Home›Cummins/Onan›Cummins/Onan DGFB

Cummins/Onan DGFB Generator Set

The Cummins/Onan DGFB is a 175 kW (219 kVA) Diesel standby generator set powered by a Cummins/Onan 6CTA8.3 engine. It is available at 12 V, 3-phase and 60 Hz. It holds about 19 L (5.0 gal) of oil and 28 L (7.4 gal) of coolant, with a maximum ambient rating of 40 °C. Starting uses 1 group-4 battery rated 1080 CCA at 12 V. An integrated tank holds 24.8 L (6.6 gal).

175 kW
Standby
8.3 L
Displacement
19.0 L
Oil capacity
4
Document types

How to read your Cummins/Onan serial & model number →

Typical fuel consumption for 175–180 kW Diesel generators →

Compare with other 175–180 kW Diesel generators →

Service parts for the DGFB

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Fuel system

1 required

Oil system

2 required
LS1174sOil filtersee priceAmazon
3377363Oilsee priceAmazon

Belts

1 required

Electrical

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power175 kW
Standby kVA219
Prime power160 kW
EmissionsEPA Nonroad Tier 1
ControllerDetector 7, PCC2100, PowerCommand 2100, PowerCommand PCC 3100, PowerCommand PCC2100
Oil capacity19.0 L
Voltage options110/190 V, 120/208 V, 220/380 V, 240/416 V, 139/240 V, 277/480 V, 347/600 V, 120/240 V
Phase3
Power factor0.8
Battery group4D
Battery cranking1080 CCA
Battery voltage12 Volts DC V
Battery quantity1
Coolant capacity28.0 L
Max ambient40 °C
Wet weight1520 kg
Fuel tank24.8 L

Engine

Cummins/Onan 6CTA8.3
Oil capacity19.0 L
Coolant capacity28.0 L
Displacement8.3 L
AspirationTurbocharged

Filters for the Cummins/Onan 6CTA8.3

8

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

SystemFilterDescriptionCross-references
Oil filterP553000Lube Filter, Spin-On Full FlowCUMMINS 3318853, CUMMINS 3825970, NAPA 1748, NAPA 1748XD FridayParts $125.00
Oil filterP553548Lube Filter, Spin-On CombinationCUMMINS 3919562, CUMMINS 3973686, BALDWIN BD324, LOESING 025227 KuduParts $48.00 FridayParts $49.99
Fuel filterP550440Fuel Filter, Spin-On SecondaryCUMMINS 3831063, CUMMINS 3890707, NAPA 3358, BALDWIN BF788 FridayParts $356.80
Fuel filterP550974Fuel Filter, In-LineCUMMINS 3826094, NAPA 3270, BLAW KNOX 0016481600, PERKINS 102601 FridayParts $356.80
Fuel / water separatorP551329Fuel Filter, Water Separator Spin-On Twist&DrainCUMMINS 11E170210, CUMMINS 3890063, NAPA 3357, BALDWIN BF1280 FridayParts $151.00
Fuel / water separatorP558000Fuel Filter, Water Separator Spin-On Twist&DrainCUMMINS 3308638, CUMMINS 3308683, NAPA 3405, NAPA 3693 KuduParts $24.00 FridayParts $25.66
Coolant filterP554071Coolant Filter, Spin-OnCUMMINS 209604, CUMMINS 209606, NAPA 4071, WALGAHN-MOTORENTECHN 00811412 FridayParts $397.60
Coolant filterP552072Coolant Filter, Spin-On Sca PlusCUMMINS 3100305, CUMMINS 3300900, NAPA 4072, IMPERIAL 04WF2072 buy

Maintenance & consumables

for the Cummins/Onan 6CTA8.3
ItemSpecCapacityPart #Interval
Air filterAF4669 Amazon eBay $225.00
Fuel filter3843760 Amazon eBay $74.95
Oil filterLS1174sLS1174s250 hr Amazon eBay
BatteryB-45B-4550 hr Amazon SinoCMP $1269.00
Belt3911562 Amazon eBay $26.05
Coolant36.0—100 hr
OilCummins Premium Blue 15W406.0 gal3377363 Amazon eBay
Spark plug—1000 hr

Service intervals

40
ItemActionHoursMonthsNotes
Charge air pipingCheck50 hrDaily or after 8 hours
Check Coolant LevelCheck8 hrDaily
Check Fuel LevelCheck8 hrDaily
Check Oil LevelCheck8 hrDaily
Coolant levelCheck8 hrDaily or after 8 hours
Drain Water from Fuel FilterDrain8 hrDaily; drain 1 cup or more of fuel to remove water and sediment.
Engine oil levelCheck8 hrDaily or after 8 hours
Fuel Filter(s)Drain8 hrDrain 1 cup or more of fuel to remove water and sediment. Refer to engine operation and maintenance manual for procedure.
Fuel Tanks (water and sediment)Drain8 hrDrain 1 cup or more of fuel to remove water and sediment.
Fuel levelCheck8 hrDaily or after 8 hours
General genset inspectionInspect8 hrDaily or after 8 hours. Check for oil, fuel, cooling and exhaust system leaks; check exhaust audibly and visually with set running.
Inspect GensetCheck8 hrCheck for oil, fuel, cooling and exhaust system leaks. Check exhaust system audibly and visually with set running and repair any leaks immediately.
Inspect SetInspect8 hrDaily; check for oil, fuel, cooling, and exhaust system leaks.
Oil LevelCheck8 hrKeep oil level near the dipstick high mark without overfilling.
Air CleanerClean50 hrClean if required. Perform more often in dusty conditions.
Air cleaner (clean if required)Clean50 hrWeekly or after 50 hours; perform more often in dusty conditions
Battery charging systemCheck50 hrWeekly or after 50 hours
Check Anti-freeze and DCA ConcentrationCheck50 hrWeekly
Check Battery Charging SystemCheck50 hrWeekly
Check Battery Level and Specific GravityCheck50 hrWeekly
Check Coolant HeaterCheck50 hrWeekly
Check Drive Belt TensionCheck50 hrWeekly; visually check belts for evidence of slippage.
Check Generator Air OutletCheck50 hrWeekly
Coolant heaterCheck50 hrWeekly or after 50 hours
Crankcase OilDrain50 hrFirst service — Break-in: drain and replace the crankcase oil after the first 50 hours of operation on new generator sets.
Crankcase oilChange50 hrFirst service — Drain and replace after first 50 hours of operation on new generator sets.
Drain Exhaust Condensate TrapDrain50 hrWeekly
Drain Water and Sediment from Fuel TanksDrain50 hrWeekly; drain 1 cup or more.
Exhaust condensate trapDrain50 hrWeekly or after 50 hours
Water and sediment from fuel tankDrain50 hrWeekly or after 50 hours; drain 1 cup or more of fuel to remove water and sediment
Check Air Cleaner (clean if required)Check100 hrMonthly; clean if required; perform more often in extremely dusty conditions.
Clean Generator AssemblyClean100 hrMonthly
Radiator hoses for wear and cracksInspect100 hrMonthly or after 100 hours
Starting batteriesCheck100 hrMonthly or after 100 hours
Battery electrolyte levelCheck200 hrCheck at least every 200 hours of operation
Anti-freeze and DCA ConcentrationCheck250 hr3 moRefer to engine operation and maintenance manual.
Crankcase oil and filterChange250 hr12 moRefer to Cummins Engine Operation and Maintenance Manual. Standby applications: change every 12 months or 250 hours, whichever comes first.
Drive Belt TensionCheck250 hr3 moVisually check belt for evidence of wear or slippage. Replace if hard or brittle. Refer to engine operation and maintenance manual.
Fuel FiltersChange250 hr3 moRefer to engine operation and maintenance manual.
Governor AdjustmentCheck250 hr3 mo

