Home›Generac›Generac MDG150

Generac MDG150 Generator Set

The Generac MDG150 is a 144 kW (180 kVA) Diesel standby generator set powered by a John Deere 6068HFG05 / 6068HFG06 engine. It is available at 120/240 V, 120/208 V and 277/480 V, single-phase, 60 Hz and rated 473 A. It holds about 32.5 L (8.6 gal) of oil and 42 L (11.1 gal) of coolant, with a maximum ambient rating of 10000 °C. Starting uses 1 group-1 battery rated 1000 CCA at 12 V. The set measures 3700×1524×2133 mm (145.7×60.0×84.0 in), weighs about 2820 kg (6217 lb) and produces 75 dBA at 7 m. An integrated tank holds 1355 L (358.0 gal), roughly 39 hours of runtime.

144 kW
Standby
32.5 L
Oil capacity
3
Document types

How to read your Generac serial & model number →

Typical fuel consumption for 140–145 kW Diesel generators →

Compare with other 140–145 kW Diesel generators →

Service parts for the MDG150

Grouped by system, with how many of each the parts manual calls for.

Fuel system

1 required

Prices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power144 kW
Standby kVA180
Prime power120 kW
Emissions4
ControllerElectronics DSE7310 MKII, Power Zone
Oil capacity32.5 L
AlternatorMarathon 363CSL1607 / 431CSL6202 / 431CSL6206
Voltage options120/208 V, 277/480 V, 120/240 V
PhaseSingle Phase,Three Phase
Rated current473 A
Power factor0.8
Circuit breaker600 A
Battery group1,000 CCA
Battery cranking1000 CCA
Battery voltage12 V
Battery quantity1
Coolant capacity42 L
Max ambient10000 °C
Dimensions (L×W×H)3700×1524×2133 mm
Dry weight2820 kg
Sound level75.0 dBA @ 7 m
Fuel tank1355.0 L
Tank runtime39 hr

Engine

John Deere 6068HFG05 / 6068HFG06
Oil capacity32.5 L
Coolant capacity63.2 L
Rated speed1800 rpm

Filters for the John Deere 6068HFG05 / 6068HFG06

6

Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.

SystemFilterDescriptionCross-references
Oil filterP550779Lube Filter, Spin-On Full FlowJOHN DEERE RE504836, JOHN DEERE RE50486, NAPA 7750S, SKYJACK 13502869 KuduParts $19.00
Oil filterP551352Lube Filter, Spin-On Full FlowJOHN DEERE DZ118286, JOHN DEERE PMLF3703, NAPA 401062, BALDWIN B40168 buy
Fuel filterP550090Fuel Filter, In-LineJOHN DEERE AE20952, JOHN DEERE AT101565, ASV INCORPORATED 0201914, LOESING 025125 FridayParts $45.66
Fuel filterP551130Fuel Filter, BoxJOHN DEERE AR50041, JOHN DEERE R16951, NAPA 3370, BALDWIN BF909 KuduParts $37.00
Fuel / water separatorP551424Fuel Filter, Water Separator Spin-OnJOHN DEERE RE503198, JOHN DEERE RE522868, NAPA 3532, NAPA 600094 KuduParts $16.00 FridayParts $18.50
Fuel / water separatorP551422Fuel Filter, Water Separator CartridgeJOHN DEERE AT274723, JOHN DEERE RE22878, NAPA 3978, CLAAS 0011318200 KuduParts $22.00 FridayParts $24.50

Maintenance & consumables

for the John Deere 6068HFG05 / 6068HFG06
ItemSpecCapacityPart #Interval
Air filterPaper Element Air Filter—
Fuel filter0H48930267 Amazon eBay NAPA $37.30
Fuel filterFuel Filtering (microns)—
Oil filterSpin-on Cartridge—500 hr
BatteryWet Cell Battery—
BeltVariable Speed Fan—
CoolantCooling System Capacity – gal (L)63.2 L—
Coolant filter—4500 hr
OilCrankcase Capacity – qts (L)34.3 L—500 hr
Spark plug—

Compatible filters for the John Deere 6068HFG05 / 6068HFG06 — cross-referenced via Donaldson. Options to verify against your serial number, not confirmed for this exact unit.

