Fischer Panda Panda 15000 Generator Set

The Fischer Panda Panda 15000 is a generator set powered by a Kubota D902 engine. It is available at 230 V and 120 V. It holds about 3.7 L (1.0 gal) of oil and 4.1 L (1.1 gal) of coolant. The same D902 engine also powers generator sets from Atlas Copco, Kubota, MQ Power and Vmac.

0.898 L
Displacement
3.7 L
Oil capacity
2
Document types

Service parts for the Panda 15000

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Standby kVA15
Oil capacity3.7 L
AlternatorFischer Panda Panda i-generator
Voltage options230 V, 400 V, 50 V, 60 V, 120 V, 240 V

Engine

Kubota D902
Oil capacity3.7 L
Coolant capacity4.1 L
Displacement0.898 L
AspirationWater cooled
Rated speed3600 rpm

Filters for the Kubota D902

5

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:

SystemFilterDescriptionCross-references
Oil filterP550162Lube Filter, Spin-On Full FlowKUBOTA 1524132040, KUBOTA 1542132090, NAPA 1301, NAPA 1334 FridayParts $10.50
Oil filterP550318Lube Filter, Spin-On Full FlowKUBOTA 1505632432, KUBOTA 1609831291, NAPA 21521, NAPA H10W02 FridayParts $23.27
Fuel filterP550127Fuel Filter, Spin-OnKUBOTA 1522143170, KUBOTA 1522143171, NAPA 3390, WALGAHN-MOTORENTECHN 00811936 KuduParts $16.00
Fuel filterP550012Fuel Filter, In-LineKUBOTA 1258143010, KUBOTA 1258143011, BALDWIN BF840-K1, RENAULT VI 0005490862 KuduParts $13.00 FridayParts $15.50
Fuel / water separatorP551039Fuel Filter, Water Separator Spin-On Twist&DrainNAPA 3192, BALDWIN BF1257, CLUB CAR 102614001, CLUB CAR 102703401 FridayParts $25.40 KuduParts $97.00

Same engine, other brands

4 brands

The Kubota D902 in this set also powers 8 generator sets sold under 4 other brands. Service parts and maintenance intervals for the engine are shared; enclosure, alternator, controller and ratings are not.

BrandModels
Atlas CopcoXAS 110 KD, XAS 48, XAS 48 Kd
KubotaGL 14000, GL14000-USA
MQ PowerTGL12SPX2, TLG-12SPX3
VmacMF-KUBOTA M200077

Maintenance & consumables

for the Kubota D902
ItemSpecCapacityPart #Interval
Air filterRG158429301000 hr Amazon eBay $15.50 PartsGeek $23.97 FridayParts $16.50
Fuel filter—500 hr
Oil filter—1000 hr
Battery—24000 hr
Belt—500 hr
Coolant5.0—24000 hr
Coolant filter—
Fueldrain from tank and refill with a protective mixture (90 % diesel and 10 % preservative oil) (level to full).—
Oil3.6—100 hr
Spark plug—1000 hr

Compatible filters for the Kubota D902 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.

  • Fuel filter: Kubota 1258143013 Kubota 1522143081 Donaldson P550012 Donaldson P551039 Donaldson P550127
  • Oil filter: Kubota 7665025430 Kubota 1641432434 Donaldson P550162 Donaldson P550318 Wix 51334

Service intervals

9
ItemActionHoursMonthsNotes
V-beltInspect50 hr
Full inspection after extended downtimeInspect150 hrafter extended downtimes, a full 150 h inspection as per inspection list
V-beltReplace250 hrreplacement interval must never be exceeded
Fuel filterChange300 hrat the very latest, depending on fuel contamination
Fuel filter with sight glassChange300 hrat the latest, depending on fuel pollution
Battery charge status during extended downtimeCheck3 morecharge regularly roughly every 3 months
Battery charge status during medium-term downtimeCheck2 morecharge regularly roughly every 2 months
PMGi heat sinksInspect6 moclean with compressed air
Starter batteryCheck2 mocharge at least every 2 months

