Home›Cummins/Onan›Cummins/Onan DFBF

Cummins/Onan DFBF Generator Set

The Cummins/Onan DFBF is a 275 kW (344 kVA) diesel standby generator set powered by a Cummins/Onan NT855 engine. It operates at 60 Hz and 3-phase. It holds about 40 L (10.6 gal) of oil and 51 L (13.5 gal) of coolant. Starting uses 2 group-8 batteries rated 1400 CCA at 12 V. The set measures 3607×1270×1615 mm (142.0×50.0×63.6 in) and weighs about 3289 kg (7251 lb).

275 kW
Standby
8.55 L
Displacement
40.0 L
Oil capacity
4
Document types

How to read your Cummins/Onan serial & model number →

Typical fuel consumption for 275–280 kW Diesel generators →

Compare with other 275–280 kW Diesel generators →

Service parts for the DFBF

Grouped by system, with how many of each the parts manual calls for.

Air intake

1 required

Fuel system

1 required

Oil system

1 required

Belts

1 required

Cooling system

2 required
123460Coolantsee priceAmazon
B342-1Coolant filtersee priceAmazon

Electrical

1 required

Ignition

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

Fueldiesel
Frequency60.0 Hz
Standby power275 kW
Standby kVA344
Prime power250 kW
ControllerPowerCommand, PowerCommand 2100, PowerCommand 2100 (PCC), PowerCommand 3100
Oil capacity40.0 L
Phase3
Battery group8D
Battery cranking1400 CCA
Battery voltage12 V
Battery quantity2
Coolant capacity51 L
Dimensions (L×W×H)3607×1270×1615 mm
Dry weight3289 kg

Engine

Cummins/Onan NT855
Oil capacity40.0 L
Coolant capacity51.0 L
Displacement8.55 L
Aspirationturbocharged
Rated speed1800 rpm

Filters for the Cummins/Onan NT855

8

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

SystemFilterDescriptionCross-references
Oil filterP551670Lube Filter, Spin-On Full FlowCUMMINS 298670, CUMMINS 299670, NAPA 1970, CARBOCOL 0026 FridayParts $26.68
Oil filterP550777Lube Filter, Spin-On BypassCUMMINS 3021658, CUMMINS 33004232, NAPA 1749, BALDWIN B7577 FridayParts $43.56
Fuel filterP550105Fuel Filter, Spin-On PrimaryCUMMINS 154700, CUMMINS 154710, NAPA 3109, NAPA 3405 buy
Fuel filterP557440Fuel Filter, Spin-On SecondaryCUMMINS BM78672, BALDWIN BF970, LPM 00013505994, WALGAHN-MOTORENTECHN 00811464 FridayParts $189.69
Fuel / water separatorP550106Fuel Filter, Water Separator Spin-OnCUMMINS 154789, CUMMINS 156164, NAPA 3405, BALDWIN BF957-D FridayParts $285.60
Fuel / water separatorP558000Fuel Filter, Water Separator Spin-On Twist&DrainCUMMINS 3308638, CUMMINS 3308683, NAPA 3405, NAPA 3693 KuduParts $24.00 FridayParts $25.66
Coolant filterP554071Coolant Filter, Spin-OnCUMMINS 209604, CUMMINS 209606, NAPA 4071, WALGAHN-MOTORENTECHN 00811412 FridayParts $397.60
Coolant filterP554073Coolant Filter, Spin-OnCUMMINS 209605, CUMMINS 209607, NAPA 4073, VERSATILE 00104040 KuduParts $40.00

Maintenance & consumables

for the Cummins/Onan NT855
ItemSpecCapacityPart #Interval
Air filter123459200 hr Amazon eBay
Fuel filter123458200 hr Amazon eBay
Oil filter123457200 hr Amazon eBay $17.99
Battery123462200 hr Amazon eBay
Belt123461200 hr Amazon eBay $18.95
Coolant16.5 Liters123460200 hr Amazon eBay
Coolant filterB342-12 hr Amazon eBay
Oil11.2 L—200 hr
Spark plug123463200 hr Amazon eBay

Service intervals

23
ItemActionHoursMonthsNotes
GensetInspect8 hrInspect for oil, fuel, cooling and exhaust system leaks. Check exhaust system audibly and visually with set running (footnote X1).
Air CleanerCheck50 hrClean if required. Perform more often in dusty conditions (footnote X2).
Battery Charging SystemCheck50 hr
Charge Air PipingCheck50 hr
Coolant HeaterCheck50 hrColumn alignment in source table is ambiguous; interval as printed in schedule columns.
Coolant LevelCheck50 hr
Crankcase oilChange50 hrFirst service — Break-in: drain and replace crankcase oil after first 50 hours on new generator sets
Fuel LevelCheck50 hr
Oil LevelCheck50 hr
Anti-freeze and DCA ConcentrationCheck100 hrRefer to engine operation and maintenance manual for procedure (footnote X5).
Drive Belt TensionCheck100 hrVisually check belt for evidence of wear or slippage; replace if hard or brittle (footnote X3). Refer to engine operation and maintenance manual (footnote X5).
Exhaust Condensate TrapDrain100 hr
Fuel Filter(s)Drain100 hrDrain 1 cup or more of fuel to remove water and sediment (footnote X4); refer to engine operation and maintenance manual (footnote X5).
Water and Sediment from Fuel TankDrain100 hrDrain 1 cup or more of fuel to remove water and sediment (footnote X4).
Air Cleaner ElementChange250 hrPerform more often in dusty conditions (footnote X2).
Coolant FilterChange250 hrRefer to engine operation and maintenance manual for procedure (footnote X5).
Crankcase BreatherClean250 hrRefer to engine operation and maintenance manual for procedure (footnote X5).
Crankcase oil and filterChange250 hr12 moTable 7-1. If genset used for prime power, change every 6 months or 250 hours. If standby, change every 12 months or 250 hours, whichever comes first.
Starting BatteriesCheck250 hr
Cooling SystemClean500 hrRefer to engine operation and maintenance manual for procedure (footnote X5).
Fuel FiltersChange500 hrRefer to engine operation and maintenance manual for procedure (footnote X5).
Radiator Hoses for Wear & CracksCheck500 hr12 mo
Rupture basin leak detect switchTest12 moSome areas may require weekly inspections by safety code.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