  • Air filter: John Deere AR79680 John Deere 4S00686R John Deere AH115833 John Deere RE181915 John Deere F434389J
  • Oil filter: John Deere RE519987 John Deere RE555072 John Deere DZ118286 John Deere AR58956 John Deere TCA10018

Service intervals

22
ItemActionHoursMonthsNotes
maintenance alarm resetOther250 hrMaintenance/service interval warning set at 250, 500 and 3,000 hours of engine running time
Automatic belt tensioner and belt wearCheck500 hr12 moRecommended that the belt be removed and checked for wear at the 500 hour or 12 month service interval
Engine oil and oil filterChange500 hr12 moFirst service — Change oil and filter between 100–500 hours during initial operation of new or rebuilt engine with Break-In Plus; if not using John Deere Plus 50 II, decrease interval to every 250 hours
coolant pump weep holeCheck500 hr12 mo
cooling systemCheck1500 hr12 mo
fuel filter elementsReplace500 hr12 mo
open crankcase vent (OCV) systemCheck500 hr12 mo
Cooling systemTest2000 hr24 moPressure test cooling system
Engine speedsCheck2000 hr24 mo
Crankshaft vibration damperCheck3000 hr36 mo
DEF dosing unit filterChange3000 hr36 mo
Engine electrical ground connectionCheck3000 hr36 mo
Engine mountsCheck3000 hr36 mo
Engine valve clearanceAdjust3000 hr36 mo
Glow plugsTest3000 hr36 moTest glow plugs for continuity
Cooling systemChange4500 hr60 moFlush and refill cooling system
Crankshaft vibration damperChange4500 hr36 mo
ThermostatsTest4500 hr60 mo
Axles and jacksLubricate12 moGrease axles and jacks (annually)
Wheel bearingsInspect12 moOr every 12,000 miles (19,312 km); more frequent under dusty or damp conditions
jacksLubricate12 moJack maintenance procedures should be performed annually (side-wind and top-wind models)
trailer wheel bearingsLubricate12 moMinimum recommended lubrication every 12 months or 12,000 miles (19,312 km); more frequent in dusty or damp conditions

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Service specifications

40
TypeItemValueUnitCondition
OtherAir filter restriction (replace point)20in. H2OWhen yellow center bar reaches red section on filter minder gauge
OtherAir filter restriction indicator - replace air filter20in. H2Oyellow center bar reaches red section
OtherAltitude for full prime/standby power10,000ft (3,048 m)5% power loss per 1,000 ft above maximum altitude
OtherDEF urea concentration31.8-33.2% urea
OtherDEF urea concentration31.8–33.2% urea
PressureAir filter replacement threshold (filter minder)20in. H2Oyellow center bar reaches red section
PressureEngine oil pressure - normal operating35-80psi (241-552 kPa)engine running
PressureLow oil pressure shutdown - verify pressure reached within five seconds of restart5psi (34.5 kPa)within five seconds
PressureMaximum tire pressure125psi (862 kPa)
PressureMinimum oil pressure at start5psi (34.5 kPa)Within five seconds of start
PressureOil pressure5psi (34.5 kPa)within five seconds of restart
PressureOil pressure gauge range0-100psi (0-689 kPa)
SpeedEngine governed operating speed1800RPMconstant
SpeedEngine idle speed1,000 to 1,200rpmidle
SpeedEngine idle speed1,000-1,200rpm
SpeedEngine operating speed1,800rpm
SpeedOperating speed (governed)1800rpm
SpeedOutput frequency60HzNo load connected
SpeedOutput frequency - normal operating60Hzno loads connected
TemperatureAdditional cold weather starting aids required below-13°F (-25 °C)
TemperatureCold weather starting aids required below32°F (0 °C)
TemperatureCoolant temperature gauge range150-250°F (66-121 °C)
TemperatureCoolant temperature shutdown threshold210°F (99 °C)
TemperatureDEF freezing point12°F (-11 °C)
TemperatureEngine coolant temperature - normal operating180-200°F (82-93 °C)average ambient air temperature of 70 °F (21 °C)
TemperatureEngine coolant temperature - stop engine210°F (99 °C)or higher
TemperatureHigh coolant temperature - stop engine immediately210°F (99 °C)or higher
TemperatureMaximum air temperature for full prime power42°Cstandby power
TemperatureMaximum air temperature for full prime power (standby)49°CMDG150/MDG175 standby; MDG250 prime
TemperatureMaximum allowable coolant temperature235°F (113 °C)
TorqueGenerator drive plate bolts40ft-lbs (54 Nm)
TorqueGenerator drive plate bolts44ft-lb (56.9 Nm)
TorqueWheel lug nuts - first pass20-25ft-lb (27-33 Nm)First pass tightening
TorqueWheel lug nuts - first pass20–25ft-lb (27–33 Nm)
TorqueWheel lug nuts - second pass50-60ft-lb (67-81 Nm)Second pass tightening
TorqueWheel lug nuts - second pass50–60ft-lb (67–81 Nm)
TorqueWheel lug nuts - third pass90-120ft-lb (122-162 Nm)Third pass tightening
TorqueWheel lug nuts - third pass90–120ft-lb (122–162 Nm)
VoltageBattery voltage - normal reading (12 volt systems)12-14Vengine running
VoltageFine voltage adjustment range±10%