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceOverspeed switch magnet-to-fly arm air gap (minimum)0.005inches (0.13 mm)
GapMechanical overspeed switch air gap between magnet and fly arm (replace switch if less)0.005inches (0.13 mm)
OtherAVR DROOP preset at factoryfive percent droop at full load and zero power factor
OtherBattery electrolyte corrected specific gravity (fully charged)1.260electrolyte temperature corrected
OtherBattery electrolyte specific gravity, fully charged (corrected)1.260corrected to 80 °F (27 °C)
OtherBattery recharge threshold specific gravity1.215
OtherBattery specific gravity1.260at 77°F (25°C)
OtherBattery specific gravity temperature correctionfour gravity points (0.004) for every ten degrees above 80 F (27 C)
OtherBattery specific gravity, fully chargedapproximately 1.260at 80°F (27°C)
OtherCoolant level50mmbelow radiator cap opening
OtherCycle cranking (12-lamp control)3 cycles of 15 seconds
OtherECM fuse F1 (starter solenoid circuit)20amps
OtherECM fuse F2 (fuel solenoid circuit)20amps
OtherECM fuse F3 (continuous B+ to remote circuits)15amps
OtherECM fuse F4 (ECM circuits)5amps
OtherECM fuse F5 (engine gauge circuits)5amps
OtherGovernor droop adjustment rangewithin 5percent of nominal frequency (3 Hz for 60Hz sets, 2.5 Hz for 50Hz sets)
OtherLow oil pressure / high engine temperature fault time delayabout 10secondsfollowing starter disconnect and inhibited during cranking
OtherOvercrank limit (Sentinel)60seconds
OtherOvercrank option limit (Detector)75seconds
OtherOvercrank time limit75seconds
OtherOverspeed warning range 60 Hz sets2000 to 2200RPM
OtherRandom voltage variation±1%for constant loads
OtherResponse jumper setting - 90 to 550 kWB to C
OtherResponse jumper setting - over 550 kWA to B
OtherResponse jumper setting - under 90 kWA to C
OtherStandard cycle cranking (Detector)three 15-second cranking cycles with two 15-second rest periods
OtherStarter disconnect speed450 to 570RPM
OtherTrailer brake shoe adjustment back-off10clicks
OtherTrailer surge brake actuator stroke length (service brakes if exceeds)1inch (25 mm)
OtherUnder-frequency roll-off (UFRO) threshold, 50 Hz applications49Hz
OtherUnder-frequency roll-off (UFRO) threshold, 60 Hz applications59Hz
OtherVoltage regulation±2%from no load to full load
PressureEngine oil pressure (normal)30 to 65psi (207 to 449 kPa)at normal operating temperature
PressureEngine oil pressure range (low oil pressure troubleshooting)25 to 65psi (172 to 449 kPa)
PressureIdle Oil Pressure10-30psiidle
PressureIdle Oil Pressure Shutdown Limit8psiidle
PressureIdle Oil Pressure Warning Limit12psiidle
PressureIdle oil pressure69-207kPaidle
PressureIdle oil pressure shutdown limit55kPaidle
PressureIdle oil pressure warning limit83kPaidle
PressureLow Oil Pressure shutdown threshold14psi (97 kPa)
PressureLow Oil Pressure shutdown threshold (less than)14psi
PressureLow oil pressure cutout switch test threshold (service lubricating system if less)10psiwhile cranking
PressureLow oil pressure shutdown14psi
PressureLow oil pressure shutdown97kPA
PressureLow oil pressure shutdown limit14psi (97 kPa)
PressureMax. Allowable Exhaust Back Pressure41in. H2O
PressureMax. Fuel Inlet Restriction4in. Hg (13.5 kPa)
PressureMax. Fuel Return Restriction10in. Hg (33.8 kPa)
PressureMax. Fuel Return Restriction20in. Hg (67.6 kPa)
PressureNormal Oil Pressure40-70psinormal
PressureNormal oil pressure276-483kPa
PressureNormal oil pressure range172 to 275kPa
PressureNormal oil pressure range25 to 40psi
PressureOil Pressure Shutdown Limit15psinormal
PressureOil Pressure Warning Limit20psinormal
PressureOil pressure shutdown limit103kPa
PressureOil pressure warning limit138kPa
PressurePre Low Oil Pressure warning threshold (less than)20psi

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantRefer to Cummins engine Operation and Maintenance Manual for coolant recommendations/specificationsBalanced coolant mixture of water, antifreeze and coolant additives.
Coolant50/50 mix of water and antifreezeBalanced coolant mixture of water, antifreeze and coolant additivesDrain and replace the mixture every 6 months or after 500 hours of operation. Do not add cold coolant to a hot engine; allow engine to cool below 120 F (50 C) before adding coolant.
Engine oilRefer to Cummins engine Operation and Maintenance Manual for lubricating oil classificationGensets are shipped with oil added.
Engine oilSAE 5W syntheticAPI CC/CD; sulphated ash max 1.85%; pour point 9°F (5°C) below lowest expected temperature; viscosity max 10,000 mPa·s at -31°F (-35°C) and min 4.1 mm²/s at 212°F (100°C)below -23°CFor ambient consistently below -10°F (-23°C) and no engine warm-up provision
Engine oil10W-30API CC/CD-23°C to -10°CFor ambient -10°F (-23°C) to 14°F (-10°C)
Engine oil15W-40API CC/CDabove -10°CFor ambient 14°F (-10°C) and above
Engine oil20W-40API CC/CDabove 0°CFor ambient 32°F (0°C) and above
FuelDieselDo not use zinc coated or copper fuel lines with diesel fuel.
FuelNo. 2 dieselEngine primarily designed for No. 2 diesel; No. 1 fuel or similar acceptable if meets specifications
FueldieselDo not use zinc coated or copper fuel lines with diesel fuel.
Hydraulic oilDOT-3Trailer master cylinder reservoir - keep at least half full