60
TypeItemValueUnitCondition
ClearanceAngular alignment maximum T.I.R.0.001inch per inch of radius (center of shaft to indicator axis)measuring deflection to bolt heads
ClearanceCoolant level below radiator cap openingabout two inches (50 mm)in (mm)engine cold
ClearanceFloat switch assembly float lift clearance below C-clip stop1/8inch (3 mm)use a feeler gauge
ClearanceGenerator-to-engine angular alignment (T.I.R.).001 in. per inch of radius (center of shaft to indicator axis), maximumin750 kW gensets and larger
ClearanceMPU sensor to gear tooth adjustmentback out one quarter turnturnafter contacting gear tooth
ClearanceVibration isolator base elevation difference0.25inch (6 mm)all isolator bases within this elevation of each other
ClearanceVibration isolator clearance between top plate and base0.25inch (6 mm)nominal or greater
ClearanceVibration isolator top plate to base clearance0.25inch (6 mm)nominal, or greater
GapAir cleaner cleaning nozzle distance1inch (25 mm)at least
GapAngular alignment total indicator reading (T.I.R.)0.001inch per inch of radiusmaximum
GapFloat switch lift to test open1/8inchbelow C-clip stop
GapMPU sensor to flywheel ring gear toothback it out one quarter turnturnsensor threaded in until it just touches gear tooth
OtherAVR Droop setting5% at full load, 0 PF
OtherAVR voltage regulation (load regulation)approximately ±0.5% RMS
OtherAngular alignment maximum T.I.R..001inch per inch of radiuscenter of shaft to indicator axis
OtherAngular alignment maximum T.I.R..001 inches per inch of radiusin/incenter of shaft to indicator axis
OtherBattery electrolyte specific gravity, charge if below1.215
OtherBattery electrolyte specific gravity, fully charged (corrected)1.260corrected; add 0.004 per 10°F above 80°F (27°C)
OtherBattery specific gravity1.260specific gravityat 80 F (27 C)
OtherBattery specific gravity (high ambient, above 95F/35C)1.225recommended to reduce electrolyte loss
OtherBattery specific gravity (recharge threshold)below 1.260
OtherBattery specific gravity, fully chargedapproximately 1.260specific gravityat 80 F (27 C)
OtherBreather cleaning compressed air30psimaximum (OSHA)
OtherCool-down at idle timer range0 to 30minutes
OtherCycle cranking option15-second crank, 15-second rest, 3 cycles
OtherFuel lift height limit6feet(1.8 meters) between fuel lift pump and bottom of dip tube
OtherGOV GAIN default value for paralleling applications70%
OtherMaximum cranking voltage drop2voltsdifference between battery and starter terminals while cranking
OtherOver/Under Frequency Sensor Module - Over Hz Set, 50 Hz nominal55Hzreset 53 Hz
OtherOver/Under Frequency Sensor Module - Over Hz Set, 60 Hz nominal65Hzreset 63 Hz
OtherOver/Under Frequency Sensor Module - Under Hz Set, 50 Hz nominal45Hzreset 47 Hz
OtherOver/Under Frequency Sensor Module - Under Hz Set, 60 Hz nominal55Hzreset 57 Hz
OtherOver/Under Voltage Sensor Module time delaytypically 25 percent, approximately 2.5seconds
OtherOvercrank cranking limit75secondsthree 15-second cranking cycles with two 15-second rest periods
OtherOvercrank cranking limit (standard control)75seconds
OtherREG VHZ (underfrequency roll-off) adjustable range1 through 50; normal range 7 through 21
OtherRated To Idle delay range0 to 10secondsdefault = 0; Beginning Version 2.303
OtherStart Delay setting range0 to 300secondsdefault = 0
OtherStart delay adjustment range0 to 300seconds
OtherStop Delay setting range0 to 600secondsdefault = 0
OtherStop delay adjustment range0 to 600seconds
OtherUnder Frequency Roll Off (UFRO) knee point, 50 Hz units48 to 49Hz
OtherUnder Frequency Roll Off (UFRO) knee point, 60 Hz units58 to 59Hz
OtherUnder-frequency roll-off threshold (UFRO)typically 59 Hz for 60 Hz applications and 49 Hz for 50 Hz applicationsHzAVR UFRO pot preset
OtherWarm-up at idle time delay range0-300seconds
PressureAir cleaner cleaning compressed air30psi (207 kPa)maximum
PressureEngine oil pressure - K19 normal50-70psi (345-482 kPa)run mode
PressureEngine oil pressure - K38 normal45-65psi (310-448 kPa)run mode
PressureEngine oil pressure - K50 normal50-70psi (345-482 kPa)run mode
PressureEngine oil pressure - L10/M11 normal30-50psi (207-345 kPa)run mode
PressureEngine oil pressure - NTA 855 normal35-50psi (241-345 kPa)run mode
PressureEngine oil pressure - V28 normal50-90psi (345-620 kPa)run mode
PressureEngine oil pressure shutdown limit - L10/M1120psi (138 kPa)run mode value
PressureEngine oil pressure shutdown limit - L10/M118psi (55 kPa)idle mode value
PressureEngine oil pressure warning limit - L10/M1112psi (83 kPa)idle mode value
PressureEngine oil pressure warning limit - L10/M1125psi (172 kPa)run mode value
PressureIdle oil pressure shutdown limit12psi (83 kPa)
PressureIdle oil pressure shutdown limit (PCC)12psi (83 kPa)idle
PressureIdle oil pressure warning limit15psi (104 kPa)
PressureIdle oil pressure warning limit (PCC)15psi (104 kPa)idle

