up and down arrow buttons to change the Cn setting to Cn01, if necessary.
  4. Press to SAVE CHANGES (YES) before exiting the configuration mode.
  5. Move the generator set master switch to OFF/RESET.
Controller Configuration adjustment

⚠ Be sure to save the new settings immediately before exiting the configuration mode; changes are lost if the controller times out (about 1 minute).

  1. Hold the Select button and move the master switch to RUN to enter configuration mode.
  2. Press the down arrow key then the up arrow key 3 times to enter configuration mode (password).
  3. Set the voltage/frequency parameter Uu for the model.
  4. Set the unit configuration parameter Uc (marine, standby, mobile).
  5. Set the engine type parameter Ec.
  6. Press the up arrow at the Adnc display to enter advanced configuration mode.
  7. Set the engine data input type Ed.
  8. Set the battery voltage Bt (12 or 24 VDC).
  9. Set the communications parameter Cn.
  10. Enter save mode and save your settings before exiting.
Output Voltage and Frequency Adjustment adjustment

⚠ The generator set must be running during these adjustments.

⚠ The engine speed (frequency) adjustment menus are not accessible on models with mechanical governors.

Tools: multimeter

  1. Move the master switch to RUN; the engine starts and runtime hours display.
  2. Hold the Select button about 5 seconds until the program version number displays.
  3. Press the down arrow key then the up arrow key 3 times to enter adjustment mode.
  4. 1P: adjust voltage coarse in large increments (approximately 5-7 volts per step).
  5. 2P: adjust voltage fine in smaller increments (approximately 0.5-0.7 volts per step).
  6. Adjust voltage stability (gain) coarse and fine.
  7. 3P: set volts/Hz (00=low, 09=high).
  8. 4P: adjust engine governor speed coarse and fine.
  9. 5P: adjust engine governor stability (gain) coarse and fine.
  10. Enter SAVE mode and save settings before exiting the adjustment mode.
Network Bridge Diagnostics diagnostic
  1. Check the network LEDs on the RJ45 connector for Ethernet network communication.
  2. Check the STAT LED; if not lit, check connections and the engine starting battery.
  3. Check the TX and RX LEDs for CAN data transmission and reception.
  4. If neither the TX nor the RX LED flashes, check bridge power, connections, and settings.
  5. If only one of the TX or RX LEDs flashes, check the connected devices on the generator set (CAN) side.
15/30RES and 15/30RYG Bridge Installation (GM62630-KP2) installation
  1. Remove the junction box panel to gain access to the inside of the junction box.
  2. Drill two 4.8 mm (3/16 in.) mounting holes in the top of the junction box.
  3. Install network bridge GM58703 inside the junction box using two screws M7985A-0410-20, washers M125A-04-80, and nuts M934-04-50.
  4. Proceed to Section 6, Network Bridge Connection.
15/30RESA and 15/30REYG Bridge Installation (GM62630-KP4) installation
  1. Remove the junction box panel to gain access to the inside of the junction box.
  2. Drill two 4.8 mm (3/16 in.) mounting holes in the top of the junction box.
  3. Install network bridge GM58703 inside the junction box using two screws M7985A-0410-20, washers M125A-04-80, and nuts M934-04-50.
  4. Proceed to Section 6, Network Bridge Connection.
17/18RES Bridge Installation (GM62630-KP1) installation
  1. Open the enclosure and remove the front panel to access the controller junction box. Cover internal components.
  2. Drill a hole for the customer-supplied Ethernet cable at the location shown.
  3. Drill a 38.1 mm (1.5 in.) hole in the bottom of the junction box. Insert bushing X-634-28.
  4. Route connector P21 of Y-harness GM62626 through this opening.
  5. Drill two 4.8 mm (3/16 in.) mounting holes in the front panel at the locations shown.
  6. Use two screws M7985A-04010-20, washers X-6278-8, and nuts M934-04-50 to mount network bridge GM58703.
  7. Proceed to Section 6, Network Bridge Connection.
8.5/12RES Bridge Installation (GM62630-KP3) installation
  1. Remove existing junction box panel GM60625. Save the hardware and seal for reuse.
  2. Mount network bridge GM58703 onto the new panel using two screws X-51-15, washers M125A-04-80, and nuts M934-04-50.
  3. Install new J-box panel GM66795 as shown. Use the existing hardware and seal X-6422-31.
  4. Affix decal GM54820 in the location shown.
  5. Proceed to Section 6, Network Bridge Connection.
Assign Bridge IP Address installation