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

80
CodeNameMeaningSeverityAction
1122Rated/Idle TransInfo
1123Shutdown After Battle ShortA shutdown fault occurred while Battle Short was enabled and transitioned from enabled to disabled.ShutdownReview Fault History and perform corrective action.
1124Delayed ShutdownA shutdown fault became active while the Delayed Shutdown feature was enabled.WarningReview Fault History and perform corrective action.
1131Battle Sh ActiveControl is in Battle Short mode (bypasses several critical fault shutdowns).WarningNone; used for genset operation during emergencies.
121Speed Signal LostMag pickup speed indication is not being sensed.ShutdownRestart and check RPM on digital display; inspect MPU wires/connector pins; check for 3.5 to 15 VAC at MPU while cranking.
1311Customer Input #1WarningOptional customer selection (e.g., Low Fuel Day Tank, Water In Fuel, Ground Fault, Low Starting Hydraulic Pressure, Low Starting Air Pressure). Programmable: enable/disable, status/warning/shutdown, active closed or open, and display name.
1311, 1312, 1317, 1318CUSTOMER INPUT #1 - #4Optional customer-selected fault input is active.Disconnect signal lead from TB1 and reset the control; check external wiring/active input selection.
1312Customer Input #2WarningOptional customer selection; programmable (enable/disable, status/warning/shutdown, active open/closed, display name). Default #2 thru #4 - Warning.
1317Customer Input #3WarningOptional customer selection; programmable (default #3 - Low Fuel).
1318Customer Input #4WarningOptional customer selection; programmable (default #4 - Rupture Basin Fault).
1334Crit Scaler Out Of RangeIncorrect feature or calibration was entered into control.ShutdownReload correct feature/calibration file.
1335Noncrit Scaler Out Of RangeIncorrect feature or calibration was entered into control.WarningReload correct feature/calibration file.
1337No MessageInfo
135Oil Pressure Sensor HEngine oil pressure sender signal is shorted high.WarningCheck sender/connectors/wires; verify fault simulation not enabled; check 0.5 to 4.5 VDC at P7-13 (OP OUT) and P7-17 (OP COM).
141Oil Pressure Sensor LEngine oil pressure sender signal is shorted low.WarningCheck sender/connectors/wires; check for shorts/open circuits at P7-13, 17, 21.
1416Fail To ShutdownGenset continues to run after receiving shutdown command (Battle Short feature enabled).WarningCheck Battle Short feature setting.
1417Powr Down ErrorController cannot power down because of an unknown condition.WarningIndicates controller cannot power down because of unknown condition. Possible drain on battery. Contact an authorized service center for service.
143Pre-Low Oil PresEngine oil pressure dropped to an unacceptable level.WarningIndicates engine oil pressure has dropped below the warning trip point. If generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow code 415 procedure.
1433Emergency StopLocal Emergency Stop.ShutdownPull the button out; move switch to O; press Fault Acknowledge/Reset; select Manual or Auto.
1434Remote E-StopRemote Emergency Stop.ShutdownSee code 1433 to reset.
1435Low Coolant TempEngine coolant heater is not operating or not circulating coolant (coolant <=70 F [21 C]).WarningIndicates engine coolant heater is not operating or is not circulating coolant. Check coolant heater power supply for blown fuse or disconnected cord; check for low coolant level and replenish; look for coolant leaks and repair.
1438Fail To CrankEngine failed to crank after the PCC received a start signal.ShutdownTest for B+ at the starter; check fuse F3 (2 Amps); check K4 start pilot relay and starter circuitry; refer to code 121.
144Coolant Sensor HighEngine coolant temperature signal is shorted high.WarningCheck sender/connectors/wires; check resistance between P7-30 (IH20) and P7-34 (IH20 COM).
1442Weak BatteryDuring cranking battery voltage at or below weak battery trip point.WarningRecharge or replace battery; check electrolyte level and connections; check harness.
1443Battery FailedDead battery - engine will not start.ShutdownSee code 1438 instructions.
1444KW OverloadGenerator output power exceeded 105% of genset rating (3 sec at 110% of rated).WarningCheck load and load lead connections; check CTs and CT connections.
1445Short CircuitGenerator output current exceeded 175% of rated.ShutdownCheck load and load lead connections (fault may not reset for several minutes).
1446High AC VoltagePhase voltage exceeded 130% of nominal, or 110% of nominal for 10 seconds.ShutdownCheck fault simulation; clear fault and restart; refer to Generator/Base Board Isolation Procedure.
1447Low AC VoltagePhase voltage dropped below 85% of nominal for 10 seconds.ShutdownCheck load; reconnect per reconnection diagram; check PMG/field wiring; check P8-21/P8-22 shunt connections.
1448Under FrequencyEngine speed dropped below 90% of nominal for 10 seconds.ShutdownCheck fuel supply, intake air supply and load; check P8 connections.
1449Over FrequencyFrequency is 10% above base frequency for 20 seconds.WarningCheck fuel or air delivery problem; repair P7/P8 connections.
145Coolant Sensor LowEngine coolant temperature signal is shorted low.WarningCheck sender/connectors/wires; check for shorts at P7-30 and P7-34.
1452Gen CB Not CloseGenset circuit breaker (S2) failed to close when PTC enabled.WarningRefer to Section 5.
1453Gen CB Not OpenGenset circuit breaker (S2) failed to open when PTC enabled.WarningRefer to Section 5.
1459Reverse PowerImproper CT phasing.ShutdownCheck wiring to voltage sense circuit; refer to CT Installation in Section 6.
146Pre-High Coolant TempEngine has begun to overheat (coolant temperature risen to an unacceptable level).WarningReduce load; check air inlets/outlets and remove obstructions to airflow; if engine can be stopped follow code 151.
1461Loss Of FieldLoss of field (electric) due to reverse kVAR.ShutdownCheck field circuit.
1466Modem FailureControl cannot communicate with the modem.WarningCheck for open, short circuit to ground, and loose connections to the modem.
1468Network ErrorMomentary loss of communication from the LonWorks Network.WarningRefer to the LonWorks Network publications.
1469Speed/Hz MatchMeasured speed and measured AC output frequency do not agree.ShutdownCheck calibration file.
1471Over CurrentGenerator output current exceeded 110% of rated for 60 seconds.WarningCheck load and load lead connections.
1472Over CurrentGenerator output current exceeded 110% of rated; time/current calculation initiated shutdown.ShutdownCheck load and load lead connections (fault may not reset for several minutes).
151High Coolant TempEngine has overheated (coolant temperature above the shutdown trip point).ShutdownEngine has overheated. Allow engine to cool completely, then: check coolant level and replenish and repair leaks; check for obstructions to cooling airflow; check fan belt and repair or tighten; check blower fan and circulation pumps on remote radiator installations; reset control and restart.
197Low Coolant LevelEngine coolant level has fallen below the warning trip point.WarningIndicates engine coolant level has fallen below warning trip point. If generator is powering critical loads and cannot be shut down, wait until next shutdown period, then follow code 235 procedure. If engine can be stopped, follow code 235 procedure.
212Oil Temp Sensor HEngine oil temperature signal is shorted high.WarningCheck sender/connectors/wires; check resistance between P7-22 (OIL TEMP) and P7-26 (OIL TEMP COM).
213Oil Temp Sensor LEngine oil temperature signal is shorted low.WarningCheck sender/connectors/wires; check shorts and resistance between P7-22 and P7-26.
2327PTC FaultPTC module or communication link not working properly when PTC enabled.WarningCheck blinking light on PTC module; check B+ TB3-3 to TB3-4; check PTC status voltage TB3-5 to TB3-6 (~0.2 VDC); repower control.
2329Low S1 FrequencyLow utility (S1) frequency.WarningCheck S1 AC inputs and wiring to PTC at TB5; check sensor set points.
2331Low S1 VoltageLow utility (S1) voltage.WarningRepower PCC 2100 control to clear; check S1 AC inputs at TB5; check S1 pickup/dropout set points.
2335Excitation FaultLoss of all three voltage sense leads or failure in excitation circuit.ShutdownCheck field wiring (X1 and X2) for shorts or opens.
2336Memory ErrorControl memory error; data corruption of critical operating parameters.ShutdownTry reloading calibration file.
2337Pwr Tran DisabledPTC module available but PTC feature not enabled.WarningUse InPower to enable PTC feature; cycle power off for 5 seconds then repower.
2338Pwr Tran FailurePTC module trim enabled but control could not communicate with PTC module.WarningCheck blinking light and B+ TB3-3 to TB3-4; check connections between TB2 and TB3; cycle power.
2339Pwr Down EnabledPower Down (sleep) function enabled but PTC module or network board is active.WarningNone required.
234OverspeedEngine has exceeded normal operating speed.ShutdownClear fault and restart genset; check fault threshold; monitor RPM; check electronic governor actuator.
2341High Control TempControl temperature above normal (158 F [70 C]) for time greater than set time.WarningCheck genset room air flow.
2342Too Long In Idle (10 min.)Genset has been in Idle mode too long.WarningIndicates genset has been in Idle mode too long (10 minutes maximum).
235Low Coolant LevelEngine coolant level has fallen below the shutdown trip point.ShutdownCoolant level has fallen below the shutdown trip point. Allow engine to cool completely, then check coolant level and replenish, look for possible coolant leakage points and repair; reset control and restart.
2358High S1 VoltageUtility (S1) voltage increased above over voltage threshold.WarningMeasure S1 AC inputs at PTC module; check utility nominal voltage; check sensor set points.
2396S1 CB Not CloseUtility contact (S1) failed to close with PTC enabled.WarningRefer to Section 5.
2397S1 CB Not OpenUtility contact (S1) failed to open with PTC enabled.WarningRefer to Section 5.
2966PTC TimeoutPTC module is not responding; no longer communicating (PTC status may be okay).WarningCheck PTC status light; check cable connections between PTC module and control; cycle power.
2967Governor FaultGovernor hardware drive circuitry contains a fault condition.WarningCheck governor hardware drive circuitry.
2968AVR FaultAVR hardware contains a fault condition.WarningCheck AVR hardware.
2969LON FailureNo communications with LonWorks board.WarningCheck communications with LonWorks board.
2971No message (PTC Test Mode Active).InfoNone required; fault code only displayed in InPower.
2972Field OverloadAVR Field has been at Max Field for a time greater than the allowed Max Field Time.ShutdownCheck field load.
359Fail To StartEngine cranks but fails to start (possible fuel system problem).ShutdownPossible fuel system problem (engine cranks but fails to start). Check for empty fuel tank, fuel leaks, or plugged fuel lines; check for dirty fuel filter and replace if necessary; check for dirty or plugged air filter and replace if necessary; reset the control and restart.
415Low Oil PressureEngine oil pressure has dropped below the shutdown trip point.ShutdownIndicates engine oil pressure has dropped below shutdown trip point. Check oil level. If oil level is low, replenish. Reset control and restart.
421Oil TempEngine has begun to overheat (oil temperature above unacceptable level) (Optional).WarningReduce load; check air inlets/outlets; if engine can be stopped follow code 151 and check engine oil level.
441Low Bat VoltageBattery voltage supply to the control approaching a low level.WarningIndicates battery voltage supply to control is approaching a low level. Check battery charger fuse. Recharge or replace battery. Clean battery cable terminals and tighten all connections. Check battery charge voltage float level if applicable.
442High Bat VoltageBattery voltage supply approaching a high level at which control damage can occur.WarningIndicates battery voltage supply to control is approaching a high level. Check float level on battery charger if applicable (lower float level).
BASINDay tank BASIN lampFuel has overflowed into the rupture basin, indicating possible failure of pump-off and hi-fuel float switches or a leak in the day tankWarningRESET the control after fuel in the basin is safely disposed of and cause of overflow corrected
BLANKBlank lampFor customer use
F1ECM fuse F1Starter solenoid circuit, 20 ampsReplace with a fuse of the same type and amp rating
F2ECM fuse F2Fuel solenoid (switched B+) circuits, 20 ampsReplace with a fuse of the same type and amp rating
F3ECM fuse F3Continuous B+ out to remote circuits, 15 ampsReplace with a fuse of the same type and amp rating
F4ECM fuse F4ECM circuits, 5 ampsReplace with a fuse of the same type and amp rating
F5ECM fuse F5Engine gauge circuits, 5 ampsReplace with a fuse of the same type and amp rating
Fault 1 (Red)Fault 1 (Detector-12)Engine shut down because of a system fault; part of a 10 second time delay shutdown circuit (customer connections)ShutdownService as required; selection jumpers may choose warning only or non-timed shutdown