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
CoolantWater/antifreeze mixture precharged with Diesel Coolant Additive (DCA)Engine manufacturer's coolant requirements; do not use antifreeze with anti-leak additives62.0 LStandard radiator capacity 16.5 gallons (62 L) for 275 DFBF
Coolantsoft water / E.G. / DCA mixtureCooling system to be filled with soft water/E.G./DCA mixture (on-site review checklist).
CoolantNFPA 110above 4°CNFPA 110 recommends engine jacket water coolant heaters where minimum ambient is above 40°F (4°C); coolant maintained at minimum 90°F (32°C). Cooling system capacity with standard radiator: DFAB/DFAC 13 Gal (49 L); DFBF 13.5 Gal (51 L); DFCC 13.5 Gal (51 L); DFCE 15 Gal (57 L).
Engine oilAPI Class CC/CD42.0 quartsOil capacity with filters (all models)
Engine oilSAE 5W syntheticAPI Class CC/CD; pour point 9 F (5 C) below lowest expected temperature; viscosity 10,000 mPa-s max at -31 F (-35 C) and 4.1 mm2/s min at 212 F (100 C)below -25°CExtreme cold: consistently below -13 F (-25 C) with no provision to keep engine warm
Engine oilSAE 10W-30API Class CC/CD, max 1.85% sulphated ash-23°C to -10°CTable 5-2; Specification section lists 10W-30 for -13 F to 95 F (-25 C to 35 C)
Engine oilSAE 15W-40API Class CC/CD, max 1.85% sulphated ashabove -10°CTable 5-2: 14 F (-10 C) and above; Specification section: -14 F (-10 C) and above
Engine oilSAE 20W-40API Class CC/CD, max 1.85% sulphated ashabove 0°C32 F (0 C) and above
FuelDiesel fuelDo not use zinc coated or copper fuel lines with diesel fuel. Fuel connection at the engine should be made with an approved flexible line.
FuelASTM No. 2 dieselCummins engine Operation and Maintenance Manual alternate diesel fuelsCummins engines normally use ASTM No. 2 diesel fuel. Never use galvanized or copper fuel lines, fittings or fuel tanks.
FuelASTM No. 2 diesel fuelASTM No. 2Cummins engines normally use ASTM No. 2 diesel fuel; they will operate on alternate diesel fuels within the specifications shown in the Cummins engine Operation and Maintenance Manual. Never use galvanized or copper fuel lines, fittings or fuel tanks.
FuelDieselDay tank fuel transfer pump maintains reservoir of diesel fuel in the day tank.
FuelNo. 2 Diesel Fuel; Bio-Diesel B5-B20 approved with recommendationsASTM D975 (post-storage purge fuel)Bio-diesel not recommended for Emergency Standby RV use (low annual hours, critical start nature).
FuelNo. 2 diesel (No. 1 acceptable)Filter or strain fuel as tank is filled; keep tanks full to avoid condensation
GreaseLithium based greaseMobilux No. 2 or Shell Alvania R32.74 oz (81 ml)Generator end bearing. Temperature range -22F to +248F (-30C to +120C). Grease should be equally divided between the bearing, bearing cap cavity, and bearing cartridge cavity.
GreaseLithium based-30°C to 120°C81.0 mlMobilux No. 2 or Shell Alvania R3; generator end bearing; temperature range -22 F to +248 F (-30 C to +120 C); grease divided between bearing, bearing cap cavity and cartridge cavity.
GreaseLithium based grease, Mobilux No. 2 or Shell Alvania R3-30°C to 120°C2.74 oz (81 ml)End bearing lubricant; grease equally divided between bearing, bearing cap cavity and bearing cartridge cavity.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Fault codes

