Kohler — 15/30RES and 15/30RYG Bridge Installation (GM62630-KP2)
Installation · Network bridge GM58703
From a Kohler service manual covering: 12RES, 15RES, 15REYG, 15RYG, 17RES, 18RES, 30 RYG, 30RES, 30REYG, 8.5RES. Check it applies to your exact model before use.
Applies to: Kohler 12RES, Kohler 15RES, Kohler 15REYG, Kohler 15RYG, Kohler 17RES, Kohler 18RES, Kohler 30 RYG, Kohler 30RES, Kohler 30REYG, Kohler 8.5RES
Procedure
- Remove the junction box panel to gain access to the inside of the junction box.
- Drill two 4.8 mm (3/16 in.) mounting holes in the top of the junction box.
- Install network bridge GM58703 inside the junction box using two screws M7985A-0410-20, washers M125A-04-80, and nuts M934-04-50.
- Proceed to Section 6, Network Bridge Connection.
Specs & values
- 4.8 mm (3/16 in.) mounting holes
Full service-parts list: Kohler 12RES →, Kohler 15RES →, Kohler 15REYG →, Kohler 15RYG →, Kohler 17RES →, Kohler 18RES →, Kohler 30 RYG →, Kohler 30RES →, Kohler 30REYG →, Kohler 8.5RES →
Source: Kohler service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.