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjusting Values/Parameters adjustment

⚠ If Home button or Previous Main Menu button is pressed before pressing save symbol, changes are not saved.

  1. Press button next to symbol in display until + and − symbols are displayed.
  2. Press button next to arrow symbols to move to numeric character to change.
  3. Press button next to + symbol to increase value or select parameter.
  4. Press button next to − symbol to decrease value or select parameter.
  5. After adjusting values/selecting parameters, press symbol to save changes.
Dip Adjustment adjustment
  1. Turn the DIP pot clockwise to increase the voltage vs frequency slope for frequencies below the UFRO threshold.
  2. Greater slope gives greater voltage roll off as frequency drops, easing large load pickup but increasing voltage dip.
  3. Turn the pot fully counterclockwise to make the slope the same above and below the threshold frequency.
Dwell Adjustment adjustment
  1. Turn the DWELL pot clockwise to increase dwell time (voltage recovery time when frequency dips below threshold).
  2. Turn the DWELL pot fully counterclockwise to eliminate dwell.
  3. With no dwell, voltage recovery follows engine speed recovery.
Fuel Pump Control: Convert 120 VAC to 240 VAC adjustment
  1. Remove jumpers between TB1-5/TB1-6 and TB1-7/TB1-8; connect two jumpers between TB1-6 and TB1-7.
  2. Move selector switch S103 on control PCB to down position for 240 VAC.
  3. If equipped with a transformer, remove jumpers between H1/H3 and H2/H4 and connect two jumpers between H2 and H3.
  4. Attach a tag to the control box indicating the supply voltage.
Fuel Pump Control: Convert 240 VAC to 120 VAC adjustment
  1. Remove jumpers between TB1-6/TB1-7; connect one jumper TB1-5 to TB1-6 and one TB1-7 to TB1-8.
  2. Move selector switch S103 on control PCB to up position for 120V.
  3. If equipped with a transformer, remove jumpers between H2/H3 and connect one between H1-H3 and one between H2-H4.
Governor Adjustments (Type A Electric Governor) adjustment
  1. Set selector switch S1 to OFF, S2 to appropriate model position.
  2. Set pots initially: Gain 20%, I 20%, D 30%, Droop 0%.
  3. Start set, adjust Speed pot for required frequency (60Hz=1800RPM or 50Hz=1500RPM) at operating temperature.
  4. Disconnect load, turn Gain pot to 100% or until unstable, then back off until stable.
  5. Adjust D and I pots similarly; readjust Speed if necessary.
  6. Push throttle to minimum speed, release and observe overshoot (2-5 Hz acceptable); adjust I pot to reduce overshoot or hunting.
Over / Under Voltage Module Recalibration adjustment
  1. Remove the two screws securing the top to the case and withdraw the top assembly.
  2. Adjust the UNDER setpoint SET pot to 75 percent.
  3. Apply single-phase, 60 Hertz, 104.25 VAC across terminals L and N.
  4. Adjust pot R25 on the PC board until the relay trips (de-energizes).
  5. Adjust the OVER setpoint SET pot to 125 percent.
  6. Apply single-phase, 60 Hertz, 173.75 VAC across terminals L and N.
  7. Adjust pot R26 on the PC board until the relay trips (energizes).
  8. Repeat until no adjustments are necessary, then reassemble the module.
UFRO (Under Frequency Roll Off) Adjustment adjustment

⚠ High voltage - use insulating protection

  1. Note the red LED on the board lights when frequency dips below threshold.
  2. Turn the UFRO pot clockwise to raise the threshold frequency.
  3. Turn the UFRO pot counterclockwise to lower the threshold frequency.
  4. Determine threshold frequency by lowering generator frequency until the LED lights.
Voltage and Voltage Stability Adjustments (AVR) adjustment

⚠ High voltage - use dry wooden platform or rubber insulating mat, dry clothing, no jewelry, elbow length insulating gloves

  1. Measure generator output voltage while running without load at nominal frequency.
  2. Lock the control panel voltage trimmer at its midpoint if it cannot provide enough adjustment.
  3. Turn the VOLTS pot fully counterclockwise and the STABILITY pot to its midpoint.
  4. If the red LED lights, refer to Jumper Reconnections and UFRO Adjustments.
  5. Turn the VOLTS pot clockwise until rated voltage is obtained.
  6. If voltage becomes unstable under large load, turn the STABILITY pot clockwise until stable.
  7. Check and readjust the VOLTS pot each time the STABILITY pot is readjusted.
Generator/Base Board Isolation Procedure diagnostic

⚠ This test involves unregulated excitation; disconnect all loads.