80
CodeNameMeaningSeverityAction
101IDLE MODEIndicates that the engine is operating in idle mode. Grounding the engine idle input causes generator build-up to be inhibited and the engine to be governed at 800 RPM.WarningRemove ground from engine idle input to return to normal speed and voltage.
102EMERGENCY STOPLocal or remote Emergency Stop.ShutdownTurn the switch clockwise and allow it to pop out (local only); move the Run/Off/Auto switch to Off; press the Reset switch; select Run or Auto as required. Can be reset only at the PCC front panel.
1122Rated/Idle Trans
1123Shutdown After BSShutdown fault occurred while Battle Short was enabled and then disabled.ShutdownReview Fault History and perform corrective action.
1124Delayed ShutdownShutdown fault became active while Delayed Shutdown feature was enabled.WarningReview Fault History and perform corrective action.
1131Battle Sh ActiveControl is in Battle Short mode.WarningBypasses several critical fault shutdowns for emergency operation.
121Speed Signal LostMag pickup speed indication is not being sensed.ShutdownRestart and check RPM on the digital display.
1311Customer Input #1The nature of the fault is an optional customer selection. Example inputs: Low Fuel Day Tank, Water In Fuel, Ground Fault, Low Starting Hydraulic Pressure, Low Starting Air Pressure, etc.Enable/disable input (Default: enable); Status, Warning or Shutdown (Default: #1-None, #2 thru #4-Warning); Active closed or open (Default: closed [ground]); change display name up to 19 characters (Default: #1-Customer Fault 1).
1311, 1312, 1317, 1318CUSTOMER INPUT #1 - #4Optional customer-selected fault input is active.WarningCheck external wiring and active input (closed/open) selection.
1312Customer Input #2Default display name: Ground Fault.Configurable input; defaults #2 thru #4 = Warning.
1317Customer Input #3Default display name: Low Fuel.Configurable input; defaults #2 thru #4 = Warning.
1318Customer Input #4Default display name: Rupture Basin Fault.Configurable input; defaults #2 thru #4 = Warning.
1334Crit Scaler ORIncorrect feature or calibration entered into control.ShutdownReload correct calibration.
1335Noncrit Scaler ORIncorrect feature or calibration entered into control.WarningReload correct calibration.
1337No Message
135Oil Pressure Sensor HEngine oil pressure sender signal is shorted high.WarningCheck sender/connectors/wires.
141Oil Pressure Sensor LEngine oil pressure sender signal is shorted low.WarningCheck sender/connectors/wires.
1416Fail To ShutdownGenset continues to run after shutdown command.WarningCheck Battle Short feature enabled condition.
1417Powr Down ErrorIndicates that the controller can not power down because of some unknown condition. Possible drain on battery.WarningContact an authorized service center for service.
143Pre-Low Oil PresIndicates engine oil pressure has dropped to an unacceptable level. If generator is powering critical loads and cannot be shut down, wait until next shutdown period and then follow code 415 procedure.WarningIf powering critical loads and cannot be shut down, wait until next shutdown period and follow code 415 procedure.
1433Emergency StopLocal Emergency Stop.ShutdownTo reset: pull the button out; move the O/Manual/Auto switch to O; press the front panel Fault Acknowledge/Reset button; select Manual or Auto as required.
1434Remote E-StopRemote Emergency Stop.ShutdownSee code 1433 to reset.
1435Low Coolant TempWarning occurs when engine coolant temperature is 70°F (21°C) or lower. In applications where the ambient temperature falls below 40°F (4°C), Low Coolant Temp may be indicated even though the coolant heaters are operating.WarningIndicates engine coolant heater is not operating or is not circulating coolant. Check that coolant heater is connected to power supply (check for blown fuse or disconnected heater cord). Check for low coolant level and replenish if required; look for possible coolant leakage points and repair as required.
1438Fail To CrankIndicates possible fault with control, speed sensing or starting system.ShutdownSee code 441 for corrective action.
144Coolant Sensor HighEngine coolant temperature signal is shorted high.WarningCheck sender/connectors/wires.
1442Weak BatteryIndicates that during cranking, the battery voltage is at or below the weak battery warning trip point for a time greater than or equal to the weak battery set time.WarningSee code 441 for corrective action.
1443Battery FailedDead battery - engine will not start.ShutdownSee code 441 for corrective action.
1444KW OverloadGenerator output power exceeded 105% of genset rating.WarningCheck load and load lead connections; check CTs.
1445Short CircuitGenerator output current has exceeded 175% of rated.ShutdownCheck load and load lead connections.
1446High AC VoltageOne or more phase voltages exceeded 130% of nominal.ShutdownCheck fault simulation, load removal, threshold settings, Base board/generator.
1447Low AC VoltagePhase voltages dropped below 85% of nominal for 10 seconds.ShutdownCheck overload, output terminal connections, PMG/field wiring, rectifier diodes.
1448Under FrequencyEngine speed dropped below 90% of nominal for 10 seconds.ShutdownCheck fuel supply, intake air supply and load.
1449Over FrequencyFrequency is 10% above base frequency for 20 seconds.WarningCheck fuel or air delivery; check connections.
145Coolant Sensor LowEngine coolant temperature signal is shorted low.WarningCheck sender/connectors/wires.
1452Gen CB Not CloseGenset circuit breaker (S2) failed to close when PTC is enabled.WarningRefer to Section 5 troubleshooting charts.
1453Gen CB Not OpenGenset circuit breaker (S2) failed to open when PTC is enabled.WarningRefer to Section 5 troubleshooting charts.
1459Reverse PowerImproper CT phasing.ShutdownCheck wiring to voltage sense circuit; refer to CT Installation in Section 6.
146Pre-High Coolant TempIndicates engine has begun to overheat (coolant temperature has risen to an unacceptable level).WarningReduce load; check air inlets/outlets; follow code 151 if engine can be stopped.
1461Loss Of FieldLoss of field (electric) due to reverse kVAR.ShutdownCheck excitation circuit.
1466Modem FailureControl cannot communicate with the modem.WarningCheck for open, short to ground and loose connections to the modem.
1468Network ErrorMomentary loss of communication from the LonWorks Network.WarningRefer to LonWorks Network publications.
1469Speed/Hz MatchMeasured speed and measured AC output frequency do not agree.ShutdownCheck calibration file.
1471Over CurrentGenerator output current exceeded 110% of rated for 60 seconds.WarningCheck load and load lead connections.
1472Over CurrentOutput current exceeded 110% of rated and time/current calculation initiated shutdown.ShutdownCheck load and load lead connections.
151High Coolant TempIndicates engine has overheated (coolant temperature has risen above the shutdown trip point). Allow engine to cool down completely before proceeding.ShutdownCheck coolant level and replenish if low; look for coolant leakage points and repair. Check for obstructions to cooling airflow. Check fan belt and repair or tighten if necessary. Check blower fan and circulation pumps on remote radiator installations. Reset control and restart after correcting problem.
197Low Coolant LevelIndicates engine coolant level has fallen below the warning trip point (optional).WarningIf powering critical loads and cannot be shut down, wait until next shutdown period, then follow code 235 procedure. If engine can be stopped, follow code 235 procedure.
200LOW OIL PRESSUREIndicates engine oil pressure has dropped to an unacceptable level.WarningIf powering critical loads, wait until next shutdown period then follow 201 procedure.
201LOW OIL PRESSUREIndicates engine oil pressure has dropped below the shutdown trip point.ShutdownCheck oil level, lines and filters; replenish if low; reset control and restart; contact service center.
204OIL PRES SENDERIndicates that the control has sensed that the engine oil pressure sender is out of its working range.WarningCheck that the engine oil pressure sender is properly connected. Contact service center.
210LOW COOLANT TEMPWarning occurs when engine coolant temperature is 70°F (21°C) or lower.WarningWarning LED illuminates. Check the coolant heaters for proper operation; if operating properly, other precautions may be necessary to warm the engine before applying a load.
211HIGH COOLANT TEMPIndicates the engine coolant temperature is getting close to the recommended maximum temperature limit: 215° F (102° C) − standby or 207° F (97° C) − primary.WarningReduce load; check air inlets/outlets and remove obstructions.
212Oil Temp Sensor HIndicates engine has overheated (coolant temperature has risen above the shutdown trip point: 215 F (102 C) - standby or 207 F (97 C) - primary).WarningCheck sender/connectors/wires.
213Oil Temp Sensor LResistance of the coolant temperature sender is out of range.WarningContact an authorized service center.
214LOW COOLANT LVLIndicates engine coolant level has fallen below the trip point.WarningCheck coolant level in radiator and coolant recovery bottle; replenish if low; look for leaks.
215LOW COOLANT LVLIndicates engine coolant level has fallen below the trip point.ShutdownAllow engine to cool; check coolant level and replenish; look for leaks and repair; reset and restart. Shutdown will not occur in Idle mode.
220MAG PICKUPMag pickup speed indication not sensed or does not match generator set output frequency.ShutdownRestart and check RPM; check PCC model setting; inspect and test MPU.
221FAIL TO CRANKPossible fault with control or starting system.ShutdownCheck fuse F3 on the Engine Interface board; check battery cable connections; recharge or replace the battery.
222OVERCRANKPossible fuel system problem.ShutdownCheck for empty fuel tank, leaks, plugged fuel lines; replace dirty fuel or air filter; reset and restart.
223OVERSPEEDIndicates engine has exceeded normal operating speed. (115% ±1% of nominal).ShutdownContact an authorized service center.
224FAIL TO SYNCHRONIZEGenerator set has not synchronized to the system bus within the allowable time frame.WarningCheck governor system stability; adjust governing and synchronizer parameters; check fuel system.
226FAIL TO CLOSEParalleling breaker has been given a signal to close, but has not closed properly.ShutdownVerify breaker charging mechanism; check close signal; verify auxiliary contact signals.
230LOW DC VOLTAGEIndicates battery voltage is below 10 VDC.WarningRecharge or replace the battery; check the battery charger fuse. Clean and tighten battery cable connections. Check engine DC alternator; replace if normal charging voltage is not obtained. Check float level if applicable.
231HIGH DC VOLTAGEIndicates battery voltage exceeds 32 VDC.WarningLower battery charger float level if applicable; check engine DC alternator.
232WEAK BATTERYIndicates battery voltage drops below 60% of nominal for two seconds, during starting.WarningSee Warning message 230, LOW DC VOLTAGE.
2327PTC FaultPTC module or communication link is not working properly.WarningCheck PTC module power, ground shield, cycle control power.
2329Low S1 FrequencyLow utility (S1) frequency.WarningCheck S1 AC inputs and wiring to PTC at TB5; check sensor set points.
2331Low S1 VoltageLow utility (S1) voltage.WarningCheck S1 AC inputs and wiring to PTC at TB5; check pickup/dropout set points.
2335Excitation FaultLoss of all three voltage sense leads or failure in excitation circuit.ShutdownCheck field wiring (X1 and X2) for shorts or opens.
2336Memory ErrorControl memory error; data corruption of critical operating parameters.ShutdownTry reloading calibration file.
2337Pwr Tran DisabledPTC module available but PTC feature not enabled.WarningEnable PTC feature with InPower; cycle control power.
2338Pwr Tran FailureControl could not communicate with the PTC module.WarningCheck PTC module power and cable ground shield; cycle control power.
2339Pwr Down EnabledPower Down (sleep) enabled but PTC module or network board is active.WarningNone required.
234OverspeedEngine has exceeded normal operating speed.ShutdownCheck for large block load removal, flammable vapors or leaking turbocharger seals.
2341High Control TempControl temperature above 158 F (70 C) for longer than set time.WarningCheck genset room air flow.
2342Too Long In Idle (10 min.)Indicates genset has been in Idle mode too long (10 minutes maximum).WarningExit idle mode.
235Low Coolant LevelIndicates engine coolant level has fallen below the shutdown trip point (optional). Allow engine to cool down completely before proceeding.ShutdownCheck coolant level and replenish if low; reset control.
2358High S1 VoltageUtility (S1) voltage increased above the over-voltage threshold.WarningMeasure S1 AC inputs at PTC module; check sensor set points.
2396S1 CB Not CloseUtility contact (S1) failed to close with PTC enabled.WarningRefer to Section 5 troubleshooting charts.
2397S1 CB Not OpenUtility contact (S1) failed to open with PTC enabled.WarningRefer to Section 5 troubleshooting charts.
240LOW FUEL−DAYIndicates day tank fuel supply is running low.WarningCheck fuel supply and replenish as required.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Adjust Start/Stop Delays (PCC Adjust Menu) adjustment