Tools: DeviceInstaller software

  1. Launch DeviceInstaller from the Windows Start button.
  2. In the DeviceInstaller menu, click View then Details.
  3. Click the Search button on the toolbar.
  4. Find the device whose hardware address matches the MAC address printed on the network bridge label.
  5. Click the Assign IP button in the toolbar.
  6. If no IP address is assigned, enter the bridge's hardware (MAC) address and click Next.
  7. Select Assign a Specific IP Address and click Next.
  8. Type the bridge IP address, subnet mask, and default gateway in dotted decimal notation. Click Next.
  9. Click the Assign button to assign the IP settings.
  10. Click the Finish button to close the Wizard.
Controller Replacement installation

⚠ Disconnect the battery cables before working on the generator set; remove the negative lead first and reconnect it last.

Tools: multimeter, personal computer with Program Loader Software

  1. Record generator set information required for configuration: model, market, voltage, frequency, phases, battery voltage.
  2. Place the generator set master switch in the OFF position.
  3. Disconnect power to the battery charger, if equipped.
  4. Disconnect the engine starting battery(ies), negative lead first.
  5. Open the junction box; disconnect the controller at P1, J15, and J16.
  6. Models ECD/EFCD, EGD/EFGD, EGZD only: disconnect the CO sensor harness at the 4-pin connector.
  7. Remove four controller mounting screws and remove the old controller.
  8. ECD/EFCD, EGD/EFGD, EGZD only: install CO sensor module assembly GM46362 on the back of the new controller GM47982.
  9. Install the new controller and secure with the mounting screws.
  10. Reconnect the P1, J15, and J16 connectors; connect the CO sensor harness on applicable models.
  11. Models 10/13/15EG, 10/13/15ERG, 15/30RES, 15/30RYG with S/N before 2053692: cut a 1-in. section of the gray/orange lead entering pin 9 at the ECM connector.
  12. Check that the generator set master switch is in the OFF position.
  13. Reconnect the engine starting battery, negative lead last.
  14. Reconnect power to the battery charger, if equipped.
  15. Check the controller application software version and load the latest application code if necessary.
DeviceInstaller Software Installation Procedure installation

Tools: OnCue software CD-ROM

  1. Insert the OnCue software CD-ROM into your PC's CD drive and wait for the opening window.
  2. Click on DeviceInstaller Software. A new window will open.
  3. Click on the Installer.msi file. The DeviceInstaller Setup Wizard will start.
  4. Read the information on the screen and click Next.
  5. Choose the installation directory, normally C:\Program Files. Click Next.
  6. Choose Everyone or Just me for multiple PC users. Click Next.
  7. Continue to follow the on-screen instructions to install DeviceInstaller software.
Installation Procedure installation

⚠ Accidental starting can cause severe injury or death. Disconnect the battery cables, negative lead first.

⚠ Hazardous voltage. Disconnect all power sources before opening the enclosure.

  1. Place the generator set master switch in the OFF position.
  2. Disconnect the power to the battery charger, if equipped.
  3. Disconnect the generator set engine starting battery(ies), negative lead first.
  4. Determine whether the network bridge will be mounted inside the enclosure or in a remote location.
  5. For a remote location, find a protected location; do not install the bridge outdoors.
  6. Maximum cable length between the network bridge and the controller is 36.6 m (120 ft.).
  7. Proceed to the bridge mounting instructions for your generator set model (Figure 8).