⚠ HAZARDOUS VOLTAGE.

Tools: Voltmeter, 12 volt battery, Jumpers

  1. Throw line circuit breaker OFF and shut down the set.
  2. Remove control housing side cover; disconnect exciter stator X and XX leads from AC harness.
  3. Prepare to measure output voltage across generator terminals while set runs.
  4. Connect a 12V battery jumper positive (+) to X lead (Field +).
  5. Check polarity again; polarity must be correct.
  6. Start the set and connect battery negative (-) jumper to XX lead.
  7. If rated output voltage or higher and all phases balanced, generator is likely OK.
  8. If unbalanced troubleshoot main stator; if uniformly low troubleshoot exciter and field circuits.
Servicing the PMG diagnostic

⚠ Touching uninsulated high voltage parts can result in severe personal injury or death.

Tools: Wheatstone bridge, digital ohmmeter

  1. Disconnect leads P2, P3, P4 from voltage regulator.
  2. Start engine and let speed stabilize.
  3. Measure voltage across lead pairs P2-P3, P3-P4, P4-P2; should be at least 150 VAC (50Hz) or 180 VAC (60Hz).
  4. Stop set and measure resistance across same lead pairs; each winding approximately 4.4 ohms.
  5. Torque PMG rotor center bolt to 40 ft-lbs (54 Nm) when reassembling; stator leads must be at 12 o'clock.
Testing Diodes (Rotating Rectifier Assembly) diagnostic

⚠ Brush dust off regularly; layers of dust can cause diodes to overheat and fail

Tools: Ohmmeter

  1. Disconnect the diode pigtails from the terminal posts.
  2. Using an ohmmeter, measure resistance between each diode pigtail and the plate on which it is mounted.
  3. Reverse the meter test probes and repeat the tests.
  4. Resistance should be high in one direction and low in the other.
  5. If resistance is high or low in both directions, replace the diode.
  6. Torque diodes to 36 to 42 in-lbs (4 to 4.8 Nm) and pigtail terminals to 24 in-lbs (2.7 Nm).

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
AVR response jumperA to CFor generator output 90 kW or less (SX440 and MX321)
Auxiliary terminal board TB21K1, K2, P2, P3, P4, S2, S1, A2, A1A1 and A2 connect a VAR/power factor controller when paralleling with a utility; S1 and S2 connect a droop compensating CT when paralleling with a generator set or utility
CT1 - U load leads (A phase); CT2 - V load leads (B phase); CT3 - W load leads (C phase)6 lead gensets: generator output leads routed through CTs; 12 lead gensets: load wires routed through CTs12-lead sets have dual secondary CTs (3 pins); 6-lead sets have single secondary CTs (2 pins)
Day tank LO SHUTDOWN engine shutdown connectionTB1-14 to engine block ground; TB1-15 to TB2-16 on the ECM
Fault relay K8/K9 (Dry Contact Module)K8=Over Crank, Low Oil Pressure, High Engine Temperature, Low Coolant Level, Low Fuel Level; K9=Low Fuel Level, Rupture BasinContact ratings: 40A max carry/break N.O. 12V coil, 30A N.C. 12V coil, 20A N.O./10A N.C. 24V coil
MX321 PMG-excited jumper positions2-3, 4-5 and 6-7These jumpers must be in these positions
MX321 voltage regulator frequency jumper3-2 for 50 Hz; 3-1 for 60 Hz
SX440 voltage regulator frequency jumperC-50 for 50 Hz; C-60 for 60 Hz
TB3 (ECM alternative RUN/STOP/REMOTE connection)TB3-1=REMOTE, TB3-2=RUN, TB3-3=STOPProvides alternative direct connection to ECM for troubleshooting or customer connection
Voltage trimmer R21voltage regulator terminals 1 and 2There must be a jumper between terminals 1 and 2 when voltage trimmer R21 is not used
single phaseQSG-Series power distribution panel voltage selector switch S1 positionmain output terminalsRotary switch under lockable cover selects 120/240 VAC single phase
single phaseVoltage regulator terminal 6jumpered to terminal 8When the generator is connected for single-phase output, terminal 6 is not connected to the isolation transformer
three phaseQSG-Series power distribution panel voltage selector switch S1 positionmain output terminalsRotary switch selects 120/208 VAC three phase
110V - 120V L-NSingle phase, 2-wireJumper locations for single phase, 2-wirePTC Module AC wiring (0300-5382-01, -02)
120single phaseDay tank fuel pump control power reconnectionmove jumpers from TB1-6/TB1-7 to TB1-5/TB1-6 and TB1-7/TB1-8Move selector switch S103 on the control PCB to the up position for 120 V (factory set for 240 V, S103 down)
190, 200, 208, 220, 230, 240, 380, 416, 440, 460, 600 (L-L)3 (three phase)3 or 4 wiresVoltage Configuration submenu; default = 3Ph 208V 4W
190V - 240V L-LThree phaseJumper locations for three phase, 190V-240V L-LUse 0300-5382-01 for 190V-240V L-L, 50/60 Hz
200, 220, 230, 240 (L-L)1 (single phase)3 wiresVoltage Configuration submenu (Governor/Regulator Setup)
200V - 240V L-LSingle phase, 3-wireJumper locations for single phase, 3-wirePTC Module AC wiring
24Day tank fuel pump control logic power (two lead harness, no transformer)TB1-19 to positive (+) 24 V starter motor solenoid; TB-20 to negative (-)Provides 24 VDC for the control circuit
240single phaseDay tank fuel pump control default factory connectionjumpers between terminals TB1-6 and TB1-7Selector switch S103 on the control PCB in the down position for 240 V
380V - 600V L-LThree phaseJumper locations for three phase, 380V-600V L-LUse 0300-5382-02 for 380V-600V L-L, 50/60 Hz

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What is the power rating of the Cummins/Onan DGFB?

The Cummins/Onan DGFB is rated 175 kW standby (219.0 kVA).

What engine does the Cummins/Onan DGFB use?

The Cummins/Onan DGFB is powered by the Cummins/Onan 6CTA8.3 engine.

Is the Cummins/Onan DGFB diesel or gas?

The Cummins/Onan DGFB runs on Diesel.

What is the oil capacity of the Cummins/Onan DGFB?

The Cummins/Onan 6CTA8.3 engine in the Cummins/Onan DGFB has an oil capacity of 19.0 liters.

What is the coolant capacity of the Cummins/Onan DGFB?

The Cummins/Onan DGFB cooling system holds 28 liters (7.4 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the continuous rating of the Cummins/Onan DGFB?

The Cummins/Onan DGFB is rated 160 kW prime (200 kVA), against 175 kW standby.

What size fuel tank does the Cummins/Onan DGFB have?

The Cummins/Onan DGFB has a 24.8 liter (7 US gallon) fuel tank.

What voltages is the Cummins/Onan DGFB available in?

The Cummins/Onan DGFB is offered in 110/190 V, 120/208 V, 220/380 V, 240/416 V, 139/240 V, 277/480 V, 3-phase.

What battery does the Cummins/Onan DGFB use?

The Cummins/Onan DGFB uses 1 battery, 12 Volts DC V each, 1080 CCA, group 4D, per the manufacturer specification sheet.

What oil filter does the Cummins/Onan DGFB use?

The Cummins/Onan DGFB uses oil filter part number LS1174s.