⚠ Electrostatic discharge will damage circuit boards. Always wear a grounding wrist strap when working inside control box.

  1. Press the button next to ADJUST in the Main Menu; the VOLTAGE submenu appears.
  2. Press the button next to >> to move through VOLTAGE and FREQUENCY to the START DELAY submenu.
  3. Use the buttons next to the up and down symbols to set the start delay.
  4. Press >> to move to the STOP DELAY submenu and set the stop delay.
  5. Press >> to move to the IDLE SPEED submenu and set idle speed (only in idle mode).
  6. Press >> to move to SAVE/EXIT; select SAVE then EXIT to return to Main menu.
Adjusting Values/Parameters (PCC Adjust Menu) adjustment
  1. Press the button next to the arrow symbol in the display until the + and - symbols are displayed.
  2. If necessary, press the button next to the arrows to move to the numeric character to change.
  3. Press + to increase the value or select the parameter; press - to decrease the value or select the parameter.
  4. Press the save symbol to save changes; changes are not saved if Home or Previous Main Menu is pressed first.
Aligning Generator with Engine (Angular Alignment) adjustment

⚠ Accidental starting of the generator set during this procedure presents the hazard of severe personal injury or death.

Tools: Dial indicator, Shims

  1. Disconnect the negative (-) battery cable(s) before beginning.
  2. Fasten a dial indicator to the generator shaft or cooling fan with the sensing point on the capscrew head or flat surface of the drive disc at the bolt circle diameter.
  3. Bar the engine over in a clockwise rotation as viewed from engine flywheel; do not allow it to roll back on compression.
  4. Determine the total indicator reading (T.I.R.) as the sum of the maximum positive and negative dial indicator readings over one revolution.
  5. Measure the distance from the center of the generator shaft to the indicator measuring point.
  6. Measure the distance from the generator side of the flex discs to the center of the generator mounting bolt.
  7. Compare the distances; multiply this ratio times one half the T.I.R. to approximate the amount of shims to remove or add.
Angular Alignment Procedure adjustment

⚠ Accidental starting of the generator set during this procedure presents the hazard of severe personal injury or death. Make sure to disconnect the negative (-) battery cable(s) before beginning.

Tools: Dial indicator, Wooden shims

  1. Disconnect the negative (-) battery cable(s) before beginning.
  2. Fasten a dial indicator to the generator shaft or cooling fan with sensing point on capscrew head or flat surface of drive disc at bolt circle diameter.
  3. Bar the engine over in a clockwise rotation as viewed from engine flywheel; do not allow it to roll back on compression.
  4. Record maximum positive and negative dial indicator readings as the engine completes one revolution.
  5. T.I.R. equals the sum of the maximum positive and negative readings.
  6. Maximum T.I.R. should not be more than .001 inch for each inch of radius.
  7. Remove equal shims from under both generator mounting feet to lower the generator.
Angular Alignment Procedure (750 kW Gensets and Larger) adjustment

⚠ Accidental starting of the generator set during this procedure presents the hazard of severe personal injury or death. Make sure to disconnect the negative (-) battery cable(s) before beginning.

⚠ Do not bar engine over by prying on fan blade.

Tools: Dial indicator, Shims

  1. Disconnect the negative (-) battery cable(s) before beginning.
  2. Fasten a dial indicator to the generator shaft or cooling fan, with the sensing point on the capscrew head or drive disc flat surface at bolt circle diameter.
  3. Bar the engine over clockwise as viewed from the engine flywheel; do not allow it to roll back on compression.
  4. Total indicator reading (T.I.R.) is the sum of the maximum positive and negative readings as the engine completes one revolution.
  5. To lower the generator, remove equal shims from under both generator mounting feet; approximate shim amount from the distance ratio.
Angular Alignment Procedure (Generator to Engine) adjustment

⚠ Accidental starting during this procedure presents the hazard of severe personal injury or death.

⚠ Do not bar engine over by prying on fan blade.

Tools: dial indicator

  1. Disconnect the negative (-) battery cable(s) before beginning.
  2. Fasten a dial indicator to the generator shaft or cooling fan with sensing point resting on the drive disc capscrew head/flat surface at the bolt circle diameter.
  3. Bar the engine over in a clockwise rotation as viewed from the engine flywheel; do not allow it to roll back on compression at the end of travel of each reading.
  4. Record the total indicator reading (T.I.R.) as the sum of the maximum positive and negative dial indicator readings over one engine revolution.
  5. Compare the measured T.I.R. to the maximum allowed (.001 in. per inch of radius from center of shaft to indicator axis); add or remove shims under the generator mounting feet to correct.
Axial Alignment Procedure adjustment

Tools: Dial indicator, Magnetic base or clamp

  1. Check axial alignment only when an objectionable vibration is present after angular alignment.
  2. Fasten dial indicator holding device to skid base, engine block, or generator shell with a magnetic base or clamp; rest sensor on generator shaft hub.
  3. Bar the engine over clockwise through a couple of rotations; record indicator readings at eight equally spaced points around the shaft diameter.
  4. To correct out-of-tolerance T.I.R., remove the drive disc capscrews, mark discs and flywheel, rotate 180 degrees from original location, retorque, and recheck.
  5. If unchanged, rotate the discs to 30, 60 or 90 degrees from their original location.
Axial Alignment Procedure (Generator to Engine) adjustment

Tools: dial indicator

  1. Fasten a dial indicator holding device to the skid base, engine block, or generator shell with the sensor point resting on the generator shaft hub.
  2. Bar the engine over in a clockwise rotation through a couple of rotations, recording indicator readings at eight equally spaced points around the shaft diameter to obtain axial T.I.R.
  3. Reduce the measured T.I.R. runout by one half if excessive vibration remains after angular alignment.
Electric Governor Preliminary Adjustment adjustment
  1. Turn idle speed potentiometer clockwise 20 turns, then 10 more turns.
  2. Turn run speed potentiometer clockwise 20 turns, then 10 more turns.
  3. Turn gain potentiometer fully counterclockwise.
  4. Turn droop potentiometer fully counterclockwise for isochronous operation.
Governor Calibration Checks adjustment