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

14
TypeItemValueUnitCondition
GapBattery electrolyte level10-15mmabove top of plates
OtherPre-glow timemax. 20secat 20 °C or more approx. 5-6 sec
OtherV-belt tensionapprox. 1cmwhen pushed in with thumb
PressureMax. exhaust back pressure9,3kPaalso printed as 93 Millibar
SpeedIdle running speed2900rpm
SpeedRated speed3000rpm
TemperatureCooling water hose (rubber radiator hose)-40 to +100°Ccontinuous operation
TemperatureCooling water temperature difference between in-flow and returnapprox. 10-18°Cat nominal rating
TemperatureFuel hose-30 to +100°Ccontinuous operation
TemperatureSilicone exhaust hose280°Cmax temperature
TemperatureSilicone web hose280°Cmax temperature
TorqueCylinder head nut torque42mmprinted in table as 42 mm
TorqueMaximum tightening torque for iControl2 connecting bolts1.2Nm
Valve clearanceValve clearance (engine cold)0,2mmengine cold

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantGLYSANTIN PROTECT PLUS / G48Water/antifreeze: 70:30 -20 °C; 65:35 -25 °C; 60:40 -30 °C; 55:45 -35 °C; 50:50 -40 °C
Engine oilSAE10W or SAE10W-30; SAE10W-40API CFbelow 0°C3.7 lbelow 0 °C
Engine oilSAE20 or SAE10W-30; SAE10W-40API CF0°C to 25°C3.7 l0 °C to 25 °C
Engine oilSAE30 or SAE10W-30; SAE10W-40API CFabove 25°C3.7 lover 25 °C
FuelDiesel fuel oilDIN590:1999 or better; DIN590:2009 or better for common rail or particle filterDo not use alternative fuel
GreaseAcid-free and acid-resistant greaseBattery terminals
GreaseHeat resistant grease (Antiseize)Fuel filter sight glass o-ring

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

13
CodeNameMeaningSeverityAction
BATTERY LOWBattery power too lowBattery power too lowShutdownController is completely shut down to prevent battery discharging too much.
FAULT: CYL.HEADCylinder head temperature too highCylinder head temperature too highShutdownAcknowledge with Start/Stop button; controller returns to stand-by mode.
FAULT: EXHAUSTExhaust manifold temperature too highExhaust manifold temperature too highShutdownAcknowledge with Start/Stop button; controller returns to stand-by mode.
FAULT: OILPRESSOil pressure errorOil pressure errorShutdown
FAULT: WINDINGWinding temperature too highWinding temperature too highShutdownAcknowledge with Start/Stop button; controller returns to stand-by mode.
HIGH cylinder head temperatureCylinder head temperature is too highWarning threshold reachedWarning
INIT FAILED!Parameters were not correctly adopted into EEPROMParameters were not correctly adopted into EEPROM when generator type was initialised. Generator type must be reset.ShutdownReset generator type.
Inverter overloadGenerator was overloadedGenerator was overloadedShutdown
Inverter overtempInverter temperature too highInverter temperature too highShutdown
NO CONNECTION BUS ERRORCommunication error on Fischer Panda busCommunication error on Fischer Panda busShutdownSecure generator; check all plug-in connections and cables for firm seating or damage; acknowledge after restoring connection.
OUTOut of range - broken cable on corresponding temperature sensorOUT is output instead of a temperatureShutdownCheck corresponding temperature sensor cable.
PROBLEM WITH FUEL SUPPLY!Fuel supply not suitableFuel supply not suitableShutdown
STARTING FAILSGenerator start has failedGenerator start has failedWarningAcknowledge with cursor-up, cursor-down or Start/Stop button; system returns to stand-by mode.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

10
Checking oil-level maintenance

⚠ Generator and coolant can be hot during and after operation.

