Home›Repair guides›Fischer Panda›First filling and ventilation of internal cooling water circuit

Fischer Panda Panda 15000 — First filling and ventilation of internal cooling water circuit

Maintenance · Cooling system

For the Fischer Panda Panda 15000, from the Fischer Panda owner's manual.

Applies to: Fischer Panda Panda 15000, Fischer Panda Panda 15000i PMS generator, Kubota D902 engine

Before you start

  • Risk of scalding from hot cooling water.

Procedure

  1. Fill external expansion tank to max marking; open its cover temporarily.
  2. Open venting screw at internal cooling water pump until bubble-free coolant escapes; close.
  3. Open venting screw at thermostat housing; close when air-free water comes out.
  4. Start generator unloaded for approx. 10 seconds; switch off.
  5. Repeat until no more air comes out; fill expansion tank to max.
  6. Re-ventilate 10 operating hours after first start-up if necessary.

Specs & values

  • Expansion tank max marking
  • Coolant GLYSANTIN PROTECT PLUS/G48

Full service-parts list: Fischer Panda Panda 15000 →, Fischer Panda Panda 15000i PMS generator →, Kubota D902 engine →

Source: Fischer Panda owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.