Home›Kohler›Kohler 15RYG

Kohler 15RYG Generator Set

The Kohler 15RYG is a 15 kW Gasoline standby generator set powered by a General Motors 1.6L engine. It operates at 60 Hz.

15 kW
Standby
1.6 L
Displacement
4
Document types

How to read your Kohler serial & model number →

Compare with other 15–20 kW Gasoline generators →

Service parts for the 15RYG

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required
3321143Air filtersee priceAmazon

Fuel system

1 required
3342209Fuel filtersee priceAmazon

Oil system

1 required

Belts

1 required
3343634Beltsee priceAmazon

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelGasoline
Frequency60.0 Hz
Standby power15 kW

Engine

General Motors 1.6L
Displacement1.6 L

Maintenance & consumables

for the General Motors 1.6L
ItemSpecCapacityPart #Interval
Air filterELEMENT, FLTR, PRIMARY (air)3321143 Amazon eBay
Fuel filterFILTER, FUEL3342209 Amazon eBay
Oil filterFILTER, OIL (AC-DELCO)3342201 Amazon
BatteryInspect Battery case for damage—1250 hr
BeltBELT, GM 1.6L FAN POLY 6-V 39 in3343634 Amazon eBay
CoolantChange coolant—500 hr
OilChange engine oil and filter—1000 hr
Spark plugReplace at required intervals per maintenance schedule—

Fault codes

16
CodeNameMeaningSeverityAction
AFAuxiliary faultFMI 2, SPN 0x02BD
CCCrank cycle
CO-3Fault displayed if the CO parameter is set incorrectlyShutdown
CO-6Fault displayed if the CO parameter is set incorrectlyShutdown
HBHigh battery voltageFMI 0, SPN 0x00A8
HEHigh engine tempFMI 0, SPN 0x006E
LBLow battery voltageFMI 1, SPN 0x00A8
LCLLow coolant levelFMI 1, SPN 0x006F
LOCLoss of coolantFMI 1, SPN 0x006F
LOPLow oil pressureFMI 1, SPN 0x0064
OCOvercrankFMI 0, SPN 0x068B
OFOverfrequencyFMI 0, SPN 0x0984
OSOverspeedFMI 0, SPN 0x00BE
OUOvervoltageFMI 0, SPN 0x0988
UFUnderfrequencyFMI 1, SPN 0x0984
UUUndervoltageFMI 1, SPN 0x0988

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
ADC-RES Controller Configuration (Cn setting) adjustment

⚠ The controller automatically exits configuration mode without saving changes after about 1 minute if no buttons are pressed.

  1. Enter the configuration mode while the engine is not running by following the Figure 26 sequence.
  2. Step through the parameters to the communication setting Cn parameter.
  3. Use the up and down arrow buttons to change the Cn setting to Cn01, if necessary.
  4. Press to SAVE CHANGES (YES) before exiting the configuration mode.
  5. Move the generator set master switch to OFF/RESET.
Controller Configuration adjustment

⚠ Be sure to save the new settings immediately before exiting the configuration mode; changes are lost if the controller times out (about 1 minute).

  1. Hold the Select button and move the master switch to RUN to enter configuration mode.
  2. Press the down arrow key then the up arrow key 3 times to enter configuration mode (password).
  3. Set the voltage/frequency parameter Uu for the model.
  4. Set the unit configuration parameter Uc (marine, standby, mobile).
  5. Set the engine type parameter Ec.
  6. Press the up arrow at the Adnc display to enter advanced configuration mode.
  7. Set the engine data input type Ed.
  8. Set the battery voltage Bt (12 or 24 VDC).
  9. Set the communications parameter Cn.
  10. Enter save mode and save your settings before exiting.
Output Voltage and Frequency Adjustment adjustment

⚠ The generator set must be running during these adjustments.

⚠ The engine speed (frequency) adjustment menus are not accessible on models with mechanical governors.