Tools: paper towels / cloth, oil dipstick

  1. Place generator level.
  2. Run generator about 10 minutes; wait 3 minutes.
  3. Secure against accidental start; open casing.
  4. Pull oil dipstick, clean, reinsert, wait 10 seconds.
  5. Pull dipstick and read oil level at lower end.
  6. Refill if below 1/3; change oil if below MIN and 150 h or more.
First filling and ventilation of internal cooling water circuit maintenance

⚠ Risk of scalding from hot cooling water.

  1. Fill external expansion tank to max marking; open its cover temporarily.
  2. Open venting screw at internal cooling water pump until bubble-free coolant escapes; close.
  3. Open venting screw at thermostat housing; close when air-free water comes out.
  4. Start generator unloaded for approx. 10 seconds; switch off.
  5. Repeat until no more air comes out; fill expansion tank to max.
  6. Re-ventilate 10 operating hours after first start-up if necessary.
Replacement of engine oil and engine oil filter maintenance

⚠ Used oil is toxic and must be disposed properly.

Tools: open-ended wrench 17 mm, oil filter wrench, container, oil resistant mat, paper towels

  1. Prepare level generator, run warm, wait 3 minutes.
  2. Secure against start, open casing, place mat and container.
  3. Loosen oil filler cap.
  4. Open oil drain screw with 17 mm wrench and drain oil.
  5. Remove oil filter with filter wrench counterclockwise.
  6. Clean filter holder and oil new filter seal.
  7. Screw in new filter by hand; refit drain screw with new sealing.
  8. Fill engine oil, checking level every 2 litres.
  9. Run engine 10 minutes, stop, recheck oil level; clean up.
Replacement of fuel filter maintenance

⚠ A clogged filter causes decreased power output.

  1. Clamp fuel inlet.
  2. Remove hoses from used filter and fit to new filter.
  3. Observe arrow on filter housing for fuel flow direction.
  4. For sight glass type: unscrew housing and filter element counterclockwise.
  5. Screw new element into mount.
  6. Lubricate sight glass O-ring with heat-resistant grease (Antiseize); refit sight glass clockwise.
Replacement of the impeller maintenance

⚠ Impeller is a wearing part.

Tools: multigrip pliers

  1. Close raw water stop cock.
  2. Remove raw water pump cover screws.
  3. Pull impeller from shaft with multigrip pliers; mark position.
  4. Check impeller for damage and replace if necessary.
  5. Lubricate impeller with glycerin or silicone spray.
  6. Fit impeller on shaft in marked position.
  7. Fasten cover with new seal.
Replacing the V-belt at Kubota 02/03/05 series maintenance

⚠ V-belt is a wearing part; replacement interval must never exceed 250 operating hours.

Tools: wrench 12 mm

  1. Loosen fixing screw above alternator with 12 mm wrench.
  2. Loosen fixing screw below alternator.
  3. Push alternator toward thermostat housing.
  4. Replace V-belt with Quad Power XPZ 862.
  5. Tension by pulling back alternator; belt should yield approx. 1 cm.
  6. Retighten screws above and below alternator.
Ventilating the fuel system maintenance

⚠ Prevent escaping fuel running into the capsule.

Tools: spanner 10 mm, spanner 17 mm, cloth

  1. Switch main power OFF.
  2. Press and hold failure bypass switch; fuel pump must be audible.
  3. Open ventilation screw at fuel solenoid valve while button pressed.
  4. Close screw when fuel runs without air bubbles; release button.
  5. Start engine; if it does not start, loosen injection line connecting nut and repeat.
  6. Retighten washers after start; switch main switch OFF.
Activating/deactivating autostart function (iControl2) operation

⚠ Automatic start-up: generator can start automatically.

