Home›Repair guides›Kohler›Assign Bridge IP Address

Kohler — Assign Bridge IP Address

Installation · Network bridge / DeviceInstaller

From a Kohler service manual covering: 12RES, 15RES, 15REYG, 15RYG, 17RES, 18RES, 30 RYG, 30RES, 30REYG, 8.5RES. Check it applies to your exact model before use.

Applies to: Kohler 12RES, Kohler 15RES, Kohler 15REYG, Kohler 15RYG, Kohler 17RES, Kohler 18RES, Kohler 30 RYG, Kohler 30RES, Kohler 30REYG, Kohler 8.5RES

Procedure

  1. Launch DeviceInstaller from the Windows Start button.
  2. In the DeviceInstaller menu, click View then Details.
  3. Click the Search button on the toolbar.
  4. Find the device whose hardware address matches the MAC address printed on the network bridge label.
  5. Click the Assign IP button in the toolbar.
  6. If no IP address is assigned, enter the bridge's hardware (MAC) address and click Next.
  7. Select Assign a Specific IP Address and click Next.
  8. Type the bridge IP address, subnet mask, and default gateway in dotted decimal notation. Click Next.
  9. Click the Assign button to assign the IP settings.
  10. Click the Finish button to close the Wizard.

Tools required

  • DeviceInstaller software Amazon

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Full service-parts list: Kohler 12RES →, Kohler 15RES →, Kohler 15REYG →, Kohler 15RYG →, Kohler 17RES →, Kohler 18RES →, Kohler 30 RYG →, Kohler 30RES →, Kohler 30REYG →, Kohler 8.5RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.