Tools: multimeter

  1. Move the master switch to RUN; the engine starts and runtime hours display.
  2. Hold the Select button about 5 seconds until the program version number displays.
  3. Press the down arrow key then the up arrow key 3 times to enter adjustment mode.
  4. 1P: adjust voltage coarse in large increments (approximately 5-7 volts per step).
  5. 2P: adjust voltage fine in smaller increments (approximately 0.5-0.7 volts per step).
  6. Adjust voltage stability (gain) coarse and fine.
  7. 3P: set volts/Hz (00=low, 09=high).
  8. 4P: adjust engine governor speed coarse and fine.
  9. 5P: adjust engine governor stability (gain) coarse and fine.
  10. Enter SAVE mode and save settings before exiting the adjustment mode.
Network Bridge Diagnostics diagnostic
  1. Check the network LEDs on the RJ45 connector for Ethernet network communication.
  2. Check the STAT LED; if not lit, check connections and the engine starting battery.
  3. Check the TX and RX LEDs for CAN data transmission and reception.
  4. If neither the TX nor the RX LED flashes, check bridge power, connections, and settings.
  5. If only one of the TX or RX LEDs flashes, check the connected devices on the generator set (CAN) side.
15/30RES and 15/30RYG Bridge Installation (GM62630-KP2) installation
  1. Remove the junction box panel to gain access to the inside of the junction box.
  2. Drill two 4.8 mm (3/16 in.) mounting holes in the top of the junction box.
  3. Install network bridge GM58703 inside the junction box using two screws M7985A-0410-20, washers M125A-04-80, and nuts M934-04-50.
  4. Proceed to Section 6, Network Bridge Connection.
15/30RESA and 15/30REYG Bridge Installation (GM62630-KP4) installation
  1. Remove the junction box panel to gain access to the inside of the junction box.
  2. Drill two 4.8 mm (3/16 in.) mounting holes in the top of the junction box.
  3. Install network bridge GM58703 inside the junction box using two screws M7985A-0410-20, washers M125A-04-80, and nuts M934-04-50.
  4. Proceed to Section 6, Network Bridge Connection.
17/18RES Bridge Installation (GM62630-KP1) installation
  1. Open the enclosure and remove the front panel to access the controller junction box. Cover internal components.
  2. Drill a hole for the customer-supplied Ethernet cable at the location shown.
  3. Drill a 38.1 mm (1.5 in.) hole in the bottom of the junction box. Insert bushing X-634-28.
  4. Route connector P21 of Y-harness GM62626 through this opening.
  5. Drill two 4.8 mm (3/16 in.) mounting holes in the front panel at the locations shown.
  6. Use two screws M7985A-04010-20, washers X-6278-8, and nuts M934-04-50 to mount network bridge GM58703.
  7. Proceed to Section 6, Network Bridge Connection.
8.5/12RES Bridge Installation (GM62630-KP3) installation
  1. Remove existing junction box panel GM60625. Save the hardware and seal for reuse.
  2. Mount network bridge GM58703 onto the new panel using two screws X-51-15, washers M125A-04-80, and nuts M934-04-50.
  3. Install new J-box panel GM66795 as shown. Use the existing hardware and seal X-6422-31.
  4. Affix decal GM54820 in the location shown.
  5. Proceed to Section 6, Network Bridge Connection.
Assign Bridge IP Address installation

Tools: DeviceInstaller software

  1. Launch DeviceInstaller from the Windows Start button.
  2. In the DeviceInstaller menu, click View then Details.
  3. Click the Search button on the toolbar.
  4. Find the device whose hardware address matches the MAC address printed on the network bridge label.
  5. Click the Assign IP button in the toolbar.
  6. If no IP address is assigned, enter the bridge's hardware (MAC) address and click Next.
  7. Select Assign a Specific IP Address and click Next.
  8. Type the bridge IP address, subnet mask, and default gateway in dotted decimal notation. Click Next.
  9. Click the Assign button to assign the IP settings.
  10. Click the Finish button to close the Wizard.
Controller Replacement installation

⚠ Disconnect the battery cables before working on the generator set; remove the negative lead first and reconnect it last.