What fuel filter does the Cummins/Onan DGFB use?

The Cummins/Onan DGFB uses fuel filter part number 3843760.

What air filter fits the Cummins/Onan DGFB?

The Cummins/Onan DGFB uses air filter part number AF4669.

Troubleshooting

6

Symptoms & remedies

SymptomRemedy
Generator does not startCheck the fault codes and refer to the troubleshooting table for specific issues. Ensure that all connections are secure, and the control panel is powered on.
Generator produces low voltage outputRefer to the fault codes and troubleshooting table for possible causes such as a faulty alternator or incorrect settings. Check the generator's load and ensure it is within the rated capacity.
Generator produces high voltage outputRefer to the fault codes and troubleshooting table for possible causes such as a faulty alternator or incorrect settings. Check the generator's load and ensure it is within the rated capacity.
Generator produces inconsistent voltage outputRefer to the fault codes and troubleshooting table for possible causes such as a faulty alternator or incorrect settings. Check the generator's load and ensure it is within the rated capacity.
Generator produces inconsistent frequency outputRefer to the fault codes and troubleshooting table for possible causes such as a faulty alternator or incorrect settings. Check the generator's load and ensure it is within the rated capacity.
Generator produces noise during operationRefer to the fault codes and troubleshooting table for possible causes such as a faulty alternator or incorrect settings. Check the generator's load and ensure it is within the rated capacity.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Cummins/Onan DGFB troubleshooting guide (87 entries) →