  1. Access set-up menu by pressing cursor-down after switching on while panda bear is displayed.
  2. Select "Autostart" with cursor buttons; confirm with Start/Stop.
  3. Select "Enable" or "Disable"; confirm with Start/Stop.
  4. Message confirms selection; setting saved to EEPROM; controller shuts down.
  5. Switch controller back on; status "AUTOSTART" or "STANDBY" indicates state.
Priming the fuel system (iControl2) operation
  1. In set-up menu select "Prime fuel"; confirm with Start/Stop.
  2. Press Start/Stop again; fuel pump runs for max. 30 seconds then shuts off.
  3. To switch off manually, confirm "Prime fuel" again and use Start/Stop.
Resetting the service interval (iControl2) operation
  1. In set-up menu select "Service"; confirm with Start/Stop.
  2. Screen shows service information and reset instruction.
  3. Press Start/Stop again to reset interval to original stored interval.
  4. Controller switches off; after restart new value displayed.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
230 V1PMGi out with external PE/N bridgePE,N,LFor RCD protected grid; connect 1:1 to electrical cabinet; test RCD after installation.
230 V1PMGi out without external PEN jumperPE,N,LInternal PE-N bridge installed.
230 V1PMGi with isolation controlPE,N,LExternal or internal PE-N bridge must be disconnected.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What engine does the Fischer Panda Panda 15000 use?

The Fischer Panda Panda 15000 is powered by the Kubota D902 engine.

What's the oil capacity on a Fischer Panda Panda 15000?

The Kubota D902 engine in the Fischer Panda Panda 15000 has an oil capacity of 3.7 liters.

What is the coolant capacity of the Fischer Panda Panda 15000?

The Fischer Panda Panda 15000 cooling system holds 4.1 liters (1.1 US gallons) for the engine, per the manufacturer specification sheet.

What voltage does the Fischer Panda Panda 15000 produce?

The Fischer Panda Panda 15000 is offered in 230 V, 400 V, 50 V, 60 V, 120 V, 240 V.

What alternator does the Fischer Panda Panda 15000 use?

The Fischer Panda Panda 15000 uses a Fischer Panda Panda i-generator alternator.

What oil filter does the Fischer Panda Panda 15000 use?

The Fischer Panda Panda 15000 uses oil filter part numbers KUBOTA 7665025430, KUBOTA 1641432434.

What fuel filter fits the Fischer Panda Panda 15000?

The Fischer Panda Panda 15000 uses fuel filter part numbers KUBOTA 1258143013, KUBOTA 1522143081.

What air filter fits the Fischer Panda Panda 15000?

The Fischer Panda Panda 15000 uses air filter part number RG15842930.

Parts

24
Part #DescriptionQtySystem
100-0245-000Air Filter1Air filter Amazon
100-0247-000Fuel Filter1Fuel filter Amazon eBay
100-0248-000Belt1Belt Amazon eBay
100-025-000Air Filter1Air filter Amazon eBay
100-030-000Oil Filter1Oil filter Amazon eBay
100-0368-000Oil Filter1Oil filter Amazon eBay
100-0369-000Coolant Filter1Coolant filter Amazon eBay
100-0370-000Spark Plug1Spark plug Amazon
100-045-000Fuel Filter1Fuel filter Amazon eBay
100-060-000Coolant Filter1Coolant filter Amazon eBay
100-075-000Belt1Belt Amazon eBay
100-090-000Spark Plug1Spark plug Amazon eBay
100-105-000Spark Plug1Spark plug Amazon eBay
P01-025Air filter mat1Air filter Amazon eBay
P01-026Pull out holder for air filter mat1Air filter Amazon eBay
P01-027Air filter housing with snap fasteners1Air filter Amazon eBay
P01-028Air filter1Air filter Amazon eBay
P01-030Fuel filter with sight glass1Fuel filter Amazon eBay
P01-032Water separator in the fuel supply1Fuel filter Amazon eBay
P01-034Spring, By-Pass Valve1Belt Amazon eBay
P01-036Spark plug1Spark plug Amazon eBay
R1/2Drain Plug (R1/2)Oil filter buy
W0301-00008Starter Key (2 pieces)2Starter Amazon eBay
21.03.10.008PService Kit 8Service part / kit buy

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Available documents

Owner's manual — fischer-panda-15000i-manual (Fischer Panda)Parts manual — CEB8C12E-CFC5-AD6B-E298-8319FC02A9A6 (Fischer Panda)

This page was generated from the 2 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter RG15842930$15.50
1 priced item$15.50