Manufacturer-documented fuel consumption for 16 175–180 kW Diesel generator sets — median 11.49 gal/h at full load, 6.74 gal/h at half load.
Compare 175–180 kW Diesel generator specs side-by-side →
| Model | kW | gal/h @ 50% | gal/h @ 100% | Tank (L) | Runtime @ 50% (h) |
|---|---|---|---|---|---|
| Caterpillar D175 | 175 | 7.93 | 12.63 | 12 | 0.4 |
| Caterpillar XQ175 | 175 | 8.72 | 13.05 | 988 | 29.9 |
| Cummins/Onan DGFB | 175 | — | 2.91 | 25 | — |
| Kohler 175EFOZCJ | 175 | 6.74 | 14.03 | — | — |
| Perkins 1106D-E66TAG4 | 175 | 6.87 | 12.94 | — | — |
| SDMO J175U | 175 | 6.21 | 12.42 | 340 | 14.5 |
| Seneca 1 75 DDS 3 | 175 | — | 13.08 | — | — |
| Baudouin E BD XX 0220 | 176 | 5.92 | 11.39 | 360 | 16.1 |
| Cummins/Onan C220 D5 | 176 | 3.96 | — | 150 | 10.0 |
| Doosan FDD 176 M | 176 | — | 8.90 | 1594 | — |
| FG Wilson P220HE | 176 | — | 11.39 | 350 | — |
| Generac MDG175 | 176 | 5.23 | 8.77 | 1355 | 68.4 |
| SDMO R220 | 176 | 5.81 | 11.49 | 71 | 3.2 |
| John Deere 6068HF 285 | 177 | — | 9.30 | 13 | — |
| Magnum MMG185 | 177 | 7.61 | 7.40 | 1295 | 45.0 |
| FG Wilson P220-1 | 178 | 6.79 | 11.89 | 418 | 16.3 |
Figures from each model’s own manufacturer documentation (spec sheets and manuals); runtime = documented tank capacity ÷ consumption at 50% load. Verify against the datasheet for your exact configuration.
Across 15 models with manufacturer data, full-load consumption runs 2.91–14.03 gal/h (median 11.49); at 50% load the median is 6.74 gal/h.
At 50% load, documented tank sizes give 0.4–68.4 hours (median 16.1 h) across 9 models.