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
100 VAC11Ph, 2WUu00; 60 Hz
100 VAC11Ph, 3WUu00; 60 Hz
100/200 VAC11Ph, 3WUu08; 60 Hz
110 VAC11Ph, 2WUu05; 50 Hz
110 VAC11Ph, 3WUu05; 50 Hz
110/190 VAC3WyeUu17; 50 Hz
110/220 VAC11Ph, 3WUu07; 50 Hz
110/220 VAC1DoglegUu07; 50 Hz
110/220 VAC3DeltaUu15; 50 Hz
115 VAC11Ph, 2WUu05; 50 Hz
115/200 VAC3WyeUu23; 50 Hz
115/230 VAC11Ph, 3WUu02; 50 Hz
115/230 VAC1DoglegUu06; 50 Hz
115/230 VAC3DeltaUu14; 50 Hz
120 VAC11Ph, 2WUu00; 60 Hz
120 VAC11Ph, 3WUu00; 60 Hz
120/208 VAC3WyeUu11; 60 Hz
120/240 VAC11Ph, 3WUu01; 60 Hz
120/240 VAC1DoglegUu01; 60 Hz
120/240 VAC3DeltaUu10; 60 Hz
127/220 VAC3WyeUu16; 60 Hz
139/240 VAC3WyeUu10; 60 Hz
220 VAC11Ph, 2WUu12; 50 Hz
220/380 VAC3WyeUu19; 60 Hz
230 VAC11Ph, 2WUu02; 50 Hz
230/400 VAC3WyeUu03; 50 Hz
240 VAC11Ph, 2WUu13; 50 Hz
240/416 VAC3WyeUu20; 60 Hz
277/480 VAC3WyeUu04; 60 Hz

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Kohler 15RES?

The Kohler 15RES is rated 13 kW standby (13.0 kVA).

Which engine powers the Kohler 15RES?

The Kohler 15RES is powered by the General Motors Vortec DOHC engine.

What fuel type does the Kohler 15RES take?

The Kohler 15RES runs on Natural Gas / LP Vapor.

Which alternator is fitted to the Kohler 15RES?

The Kohler 15RES uses a 4H7 alternator.

Which oil filter part number does the Kohler 15RES take?

The Kohler 15RES uses oil filter part number GM28351.

What air filter does the Kohler 15RES use?

The Kohler 15RES uses air filter part number GM16944.

Troubleshooting

1

Symptoms & remedies

SymptomRemedy
Battery short circuitsDisconnect the battery before generator set installation or maintenance. Remove all jewelry before servicing the equipment. Use tools with insulated handles. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

13
Part #DescriptionQtySystem
359422Washer, sealing (30.1 mm OD)1Seal Amazon eBay
364345Switch, assembly pressure1Sensor Amazon eBay
365499O-ring, ISO 6149 (11.3 mm ID)2Seal Amazon eBay
GM16944Element, air cleaner1Air filter Amazon $71.53 eBay $49.68
NGE012014Radiator Fan Shroud BoltsBolt Amazon eBay
X-386-109Fuel line, flexible1Hose Amazon eBay
X-422-15Fuel line, flexible1Hose Amazon eBay
X-422-35Fuel line, flexible1Hose Amazon eBay
X-422-38Line, flexible1Hose Amazon eBay
GM36247Exhaust pipe1Service part / kit Amazon eBay
GM58703Assy, J1939/ModBus/Ethernet Converter (network bridge)1Service part / kit eBay
GM66054Decal reminder to check oil level1Service part / kit Amazon eBay
GM66559Lead, oil pressure switch1Service part / kit Amazon eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Standby25%2.50.66
Standby50%3.50.92
Standby75%4.51.19
Standby100%5.71.51

Available documents

Spec sheet (Kohler)Spec sheet — Kohler 15RES (Kohler)Spec sheet — g4108 (Kohler)Reference (Kohler)Owner's manual — tp6344 (Kohler)Owner's manual — tp6726 (Kohler)Parts manual (Kohler)Parts manual — g260412 (Kohler)Service manual — tp6437 (Kohler)Service manual — tp6725 (Kohler)Service manual — tt1364 (Kohler)Service manual — tt1486 (Kohler)
Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter GM16944$49.68
Oil filter GM28351$19.46
2 priced items$69.14