Tools: multimeter, personal computer with Program Loader Software

  1. Record generator set information required for configuration: model, market, voltage, frequency, phases, battery voltage.
  2. Place the generator set master switch in the OFF position.
  3. Disconnect power to the battery charger, if equipped.
  4. Disconnect the engine starting battery(ies), negative lead first.
  5. Open the junction box; disconnect the controller at P1, J15, and J16.
  6. Models ECD/EFCD, EGD/EFGD, EGZD only: disconnect the CO sensor harness at the 4-pin connector.
  7. Remove four controller mounting screws and remove the old controller.
  8. ECD/EFCD, EGD/EFGD, EGZD only: install CO sensor module assembly GM46362 on the back of the new controller GM47982.
  9. Install the new controller and secure with the mounting screws.
  10. Reconnect the P1, J15, and J16 connectors; connect the CO sensor harness on applicable models.
  11. Models 10/13/15EG, 10/13/15ERG, 15/30RES, 15/30RYG with S/N before 2053692: cut a 1-in. section of the gray/orange lead entering pin 9 at the ECM connector.
  12. Check that the generator set master switch is in the OFF position.
  13. Reconnect the engine starting battery, negative lead last.
  14. Reconnect power to the battery charger, if equipped.
  15. Check the controller application software version and load the latest application code if necessary.
DeviceInstaller Software Installation Procedure installation

Tools: OnCue software CD-ROM

  1. Insert the OnCue software CD-ROM into your PC's CD drive and wait for the opening window.
  2. Click on DeviceInstaller Software. A new window will open.
  3. Click on the Installer.msi file. The DeviceInstaller Setup Wizard will start.
  4. Read the information on the screen and click Next.
  5. Choose the installation directory, normally C:\Program Files. Click Next.
  6. Choose Everyone or Just me for multiple PC users. Click Next.
  7. Continue to follow the on-screen instructions to install DeviceInstaller software.
Installation Procedure installation

⚠ Accidental starting can cause severe injury or death. Disconnect the battery cables, negative lead first.

⚠ Hazardous voltage. Disconnect all power sources before opening the enclosure.

  1. Place the generator set master switch in the OFF position.
  2. Disconnect the power to the battery charger, if equipped.
  3. Disconnect the generator set engine starting battery(ies), negative lead first.
  4. Determine whether the network bridge will be mounted inside the enclosure or in a remote location.
  5. For a remote location, find a protected location; do not install the bridge outdoors.
  6. Maximum cable length between the network bridge and the controller is 36.6 m (120 ft.).
  7. Proceed to the bridge mounting instructions for your generator set model (Figure 8).

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
100 VAC11Ph, 2WUu00; 60 Hz
100 VAC11Ph, 3WUu00; 60 Hz
100/200 VAC11Ph, 3WUu08; 60 Hz
110 VAC11Ph, 2WUu05; 50 Hz
110 VAC11Ph, 3WUu05; 50 Hz
110/190 VAC3WyeUu17; 50 Hz
110/220 VAC11Ph, 3WUu07; 50 Hz
110/220 VAC1DoglegUu07; 50 Hz
110/220 VAC3DeltaUu15; 50 Hz
115 VAC11Ph, 2WUu05; 50 Hz
115/200 VAC3WyeUu23; 50 Hz
115/230 VAC11Ph, 3WUu02; 50 Hz
115/230 VAC1DoglegUu06; 50 Hz
115/230 VAC3DeltaUu14; 50 Hz
120 VAC11Ph, 2WUu00; 60 Hz
120 VAC11Ph, 3WUu00; 60 Hz
120/208 VAC3WyeUu11; 60 Hz
120/240 VAC11Ph, 3WUu01; 60 Hz
120/240 VAC1DoglegUu01; 60 Hz
120/240 VAC3DeltaUu10; 60 Hz
127/220 VAC3WyeUu16; 60 Hz
139/240 VAC3WyeUu10; 60 Hz
220 VAC11Ph, 2WUu12; 50 Hz
220/380 VAC3WyeUu19; 60 Hz
230 VAC11Ph, 2WUu02; 50 Hz
230/400 VAC3WyeUu03; 50 Hz
240 VAC11Ph, 2WUu13; 50 Hz
240/416 VAC3WyeUu20; 60 Hz
277/480 VAC3WyeUu04; 60 Hz

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

How many kW is the Kohler 15RYG?

The Kohler 15RYG is rated 15 kW standby.

Which engine powers the Kohler 15RYG?

The Kohler 15RYG is powered by the General Motors 1.6L engine.

What kind of fuel does the Kohler 15RYG run on?

The Kohler 15RYG runs on Gasoline.

Which oil filter part number does the Kohler 15RYG take?

The Kohler 15RYG uses oil filter part number 3342201.

What fuel filter fits the Kohler 15RYG?

