Procedure

  1. Connect the N2, PF3A, white, green, and yellow leads of network bridge harness GM85426 to the generator set terminal block.
  2. Connect 8-pin connector P1 of network bridge harness GM85426 to P36 on the bridge.
  3. Proceed to the instructions for All Models.

Full service-parts list: Kohler 12RES →, Kohler 15RES →, Kohler 15REYG →, Kohler 15RYG →, Kohler 17RES →, Kohler 18RES →, Kohler 30 RYG →, Kohler 30RES →, Kohler 30REYG →, Kohler 8.5RES →

Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.