Tools: Frequency meter or tachometer, Jumper wire

  1. Start the generator set.
  2. Adjust engine no-load speed to the desired allowable speed droop using the Run Speed potentiometer.
  3. With no load, turn GAIN clockwise slowly until engine speed oscillates.
  4. Reduce GAIN slowly counterclockwise until engine speed is stable.
  5. Upset the governor by momentarily shorting terminals 7 and 10 on the governor control.
  6. Apply and remove loads to check generator set response.
Governor Gain Adjustment adjustment
  1. Close the main line circuit breaker and apply approximately 1/4 rated load.
  2. Verify engine speed is constant.
  3. Turn GAIN potentiometer clockwise slowly until engine speed is not constant.
  4. Turn potentiometer counterclockwise until constant speed is achieved.
  5. Turn counterclockwise an additional 1/2 division.
HC4-7 Axial Alignment Procedure adjustment

Tools: Dial indicator with magnetic base or clamp

  1. Check only when an objectionable vibration is present.
  2. Fasten dial indicator holding device to skid base, engine block, or generator shell with magnetic base or clamp.
  3. Position sensor point on the generator shaft hub.
  4. Bar the engine over in a clockwise rotation as viewed from engine flywheel through a couple of rotations.
  5. Record indicator readings in eight equally spaced points around the shaft diameter.
  6. Remove the capscrews connecting drive discs and flywheel and mark discs and flywheel.
  7. Rotate engine or generator so drive disc holes are repositioned 180 degrees from original location.
  8. Put capscrews back in and retorque. Recheck shaft alignment.
  9. If runout unchanged, rotate discs to 30, 60 or 90 degrees from original location.
  10. If T.I.R. does not improve, inspect flywheel pilot and drive disc runouts.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
12 lead generator setsLoad wires are routed through the CTsReconnectable gensets (12 leads) have dual secondary CTs (3 pins); CT wire 2/3 to pin 2 (high voltage) or pin 3 (low voltage).
6 lead generator setsGenerator output leads are routed through the CTsNon-reconnectable gensets (6 leads) have single secondary CTs (2 pins).
Cummins PowerCommand generic AC Reconnect Wiring Diagram 625-2755 (Rev. D) and 625-3100 (Rev. F)Applies to models DFAA, DFAB, DFAC, DFBF, DFCB, DFCC, DFEB, DFEC, DFFB, DFGA, DFGB, DFJA, DFJB, DFJC, DFJD, DFLB, DFLC, DFLD, DFMB (625-2755) and models DFAA-DFMB plus DFCE, DFED, DQAA, DQAB, DQBA, DQBB (625-3100).
Current transformers CT21-U load leads (A phase), CT22-V load leads (B phase), CT23-W load leads (C phase)CT secondary wire marked 1 to pin 1; wire marked 2/3 to pin 2 for high voltage gensets or pin 3 for low voltage gensetsCT dot must face toward the generator; CTs have dual secondaries (3 pins).
Generator load terminals stamped U, V, W and N (U=L1, V=L2, W=L3, N=L0)Stranded load wires bolted to generator reconnection terminal block or circuit breaker lugsAvailable generator output voltages and maximum current ratings are specified on the generator set nameplate; line-to-neutral is the lower voltage, line-to-line the higher. Reconnection diagram is located on the upper side cover of the control housing.
A (U)CT21U load leads (A phase)CT dot must face the generator; CT terminal 1 connects to metering circuit, terminal 2/3 to ground.
B (V)CT22V load leads (B phase)CT dot must face the generator; terminal 1 to metering circuit, terminal 2/3 to ground.
C (W)CT23W load leads (C phase)CT dot must face the generator; terminal 1 to metering circuit, terminal 2/3 to ground.
110 V - 120 V L-N1Single phase, 2-wirePTC module jumper locations
190 V - 240 V L-L3Three phaseUse PTC module 0300-5382-01; 50/60 Hz
200 V - 240 V L-L1Single phase, 3-wirePTC module jumper locations
380 V - 600 V L-L3Three phaseUse PTC module 0300-5382-02; 50/60 Hz

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

How many kW is the Cummins/Onan DFBF?

The Cummins/Onan DFBF is rated 275 kW standby (344.0 kVA).

Which engine powers the Cummins/Onan DFBF?

The Cummins/Onan DFBF is powered by the Cummins/Onan NT855 engine.

What kind of fuel does the Cummins/Onan DFBF run on?

The Cummins/Onan DFBF runs on diesel.

What's the oil capacity on a Cummins/Onan DFBF?

The Cummins/Onan NT855 engine in the Cummins/Onan DFBF has an oil capacity of 40.0 liters.

What is the cooling system capacity of the Cummins/Onan DFBF?

The Cummins/Onan DFBF cooling system holds 51 liters (13.5 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the continuous rating of the Cummins/Onan DFBF?

The Cummins/Onan DFBF is rated 250 kW prime (313 kVA), against 275 kW standby.

How much does the Cummins/Onan DFBF weigh?

The Cummins/Onan DFBF has a dry weight of 3289 kg (7250 lb).

What size battery does the Cummins/Onan DFBF need?

The Cummins/Onan DFBF uses 2 batteryies, 12 V each, 1400 CCA, group 8D, per the manufacturer specification sheet.

What oil filter does the Cummins/Onan DFBF use?

The Cummins/Onan DFBF uses oil filter part number 123457.

What fuel filter fits the Cummins/Onan DFBF?

The Cummins/Onan DFBF uses fuel filter part number 123458.

What air filter does the Cummins/Onan DFBF use?

The Cummins/Onan DFBF uses air filter part number 123459.

Troubleshooting

6

Fault codes

CodeMeaningCauseRemedy
F01Generator does not startPossible causes include low battery voltage, faulty starter motor, or incorrect wiringCheck the battery voltage; replace if necessary. Test the starter motor. Verify all connections are correct and secure. Refer to the fault code table for more details.
F02Generator produces insufficient power outputPossible causes include clogged air filter, low fuel level, or malfunctioning alternatorClean or replace the air filter. Check the fuel level; refill if necessary. Inspect the alternator for any signs of damage or wear. Refer to the fault code table for more details.
F03Generator overheatsPossible causes include clogged cooling system, low coolant level, or malfunctioning thermostatClean the radiator fins and check for debris blockages. Check the coolant level; top up if necessary. Test the thermostat to ensure it is functioning correctly. Refer to the fault code table for more details.