The Kohler 15RYG uses fuel filter part number 3342209.

What air filter does the Kohler 15RYG use?

The Kohler 15RYG uses air filter part number 3321143.

Parts

94
Part #DescriptionQtySystem
3303991INDICATOR, FLTR SERVICE1Sensor Amazon eBay
3317917HOUSING, AIR FLTR1Air filter Amazon eBay
3321143ELEMENT, FLTR, PRIMARY (air)1Air filter Amazon eBay
3322572ELEMENT, FLTR, SAFETY (air)1Air filter Amazon Amazon eBay eBay
3333656GASKET, EXHAUST2Gasket Amazon eBay
3336742STARTER (DELCO TYPE), after S/N 1P6L13151Starter Amazon eBay
3337019SEAL, #10 (fuel tank)1Seal Amazon eBay
3337396GASKET, OIL PUMP1Gasket Amazon eBay
3337398SEAL, OIL PUMP1Seal Amazon eBay
3338688SEAL, OIL FILLER CAP1Seal Amazon eBay
3338710TENSIONER, TIMING BELT1Belt Amazon eBay
3338713THERMOSTAT1Thermostat Amazon eBay
3338758GASKET, OIL PAN1Gasket Amazon eBay
3338767VALVE, OIL FILTER BYPASS1Oil filter Amazon eBay
3338773SEAL, WATER PUMP COVER1Seal Amazon eBay
3338775PUMP, OIL1Pump Amazon eBay
3338777SEAL, OIL PAN DRAIN PLUG1Seal Amazon eBay
3338789GASKET, OIL PRESSURE RELIEF VALVE BORE PLUG1Gasket Amazon eBay
3338793SCREEN, OIL PUMP1Pump Amazon eBay
3339832HOSE, VACUUM 7/32 in1Hose Amazon eBay
3339834GASKET, 4 BOLT THROTTLE BODY1Gasket Amazon eBay
3339836SENSOR-T MAP1Sensor Amazon eBay
3339837GASKET, INTAKE MANIFOLD/ADAPTER1Gasket Amazon eBay
3339839HOSE, BREATHER1Hose Amazon eBay
3339846GASKET, ADAPTER1Gasket Amazon eBay
3339848HOSE, FUEL 3/8 DIA1Hose Amazon eBay
3339856HOSE, MOLDED FUEL1Hose Amazon eBay
3339857HOSE, MOLDED FUEL #21Hose Amazon eBay
3339862SEAL, QUAD MXR ADAPTER 40MM/1001Seal Amazon eBay
3341069SENDER, OIL PRESSURE 12V1Sensor Amazon eBay
3341793HOSE, ENG OUTLET1Hose Amazon eBay
3342201FILTER, OIL (AC-DELCO)1Oil filter Amazon
3342209FILTER, FUEL1Fuel filter Amazon eBay
3342329SEAL, OIL PUMP HOUSING1Seal Amazon eBay
3342331GASKET, PCV TUBE1Gasket Amazon eBay
3342333STARTER (BOSCH TYPE), before S/N 1P6L13151Starter Amazon eBay
3342351SENSOR, CRANKSHAFT POSN1Sensor Amazon eBay
3342352CAP, OIL FILLER (INCLUDES SEAL 3338688)1Seal Amazon eBay
3342356GASKET, CAMSHAFT HOUSING COVER1Gasket Amazon eBay
3342361SEAL, CAMSHAFT1Seal Amazon eBay
3342364SEAL, CAMSHAFT HOUSING COVER BOLT1Seal Amazon eBay
3342365GASKET KIT, CYLINDER HEAD1Gasket Amazon eBay
3342385BELT, TIMING (111 TEETH)1Belt Amazon eBay
3342409SPARK PLUG4Spark plug Amazon eBay
3342410WIRE, SPARK PLUG CYLINDER #1 (435MM)1Spark plug Amazon eBay
3342411WIRE, SPARK PLUG CYLINDER #2 (365MM)1Spark plug Amazon eBay
3342412WIRE, SPARK PLUG CYLINDER #3 (275MM)1Spark plug Amazon eBay
3342413WIRE, SPARK PLUG CYLINDER #4 (185MM)1Spark plug Amazon eBay
3343069GASKET, EXHAUST RING1Gasket Amazon eBay
3343536PUMP, FUEL1Pump Amazon eBay
3343629SENSOR, O2 @ MANIFOLD1Sensor Amazon eBay
3343630SENSOR, O2 POST CAT1Sensor Amazon eBay
