Kohler — ADC-RES Controller Configuration (Cn setting)

Adjustments

From a Kohler service manual covering: 12RES, 15RES, 15REYG, 15RYG, 17RES, 18RES, 30 RYG, 30RES, 30REYG, 8.5RES. Check it applies to your exact model before use.

Applies to: Kohler 12RES, Kohler 15RES, Kohler 15REYG, Kohler 15RYG, Kohler 17RES, Kohler 18RES, Kohler 30 RYG, Kohler 30RES, Kohler 30REYG, Kohler 8.5RES

Before you start

  • The controller automatically exits configuration mode without saving changes after about 1 minute if no buttons are pressed.

Procedure

  1. Enter the configuration mode while the engine is not running by following the Figure 26 sequence.
  2. Step through the parameters to the communication setting Cn parameter.
  3. Use the up and down arrow buttons to change the Cn setting to Cn01, if necessary.
  4. Press to SAVE CHANGES (YES) before exiting the configuration mode.
  5. Move the generator set master switch to OFF/RESET.

Specs & values

  • Cn01 = J1939 communication enabled, sleep mode disabled (default for code version 1.13 or higher)
  • Cn00 = no J1939 communication, sleep mode enabled

Full service-parts list: Kohler 12RES →, Kohler 15RES →, Kohler 15REYG →, Kohler 15RYG →, Kohler 17RES →, Kohler 18RES →, Kohler 30 RYG →, Kohler 30RES →, Kohler 30REYG →, Kohler 8.5RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.