The Kohler 15RYG is a 15 kW LP gas or natural gas standby generator set powered by a General Motors 1.6L OHC engine. It operates at 60 Hz. It holds about 3.5 L (0.9 gal) of oil and 11.5 L (3.0 gal) of coolant.

15 kW
Standby
1.6 L
Displacement
3.5 L
Oil capacity
6
Document types

How to read your Kohler serial & model number →

Specifications

FuelLP gas or natural gas
Frequency60.0 Hz
Standby power15 kW
ControllerADC 2100
Oil capacity3.5 L
Alternator2G5

Engine

General Motors 1.6L OHC
Oil capacity3.5 L
Coolant capacity11.5 L
Displacement1.6 L
Rated speed1800 rpm

Maintenance & consumables

for the General Motors 1.6L OHC
ItemSpecCapacityPart #Interval
Air filterInspect and clean×1GM16944 Amazon eBay $49.68 PartsGeek
Oil filter×1GM28351200 hr Amazon eBay $19.46 PartsGeek
Belt×1GM28352 Amazon eBay $35.00 PartsGeek
CoolantFlush the cooling system800 hr
Oil3.5 LGM62348-SKP1-QS200 hr Amazon eBay PartsGeek

Common questions

What is the power rating of the Kohler 15RYG?

The Kohler 15RYG is rated 15 kW standby.

What engine does the Kohler 15RYG use?

The Kohler 15RYG is powered by the General Motors 1.6L OHC engine.

What fuel does the Kohler 15RYG use?

The Kohler 15RYG runs on LP gas or natural gas.

What is the oil capacity of the Kohler 15RYG?

The General Motors 1.6L OHC engine in the Kohler 15RYG has an oil capacity of 3.5 liters.

What alternator does the Kohler 15RYG use?

The Kohler 15RYG uses a 2G5 alternator.

Troubleshooting

4

Symptoms & remedies

SymptomRemedy
Gas fuel leaks can cause an explosion.Check the LPG vapor or natural gas fuel system for leakage by using a soap and water solution with the fuel system test pressurized to 6--8 ounces per square inch (10--14 inches water column). Do not use a soap solution containing either ammonia or chlorine because both prevent bubble formation. A successful test depends on the ability of the solution to bubble.
LPG liquid withdrawal fuel leaks can cause an explosion.Check the LPG liquid withdrawal fuel system for leakage by using a soap and water solution with the fuel system test pressurized to at least 90 psi (621 kPa). Do not use a soap solution containing either ammonia or chlorine because both prevent bubble formation. A successful test depends on the ability of the solution to bubble.
Battery short circuitsDisconnect the battery before generator set installation or maintenance. Remove all jewelry before servicing the equipment. Use tools with insulated handles. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery. Never connect the negative (--) battery cable to the positive (+) connection terminal of the starter solenoid. Do not test the battery condition by shorting the terminals together.
Battery acid cleanupAdd 500 g (1 lb.) of bicarbonate of soda (baking soda) to a container with 4 L (1 gal.) of water and mix the neutralizing solution. Pour the neutralizing solution on the spilled battery acid and continue to add the neutralizing solution to the spilled battery acid until all evidence of a chemical reaction (foaming) has ceased. Flush the resulting liquid with water and dry the area.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

2
Part #DescriptionQtySystem
GM28351Filter, oil1Oil filter Amazon eBay $19.46 PartsGeek
GM36247Exhaust pipe1Service part / kit PartsGeek

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
25%
50%
75%
100%

Available documents

Installation manual — tp6329 (Kohler)Installation manual — tt1364 (Kohler)Installation manual — tt1486 (Kohler)Reference — tp6481 (Kohler)Owner's manual — tp6197 (Kohler)Parts manual (Kohler)Parts manual — g260412 (Kohler)Parts manual — tp6319 (Kohler)Service manual — tp6198 (Kohler)Wiring diagram — tp6437 (Kohler)