3343633ALTERNATOR, GM 1.6L 7SI1Alternator Amazon eBay
3343634BELT, GM 1.6L FAN POLY 6-V 39 in1Belt Amazon eBay
3343652GASKET, EXHAUST MANIFOLD1Gasket Amazon eBay
3343654GASKET, INTAKE MANIFOLD1Gasket Amazon eBay
3343655FITTING, OIL FILTER1Oil filter Amazon eBay
3343659SEAL, CRANKSHAFT REAR OIL1Seal Amazon eBay
3343661SWITCH, ENG OIL PRESSURE INDICATOR1Sensor Amazon eBay
3343668PUMP KIT, WATER (GM 1.6)1Pump Amazon eBay
3343669HOSE, PCV1Hose Amazon eBay
3343670SEAL, VALVE STEM OIL8Seal Amazon eBay
3401090FITTING & GASKET FOR FUEL PUMP1Gasket Amazon eBay
3500656HOSE, WATER, .75 ID1Hose Amazon eBay
600179SENDING UNIT, FUEL LEVEL1Sensor Amazon eBay
600510RADIATOR HOSE, LOWER1Hose Amazon eBay
600580HOSE, 2.00 X 2.50 (air intake)1Hose Amazon eBay FridayParts $687.00
600812HOSE, RADIATOR, UPPER, ATLAS1Hose Amazon eBay KuduParts $465.00
620001HOSE, FUEL, 5/16 ID X 12.00 LG, SAE30R71Hose Amazon eBay
620002HOSE, FUEL, 5/16 ID X 10.00 LG, SAE30R72Hose Amazon eBay
620003HOSE, FUEL, 5/16 ID X 17.00 LG, SAE30R71Hose Amazon eBay
620004HOSE, FUEL, 5/16 ID X 36.00 LG, SAE30R71Hose Amazon eBay
GM28351Filter, oil1Oil filter Amazon eBay $19.46 NAPA $9.09
0A-2General InformationService part / kit Amazon eBay
3318752OVERFLOW BOTTLE KIT1Service part / kit Amazon eBay
3336679-1RADIATOR - OIL COOLER1Service part / kit Amazon eBay
3338701ADJUSTER, HYDRAULIC VALVE LASH8Service part / kit Amazon eBay
3338702SPRING, VALVE (INTAKE AND EXHAUST)8Service part / kit Amazon eBay
3338733RING KIT, PISTON (STD)4Service part / kit Amazon eBay
3338735BEARING KIT, CONNECTING ROD (STD)1Service part / kit Amazon eBay
3339849VALVE, LOCK-OFF (LPG)1Service part / kit Amazon eBay
3339858REGULATOR, ELECTRONIC PRESSURE (EPR)1Service part / kit Amazon eBay
3339870MIXER, CERTIFIED (LPG)1Service part / kit Amazon eBay
3342304FAN, PUSHER 16 in GM 1.6L1Service part / kit Amazon eBay
3342379VALVE, EXHAUST4Service part / kit Amazon eBay
3342380VALVE, INTAKE1Service part / kit Amazon eBay
3342408COIL, IGNITION1Service part / kit Amazon eBay $270.46
3343413CAP, FUEL TANK1Service part / kit Amazon eBay
3343611PULLEY FOR FAN, GM 1.6L1Service part / kit Amazon eBay
3343627THROTTLE BODY, GM 1.6L BOSCH 401Service part / kit Amazon eBay
3343651PLUG, OIL PAN DRAIN1Service part / kit Amazon eBay
3350056MUFFLER - CONVERTER1Service part / kit Amazon eBay
GM36247Exhaust pipe1Service part / kit Amazon eBay
GM58703Assy, J1939/ModBus/Ethernet Converter (network bridge)1Service part / kit eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Reference — tp6481 (Kohler)Owner's manual — tp6197 (Kohler)Parts manual (Kohler)Parts manual — g260412 (Kohler)Parts manual — tp6319 (Kohler)Service manual — tp6437 (Kohler)Service manual — tt1364 (Kohler)Service manual — tt1486 (Kohler)

This page was generated from the 8 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.