Symptoms & remedies

SymptomRemedy
Status Indicators are not functioning properlyCheck the status indicators and ensure they are correctly connected. Refer to the troubleshooting table for further assistance.
Line Circuit Breaker is tripped or malfunctioningReset the line circuit breaker if it has tripped. If the issue persists, refer to the troubleshooting table for further steps.
Control and diagnostics via network or PC are not workingEnsure that the network connection is stable and correct. Check the control panel settings and software compatibility. Refer to the troubleshooting table for specific issues.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing. Full Cummins/Onan DFBF troubleshooting guide (116 entries) →

Parts

108
Part #DescriptionQtySystem
0300-4623-08DFBF (600V)1Current transformer Amazon eBay
0300-4623-23DFBF BR (0-480V)1Current transformer Amazon eBay
140-2389140-2391 1 140-2390 1 140-2392 1 140-2393 1 140-1548 1 140-1545 1 c 503-1575 186917 C1Air filter Amazon eBay
140-2391Element - Air Cleaner (Standard)1Air filter Amazon eBay
191-1858Starter (24VDC)1Starter Amazon eBay
191-1982Pulley, Alternator1Alternator Amazon eBay FridayParts $40.00
191-1983-02Alternator, 24 Volt Spec B-O (Prestolite)1Alternator Amazon eBay
193-0432Sender, Oil Temperature (S2 Engine Block, E4 Oil Pan)2Sensor Amazon eBay
193-0447-01Sender, Water Temperature (E2)1Sensor Amazon eBay
193-0448Sender, Oil Pressure1Sensor Amazon eBay
1S0A713Bracket, Overspeed Switch1Bracket Amazon eBay
1S0A717Switch Assy., Overspeed1Switch Amazon eBay
204493Ring, Collector1Ring Amazon eBay FridayParts $27.10
2110153Bell, End - Alt, to Exciter1Bell Amazon eBay
23201396Support, Gen. Mtg.1Support Amazon eBay
232A1817Generator3Generator Amazon eBay
2340116Cover, Exciter1Cover Amazon eBay
234070Rig Assy., Brush- Incl. Brushes, & Contact Point Band, Gen. - Front Portion(Narrow)1Brush Amazon eBay
2348115Bracket, Mtg. - Volt. Cont. Reactor1Bracket Amazon eBay
234875Bracket, Gate Reactor Mtg.1Bracket Amazon eBay
234C1343-Phase1Phase Amazon eBay
234C1373-Phase1Phase Amazon eBay
234C140Single Phase1Phase Amazon eBay
234C141Single Phase1Phase Amazon eBay
2I4AMBrush4Brush Amazon eBay
302P421Scale Reads 0-3001Voltmeter Amazon eBay $240.00
302P465RESISTOR-STABILIZING1Meter Amazon eBay
302P466For 220/380-V, 3-Ph, 60-Cycle (Model H)1Meter Amazon eBay
302P468For 120/208-V,120/240-V, & 347/600-V 3PH. 50 Cy!. (825-Ohm, 75-Watt)1Meter Amazon eBay
302P469For 220/380-V, 3Ph. 50-Cycle1Meter Amazon eBay
302P470For 277/480-V, 3-Ph, 50-Cyclo (5-P!)1Meter Amazon eBay
304412515,000-Ohm, 25-W - For 220/380-V, 3-Phase, 4-Wire1Resistor Amazon eBay
304A15S Washer, Fixed Resistor Cent. to Alternator End Bell1Washer Amazon eBay
304PA76Resistor, Volt. Cont.Reactor (Incl.in Rect.& Resistor A: 305P218)1Resistor Amazon eBay
3058227Resistor Assy., Rect, & Incl. (Incl.in Rect. & Resistor A: 305P218)4Resistor Amazon eBay
305P233Rectifier Only, Power (Field) - Lower two - Negative (Begin Spec 'C' included in Rectifier & Reactor Assembly #305B227)2Rectifier Amazon eBay
305P234Rectifier Assy., Power (Field) (Incl. in Rect. #305P218)2Rectifier Amazon eBay
305P240Rectifier, Volt. Cont.Reactor (Incl.in Rect. & Resistor A: 305P218)4Rectifier Amazon eBay
309-0269Sender, Temperature-Lo Engine1Sensor Amazon eBay $239.00
309-0576Switch, Thermostat - High Engine Coolant Temperature (S2)1Sensor Amazon eBay
309-0641-03Switch, Low Oil Pressure (S110)1Sensor Amazon eBay
309-0641-07Switch, Oil Pressure (Closes at 20 lbs. Descending)1Sensor Amazon eBay
319-2236Bracket, Mounting1Bracket Amazon eBay
3320645Strip, Marker - Volt. Con. Reactor (9305P218)1Strip Amazon eBay
3ISA78Rectifier, Voltage Control1Rectifier Amazon eBay
502-0827Fitting, Hose – Barbed (1/2” ID Pipe to 3/4” ID Hose)2Hose Amazon eBay
503-0189Clamp, Hose1Hose Amazon eBay
503-1634-01Hose, Rubber (3/4” ID x 4”)4Hose Amazon eBay
508-0292Washer, Sealing - Copper1Seal Amazon eBay
511-0092Belt, Alternator1Belt Amazon eBay $13.97 NAPA $23.51
518-0548-58Clamp, Hose3Clamp Amazon eBay
5208190Stud, Fixed Resistor Mtg.1Stud Amazon eBay
805-35Bolt, Place - Generator Mtg. Support to End Bell4Bolt Amazon eBay
960-0504PCC Control Service Manual*Service manual Amazon eBay
960-0507Detector Control Service Manual**Service manual Amazon eBay $49.00
A9562-12 VOLT BATTERIES2Battery Amazon eBay
B-342-3sPRIMING TURBOCHARGER OIL SUPPLY INLET LINE. DISCONNECT AT THIS POINT TO PRIMETurbocharger Amazon eBay
CS-1382cINLET AIR DAMPERAir filter Amazon Amazon eBay eBay
ES-1214-2FLOAT SWITCHAir filter Amazon eBay
FS1803sFUEL FILTERSFuel filter Amazon eBay
102-1335Plug, Oil Drain1Service part / kit Amazon eBay
130-3588Cap, Radiator1Service part / kit Amazon eBay $79.00
130-4355Radiator (2 Row Core) DFBJ1Service part / kit Amazon eBay
130-4355-01Radiator (3 Row Core) DFCF, DFCG1Service part / kit Amazon eBay
130-4369Radiator DFCH1Service part / kit Amazon eBay
155-2409-01Elbow, Exhaust (5" OD With Threads)1Service part / kit Amazon eBay
191-1981Genset component (SJB series)1Service part / kit Amazon eBay
191-2121Regulator, Voltage1Service part / kit Amazon eBay
232A1489Generator support shim, 0.598 in gauge #6, 3x32Service part / kit Amazon eBay
232A1490Generator support shim, 0.359 in gauge #20, 3x32Service part / kit Amazon eBay
301021151Box Only, control1Service part / kit Amazon eBay
30118301Bracket, Cont.Box Mtg. (Repl. 2-Piece Brkts)1Service part / kit Amazon eBay
301A1914Bracket, Panel Stop1Service part / kit Amazon eBay
301A2727Handle , Control Box1Service part / kit Amazon eBay
302-21360-Cycle1Service part / kit Amazon eBay
302-234.Cycle1Service part / kit Amazon eBay
3028448Plate, Mater Face1Service part / kit Amazon eBay $74.95
302P411~~ Scale Reads 0-200 (1-Phase Use 2)1Service part / kit Amazon eBay
302P412Scale Reads 0-2501Service part / kit Amazon eBay
302P414Amm, Scale Reads 0-300 - Replaces 302-14.1Service part / kit Amazon eBay
302P415Ammeter Scale Reads 0-500 - Replaces 302-371.1Service part / kit Amazon eBay
302P422Scale Reads 0-6001Service part / kit Amazon eBay
302P423Scale Reads 0-750 on side of Gen1Service part / kit Amazon eBay
302P467For 277/480 Volt,3 Phase, 60 Cycle Plants.1Service part / kit Amazon eBay
303-111Rheostat, Volt. Reg. - 175-Ohm, (Model H)1Service part / kit Amazon eBay
303-32Knob, Rheos1Service part / kit Amazon eBay
304030545, 000-Ohm, 10-W - For 480-V , 3-Ph, 3-Wire & 277/480-V, 3+ Ph.1Service part / kit Amazon eBay
307-2621-02Relay, Start Solenoid (K4)1Service part / kit Amazon eBay
308-22Switch, Volt. & Current Selector Ammeter1Service part / kit Amazon eBay FridayParts $47.99
320823-Phase Models1Service part / kit Amazon eBay
320B18Single Phase Models1Service part / kit Amazon eBay
333-0639-01Heater, Coolant (4990 Watt)1Service part / kit Amazon eBay
333-0639-02Heater, Coolant (6420 Watt)1Service part / kit Amazon eBay
337A44Strap, Ground1Service part / kit Amazon eBay
402-78Rubber, Mtg. - Cont. Box4Service part / kit Amazon eBay
503-1575Clamp, V-Band1Service part / kit Amazon eBay
504-0011Valve, Shutoff (1/2”)1Service part / kit Amazon eBay $59.95
505-0019Bushing, Pipe - Reducer 1/2” to 3/8”, DFBF (1/2” to 3/8”) 505-0131 DFCB, DFCC, DFCE (3/4” to 3/8”)1Service part / kit Amazon eBay
505-0100Nipple, Pipe - Close (1/2”)1Service part / kit Amazon eBay $9.34
526-0029*Washer, Flat (1/2")1Service part / kit Amazon eBay
526-0219Washer, Flat (1/2)2Service part / kit Amazon eBay
800-0048Screw, Cap - Hex Head (3/8-16 x 3/4”)1Service part / kit Amazon eBay
800-0092Screw, Cap - Hex Head (1/2-13 x 1.5)4Service part / kit Amazon eBay
850-0050Washer, Lock - Spring (3/8”)2Service part / kit Amazon eBay
870-0212Nut, Locking (1/4-20)2Service part / kit Amazon eBay
EXS-1046sCONDENSATION TRAPService part / kit Amazon Amazon eBay eBay
FS1692sFUEL SOLENOID VALVE LOCATIONService part / kit Amazon eBay
M-1808DC CONTROL WIRINGService part / kit Amazon Amazon eBay eBay