Parts

250
Part #DescriptionQtySystem
102-1147Gasket, Drain-Oil Pan1Gasket Amazon eBay
102-1356Gasket, Oil Drain1Gasket Amazon eBay
106334Hose, Plain1Hose Amazon eBay
122-0756Element - Oil Filter1Oil filter Amazon eBay
130-3216V-belt1Belt Amazon eBay FridayParts $17.99
130-3536Filter, Water - Service1Coolant filter Amazon eBay
130-3539Filter, Water - Pre-Charging1Coolant filter Amazon eBay
140-2241Element, Air Cleaner1Air filter Amazon eBay $299.95 NAPA $87.00
140-2251Element, Air Cleaner Secondary (Inner)1Air filter Amazon eBay
140-2252Element, Air Cleaner - Secondary (Inner)1Air filter Amazon eBay
145530Seal, O Ring1Seal Amazon eBay
149-2250Filter, Fuel - Primary1Fuel filter Amazon eBay
149-2251Filter, Fuel - Secondary1Fuel filter Amazon eBay $19.95
150-0956COVER, FLYWHEEL GUARD1Sensor Amazon eBay
150-2201Sensor, Speed – Magnetic1Sensor Amazon eBay
155-3150-04Muffler, Critical1Muffler Amazon eBay
155-3164-01Pipe, Exhaust1Pipe Amazon eBay
193-0244Sender, Pressure - 0i11Sensor Amazon eBay
193-0322Sender, Coolant-Low1Sensor Amazon eBay
193-0353Sender, Temperature - Oil1Sensor Amazon eBay
193-0375# Sender, Water Temperature1Sensor Amazon eBay
210753Clamp, Hose4Hose Amazon eBay
3016627Alternator1Alternator Amazon eBay FridayParts $175.24
3016628Alternator1Alternator Amazon eBay
3025152Hose, Plain1Hose Amazon eBay $74.95
309-0128Thermostat - Adjustable1Thermostat Amazon eBay
309-0269Sender, Temperature-Lo Engine1Sensor Amazon eBay $239.00
309-0272Regulator, Voltage - 24 VDC (Used on 35 A MP Alternator)1Alternator Amazon eBay
309-0555Switch, Thermostatic1Sensor Amazon eBay
309-0561Alternator & Drive Components Group Pulley. Alternator - Multi Groove (Use with 35 A MP Alternator)1Alternator Amazon eBay
319-2653Window, Control (If Equipped)1Window Amazon eBay
3283227Coupling, Plain Hose1Hose Amazon eBay
3318853Combination Full-Flow/Bypass Lubricating Oil Filter1Oil filter Amazon eBay $74.95 NAPA $66.59
3377363Lube Oil, Cummins Premium Blue 15W40 (one-gallon jugs)6 Gal.Fluid Amazon eBay
3519762Gasket, Turbocharger1Gasket Amazon eBay
3802975Pump, Water1Pump Amazon eBay FridayParts $143.99
3819725Clamp, Hose2Seal Amazon eBay KuduParts $10.00
3833680Bracket, Air Cleaner2Air filter Amazon eBay $74.95
3837348Cleaner, Air1Air filter Amazon eBay $659.95
3843760Fuel Filter (Fleetguard FS1251 equivalent)1Fuel filter Amazon eBay $74.95
3897933Bracket, Belt Guard1Belt Amazon eBay
3897934Bracket, Belt Guard1Belt Amazon eBay
3897937Bracket, Belt Guard1Belt Amazon eBay
3902089Seal, O Ring1Seal Amazon eBay
3902466Seal, Rectangular Ring1Seal Amazon eBay
3903475Seal, Rectangular Ring1Seal Amazon eBay FridayParts $220.00
3905084Hose, Flexible1Hose Amazon eBay
3905449Seal, Rocker Lever Cover1Seal Amazon eBay
3907167Coupling, Plain Hose1Hose Amazon eBay
3907177Seal, Rectangular Ring (Cylinder-Block group BP97003)1Seal Amazon
3908139Front Seal Service Kit, includes installation tools (Front-Gear-Cover group BP9733-04)1Seal Amazon
3910824Seal, O Ring6Seal Amazon eBay FridayParts $11.91
3911560Belt, Drive - Alternator1Belt Amazon eBay FridayParts $43.37
3911562Belt1Belt Amazon eBay $26.05
3911571Belt, Drive - Fan & Altr (6CTA Engine)1Belt Amazon eBay $74.95 FridayParts $49.99
3911875Hose, Flexible1Hose Amazon eBay
3911880Coupling, Elbow Hose1Hose Amazon eBay
3912183Hose, Plain1Hose Amazon eBay
3913724Hose, Plain1Hose Amazon eBay
3913751Hose, Plain1Hose Amazon eBay
3913994Seal, O Ring (Front-Gear-Cover group BP9733-04)1Seal Amazon
3914303Gasket, Gear Housing (Front-Gear-Cover group BP9733-04)1Gasket Amazon
3914311Gasket, Int Manifold Cover1Gasket Amazon eBay
3916300Gasket, Turbocharger1Gasket Amazon eBay FridayParts $12.52
3916529Hose, Plain1Hose Amazon eBay
3917779Gasket, Gear Cover (Front-Gear-Cover group BP9733-04)1Gasket Amazon
3918163Clamp, Hose8Hose Amazon eBay
3918521Clamp, Hose1Hose Amazon eBay
3918607Hose, Elbow1Hose Amazon eBay
3918611Hose, Plain3Hose Amazon eBay
3918779Gasket, Connection1Gasket Amazon eBay
3919520Bracket, Air Cleaner1Air filter Amazon eBay $224.95
3920762Hose, Elbow1Hose Amazon eBay
3921402Motor, Starting1Starter Amazon eBay
3921403Starter 24V1Starter Amazon eBay FridayParts $484.88
3921633Guard, Belt1Belt Amazon eBay
3921691Gasket, Exh Out Connection1Gasket Amazon eBay
3922900Tensioner, Belt1Belt Amazon eBay FridayParts $39.70
3925025Hose, Molded1Hose Amazon eBay
3925697Bracket, Belt Tensioner1Belt Amazon eBay
3926534Housing, Thermostat1Thermostat Amazon eBay
3928639Thermostat2Thermostat Amazon eBay FridayParts $15.70
3929614Pump, Water1Pump Amazon eBay
3931350Gasket, Oil Drain1Gasket Amazon eBay $74.95
3931608Gasket, Acc Drive Cover1Gasket Amazon eBay $74.95 KuduParts $8.00
3931824Seal, O Ring1Seal Amazon eBay
3931970Hose, Plain1Hose Amazon eBay $82.45
405-5744Post, Housing - Center4Post Amazon eBay
405-5832Door, Housing6Door Amazon eBay
405-5908Panel, Side - Radiator Housing2Panel Amazon eBay
405-5916Post, Corner - Housing2Post Amazon eBay
405-5917Panel, End - Roof2Panel Amazon eBay
406-0831Hinge, Door14Hinge Amazon eBay
501-0441Line, Fuel - Flex (Fuel In)1Hose Amazon eBay
502-0047Nipple, Pipe (1/4)1Nipple Amazon eBay
503-0197Clip, Hose1Hose Amazon eBay $7.99
503-0365Clamp, Hose1Hose Amazon eBay
503-0446Clamp, Hose2Hose Amazon eBay
503-0465Clamp, Hose2Hose Amazon eBay $23.99
503-0685Clamp, Hose1Hose Amazon eBay $15.00
503-1195Hose (3/4"ID x 24"LG)1Hose Amazon eBay
503-1379-01Hose, Radiator2Hose Amazon eBay
503-1595Hose1Hose Amazon eBay
503-1599Hose, Radiator1Hose Amazon eBay
509-0266-02O-Ring1Seal Amazon
526-0451Washer, Flat - Stainless Steel (M8)2Washer Amazon eBay
AC9055-01Air Cleaner1Air filter Amazon eBay
AF4669Air Cleaner1Air filter Amazon eBay $225.00
B-45CHECKING BATTERYBattery Amazon SinoCMP $1269.00
FS1251Fuel Filter1Fuel filter Amazon eBay $119.92 NAPA $23.51
LF9009Lube Filter1Oil filter Amazon eBay $110.91 NAPA $70.33 FridayParts $125.00
LS1174sOIL FILTEROil filter Amazon eBay
RU5045Air Cleaner1Air filter Amazon eBay $26.95 NAPA $101.05
V70509Lube Oil4 Gal.Fluid Amazon eBay
WF2072Coolant Filter1Coolant filter Amazon eBay $20.95 NAPA $29.33
102-1237Adapter, Drain-Oil1Service part / kit Amazon eBay
102483End, Control Rod2Service part / kit Amazon eBay
108722Clip2Service part / kit Amazon eBay FridayParts $50.00
127007Screw, Pan Head Cap6Service part / kit Amazon eBay
130-3212Advanced Efficiency Hydraulic/Transmission Filter1Service part / kit Amazon eBay FridayParts $65.40
140-1260Fitting, Safety Filter2Service part / kit Amazon eBay $116.27 NAPA $10.13
140-1548Indicator, Service1Service part / kit Amazon eBay $49.99 NAPA $32.16
140-2240Cleaner, Air (Incl Element)1Service part / kit Amazon eBay
140332Clamp, T Bolt2Service part / kit Amazon eBay
146159Washer, Plain1Service part / kit Amazon eBay
146160Washer, Plain4Service part / kit Amazon eBay
155-2307Silencer1Service part / kit Amazon eBay
180371Clip2Service part / kit Amazon eBay
203555Connection, Exhaust Outlet1Service part / kit Amazon eBay FridayParts $293.27
204991Washer, Plain2Service part / kit Amazon eBay
213365Screw, Hexagon Head Cap8Service part / kit Amazon eBay
3007636Plug, Expansion1Service part / kit Amazon eBay
3008468Plug, Pipe 1/2 NPT1Service part / kit Amazon eBay $74.95
3010596Screw, Captive Washer Cap2Service part / kit Amazon eBay
3018006Screw, Hexagon Head Cap1Service part / kit Amazon eBay
3026910Cable1Service part / kit Amazon eBay
3028870Connection, Tur Oil Inlet1Service part / kit Amazon eBay
3030871Gauge, Pressure1Service part / kit Amazon eBay
3030872Gauge, Temperature1Service part / kit Amazon eBay
3031348Flange, Power Takeoff1Service part / kit Amazon eBay
3031643Rectifier1Service part / kit Amazon eBay
3032105Bearing, Ball2Service part / kit Amazon eBay KuduParts $16.00 FridayParts $17.99
3033379Control, Vernier1Service part / kit Amazon eBay
3033800Washer, Plain4Service part / kit Amazon eBay
3035083Isolator, Vibration2Service part / kit Amazon eBay
3035084Isolator, Vibration4Service part / kit Amazon eBay
3039554Switch, Push Button1Service part / kit Amazon eBay
3039570Ammeter1Service part / kit Amazon eBay
3049554Hourmeter & Tachometer1Service part / kit Amazon eBay
3050323Speed Switch, Electronic1Service part / kit Amazon eBay FridayParts $233.99
309-0553Switch, Temperature-Pre Water1Service part / kit Amazon eBay $127.46
309-0554SWITCH WATER1Service part / kit Amazon eBay $159.00
3175239Nut, Lock4Service part / kit Amazon eBay
3284244Connector, Female1Service part / kit Amazon eBay
332-1473Lug, Solderless1Service part / kit Amazon eBay
3393823Bolt, Carriage1Service part / kit Amazon eBay
3885910Red Paint, Spray can1Service part / kit Amazon eBay
3900629Screw, Hex Flange Head Cap2Service part / kit Amazon eBay
3900630Screw, Hex Flange Head Cap2Service part / kit Amazon eBay $74.95 FridayParts $41.99
3900631Screw, Hex Flange Head Cap2Service part / kit Amazon eBay
3900632Screw, Hex Flange Head Cap1Service part / kit Amazon eBay
3900633Screw, Hex Flange Head Cap1Service part / kit Amazon eBay
3901249Screw, Hex Flange Head Cap2Service part / kit Amazon eBay FridayParts $31.20
3901757Screw, Hex Flange Head Cap1Service part / kit Amazon eBay
3902115Screw, Hex Flange Head Cap M12 x 1.75 x 651Service part / kit Amazon eBay
3902468Cap, Filler1Service part / kit Amazon eBay KuduParts $9.00 FridayParts $11.76
3902662Nut, Hexagon Flange2Service part / kit Amazon eBay FridayParts $23.56
3903463Cover, Access Hole1Service part / kit Amazon eBay KuduParts $10.00 FridayParts $12.98
3903990Screw, Hex Flange Head Cap2Service part / kit Amazon eBay FridayParts $12.58
3904971Connection Water Transfer1Service part / kit Amazon eBay
3905156Shim A/R 1.00 mm Thick8Service part / kit Amazon eBay
3905157Shim A/R 1.04 mm Thick8Service part / kit Amazon eBay
3905158Shim A/R 1.08 mm Thick8Service part / kit Amazon eBay
3905159Shim A/R 1.10 mm Thick8Service part / kit Amazon eBay
3905160Shim A/R 1.14 mm Thick8Service part / kit Amazon eBay
3905161Shim A/R 1.18 mm Thick8Service part / kit Amazon eBay
3905162Shim A/R 1.20 mm Thick8Service part / kit Amazon eBay
3905163Shim A/R 1.24 mm Thick8Service part / kit Amazon eBay
3905164Shim A/R 1.28 mm Thick8Service part / kit Amazon eBay
3905165Shim A/R 1.30 mm Thick8Service part / kit Amazon eBay
3905166Shim A/R 1.34 mm Thick8Service part / kit Amazon eBay
3905167Shim A/R 1.38 mm Thick8Service part / kit Amazon eBay
3905168Shim A/R 1.40 mm Thick8Service part / kit Amazon eBay
3905169Shim A/R 1.44 mm Thick8Service part / kit Amazon eBay
3905170Shim A/R 1.48 mm Thick8Service part / kit Amazon eBay
3905171Shim A/R 1.50 mm Thick8Service part / kit Amazon eBay
3905172Shim A/R 1.54 mm Thick8Service part / kit Amazon eBay
3905173Shim A/R 1.58 mm Thick8Service part / kit Amazon eBay
3905174Shim A/R 1.60 mm Thick8Service part / kit Amazon eBay
3905175Shim A/R 1.64 mm Thick8Service part / kit Amazon eBay
3905176Shim A/R 1.68 mm Thick8Service part / kit Amazon eBay
3905177Shim A/R 1.70 mm Thick8Service part / kit Amazon eBay
3905178Shim A/R 1.74 mm Thick8Service part / kit Amazon eBay
3905180Shim A/R 1.78 mm Thick8Service part / kit Amazon eBay
3905181Shim A/R 1.80 mm Thick8Service part / kit Amazon eBay
3905182Shim A/R 1.84 mm Thick8Service part / kit Amazon eBay
3905183Shim A/R 1.88 mm Thick8Service part / kit Amazon eBay
3905184Shim A/R 1.90 mm Thick8Service part / kit Amazon eBay
3905185Shim A/R 1.94 mm Thick8Service part / kit Amazon eBay
3905186Shim A/R 1.98 mm Thick8Service part / kit Amazon eBay $74.95
3906436Tube, Water Inlet1Service part / kit Amazon eBay
3906439Plate, Clamping1Service part / kit Amazon eBay
3906619Plug, Pipe1Service part / kit Amazon eBay
3906715Screw, Hex Flange Head Cap2Service part / kit Amazon eBay
3906733Screw, Hex Flange Head Cap4Service part / kit Amazon eBay
3907978Stud M10 x 1.50(Both Ends) x 504Service part / kit Amazon eBay
3908402Tube, Water Outlet1Service part / kit Amazon eBay
3910901Screw, Hex Flange Head Cap1Service part / kit Amazon eBay
3911670Manifold, Exhaust1Service part / kit Amazon eBay
3912151Plate, Clamping2Service part / kit Amazon eBay
3912159Connection, Water Outlet1Service part / kit Amazon eBay
3914502Aftercooler1Service part / kit Amazon eBay
3914868Plate, Cover1Service part / kit Amazon eBay FridayParts $41.48
3915772Seal, Rectangular Ring (Front-Gear-Cover group BP9733-04)1Service part / kit Amazon
3916326Connection, Exhaust Outlet1Service part / kit Amazon eBay
3916518Screw, Hex Flange Head Cap M10 x 1.50 x 1258Service part / kit Amazon eBay FridayParts $42.10
3916585Screw, Hexagon Head Cap6Service part / kit Amazon eBay
3917394Connection, Water Transfer1Service part / kit Amazon eBay FridayParts $39.00
3918109Screw, Hex Flange Head Cap M8 x 1.25 x 2518Service part / kit Amazon eBay
3918192Washer, Sealing2Service part / kit Amazon eBay
3918498Screw, Hex Flange Head Cap M10 x 1.50 x 1454Service part / kit Amazon eBay
3918500Tube, Air1Service part / kit Amazon eBay
3918542Spacer, Mounting1Service part / kit Amazon eBay
3918927Connection Water Transfer1Service part / kit Amazon eBay
3919461Block, Terminal1Service part / kit Amazon eBay
3919462Harness, Wiring1Service part / kit Amazon eBay
3919465Cabinet, Instrument1Service part / kit Amazon eBay
3919467Decal1Service part / kit Amazon eBay
3919563Tube, Water Transfer1Service part / kit Amazon eBay
3919577Heater, Engine1Service part / kit Amazon eBay
3919578Panel, Instrument1Service part / kit Amazon eBay
3919585Panel, Eng Instrumentation1Service part / kit Amazon eBay
3919687Connector, Female1Service part / kit Amazon eBay FridayParts $13.58
3919748Dataplate1Service part / kit Amazon eBay
3919750Brace, Exh Out Connection1Service part / kit Amazon eBay $211.70
3919751Shield, Heat1Service part / kit Amazon eBay
3919814Connection, Tur Oil Drain1Service part / kit Amazon eBay
3919815Tube, Tur Oil Drain1Service part / kit Amazon eBay
3919871Bracket, Cable1Service part / kit Amazon eBay
3921533Shield, Dust1Service part / kit Amazon eBay FridayParts $15.99
3921724Tag, Identification1Service part / kit Amazon eBay
3923360Plate, Clamping3Service part / kit Amazon eBay
3924389Washer, Sealing1Service part / kit Amazon eBay
3924798Shaft, Idler1Service part / kit Amazon eBay
3925186Screw, Flat Head Cap2Service part / kit Amazon eBay
3925568Damper, Vibration1Service part / kit Amazon eBay FridayParts $145.99
3925749Connector, Banjo1Service part / kit Amazon eBay $229.95
3925883Screw, Hex Flange Head Cap1Service part / kit Amazon eBay
3926125Screw, Hexagon Head Cap3Service part / kit Amazon eBay
3926901Pulley, Idler1Service part / kit Amazon eBay KuduParts $50.00