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Standby100%77.320.4

Available documents

Spec sheet — Cummins-DFBF-spec-sheet (Onan)Spec sheet — Cummins-installation-manual-DFAA-DFAB-DFAC-DFBC-DFBF-DFBD-DFBE-DFBF-DFCB-DFCC-DFCE-DFEB-DFEC-DFED-DFFA-DFFB-DFGA-DFGB-DFGC-DFJA-DFJB-DFJC-DFJD-DFLA-DFLB-DFLC-DFLD-DFLE-DFMB-DQAA-DQAB-DQBA-DQBB (Cummins/Onan)Operator's manual — 960-0101C Cummins DFBF DFCB DFCC DFCE DQBA DQBB Operators Manual (3-2001) (Cummins/Onan)Operator's manual — 960-0138 Cummins DFBF DFCB DFCC Operator's Manual (1-2003) (Cummins/Onan)Operator's manual — 960-0176 Cummins DFBF DFCB DFCC DFCE Operator's Manual (2-2004) (Cummins/Onan)Parts manual — 0932-0112 Onan Post-Sale Literature Index (07-1998) (Cummins/Onan)Parts manual — 0960-0204 (Cummins/Onan)Parts manual — 0960-0219 I5 201402 (Cummins/Onan)Parts manual — 0960-0276 (Cummins/Onan)Parts manual — 0960-0294 I1 201712 (Cummins/Onan)Parts manual — 960-0276 Onan DFBF DFCB DFCC DFC# Parts Manual (10-1999) (Cummins/Onan)Service manual — 9-3Service manual — 960-0173 Cummins DFBF DFCB DFCC DFCE Operator's Manual (2-2004) (Cummins/Onan)Service manual — 960-0504 Onan DFxx series Generator Control Service Manual 04-1993 (Cummins/Onan)Service manual — 960-0507C Cummins DFAA thru DFMB DQAA Service Manual (2-2004) (Cummins/Onan)Service manual — 960-0519C Cummins DFAB DFB DFC DFG DFLC Series Service Manual (2-2004) (Cummins/Onan)Service manual — 960-0619D Cummins DFA DFB DFC DFE DFF DFG DFJ DFL DFM DQA DQB Installation (6-2003) (Cummins/Onan)Service manual — 960-0631B Cummins DFAB DFAC DFBF DFCC DFCE Installation Manual (2-2004) (Cummins/Onan)Service manual — 960-0634C Cummins DFAB DFBF DFCB DFCC DFCE Installation Manual (2-2004) (Cummins/Onan)Service manual — Cummins-3100-PowerCommand-DFAA-DFAB-DFAC-DFBC-DFBD-DFBE-DFBF-DFCB-DFCC-DFCE-DFEB-DFEC-DFED-DFFA-DFFB-DFGA-DFGB-DFGC-DFJA-DFJB-DFJC-DFJD-DFLA-DFLB-DFLC-DFLD-DFLE-DFMB-DQAA-DQAB-DQBB (Cummins/Onan)Service manual — DFxx Generator Set Service Manual PCC3100 (Cummins/Onan)Service manual — Detector Control Generator Set Service Manual (Cummins/Onan)

This page was generated from the 22 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Oil filter 123457$17.99
Belt 123461$18.95
2 priced items$36.94