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime25%13.03.4
Prime50%23.06.1
Prime75%33.08.8
Prime100%45.012.0
Standby25%14.03.7
Standby50%25.06.6
Standby75%36.09.6
Standby100%11.02.9

Available documents

Spec sheet — Cummins-DGFB-data-sheet (Cummins/Onan)Spec sheet — Cummins-DGFB-spec-sheet (Cummins/Onan)Operator's manual — 960-0107 Cummins DGBB DGCB DGDB DGFA Operator's Manual (7-2009) (Cummins/Onan)Operator's manual — 960-0144 Onan DGEA DGFA DGFB Operator's Manual (7-2009) (Cummins/Onan)Operator's manual — 960-0615C Cummins DGBB DGC DGFA Series Operator's Manual (10-2003) (Cummins/Onan)Operator's manual — Cummins-DGBB-DGBC-DGCA-DGCB-DGCG-DGFA-DGFB-DGFC-DGFS-operator-manual (Cummins/Onan)Parts manual — 0932-0112 Onan Post-Sale Literature Index (07-1998) (Cummins/Onan)Parts manual — 0960-0211 I8 201410 (Cummins/Onan)Parts manual — 0960-0233 (Cummins/Onan)Parts manual — 0960-0297 I9 202204 (Cummins/Onan)Parts manual — 960-0233 Onan DGEA DGFA DGFB CT61CTA Parts Manual (2-1993) (Cummins/Onan)Service manual — 960-0505 Onan DGxx QSxx Detector Controls Generator Set Service Manual (04-2001) (Cummins/Onan)Service manual — 960-0510B Onan DGBB thru DGFC Series Service Manual (10-1998) (Cummins/Onan)Service manual — 960-0518D Cummins DGBB DGC DGDA DGFB Series Service Manual (2-2004) (Cummins/Onan)Service manual — 960-0618D Cummins DGBB DGCA DGEA DGFA Series Installation Manual (10-2001) (Cummins/Onan)Service manual — 960-0628D Cummins DGB DGC DGF Series Installation Manual (2-2004) (Cummins/Onan)

This page was generated from the 16 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Air filter AF4669$225.00
Fuel filter 3843760$74.95
Belt 3911562$26.05
3 priced items$326.00