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Recommended fluids

FluidGradeStandardAmbientCapacityNotes
Coolant50/50, 40/60, 40/60, 40/60 water/antifreeze mixabove -67°C63.2 LFreezing point table: 50% water/50% antifreeze = -12 °F (-24 °C); 40%/60% = -34 °F (-36 °C); 40%/60% = -54 °F (-48 °C); 40%/60% (maximum freeze protection at 60%) = -90 °F (-67 °C). Do not use chromate base rust inhibitor with propylene glycol base antifreeze, boosters, or additives.
Coolant50% water / 50% antifreeze (down to -12 °F / -24 °C); 40% water / 60% antifreeze (to -34 °F / -36 °C and -48 °F / -48 °C, -90 °F / -67 °C); maximum freeze protection 60%above -24°C63.2 LCoolant including engine 16.7 gal (63.2 L). Do not use chromate base rust inhibitor with propylene glycol base antifreeze, boosters, or additives.
DefAqueous Urea Solution 32 (AUS 32)ISO 22241-1-11°C to 30°C130.4 LDEF freezes below 12 °F (-11 °C); quality degrades rapidly above 140 °F (60 °C). Ideal storage 23–86 °F (-5–30 °C). Urea concentration must remain between 31.8–33.2%. John Deere DEF recommended; API or AdBlue certified DEF acceptable. DEF Tank Volume 34.4 gal (130.4 L); usable 28 gal (106 L).
DefAqueous Urea Solution 32 (AUS 32); 31.8–33.2% ureaISO 22241-1; API Diesel Exhaust Fluid Certification Program or AdBlue Diesel Exhaust Fluid Certification-11°C to 30°C130.4 LDEF tank total 34.4 gal (130.4 L), usable 28 gal (106 L). Unit does not ship from factory with DEF in tank. DEF freezes below 12 °F (-11 °C); degrades rapidly above 140 °F (60 °C); ideal storage 23–86 °F (-5–30 °C). John Deere DEF recommended.
DefAqueous Urea Solution 32 (AUS 32) - John Deere DEF recommendedISO 22241-1-5°C to 30°C34.4 galDEF tank total 34.4 gal (130.4 L); usable 28 gal (106 L). Urea concentration must remain 31.8-33.2%. Degrades above 140 °F (60 °C); freezes below 12 °F (-11 °C). Ideal storage 23-86 °F (-5-30 °C). Use API or AdBlue certified DEF if John Deere DEF unavailable.
Engine oilJohn Deere Plus-50 II or John Deere Plus-50 (extended 500 hr interval); John Deere Torq-Gard Supreme, API CJ-4, API CI-4 PLUS, API CI-4, API CH-4, ACEA E9, ACEA E7, ACEA E6, ACEA E5, ACEA E432.5 LOil capacity including filter 8.6 gal (32.5 L); 500 hour extended oil and filter change interval only with John Deere Plus-50 II/Plus-50 oil and approved John Deere oil filter. Factory filled with break-in oil.
Engine oilJohn Deere Plus-50 II, John Deere Plus-50, John Deere Torq-Gard SupremeAPI CJ-4, API CI-4 PLUS, API CI-4, API CH-4, ACEA E9, ACEA E7, ACEA E6, ACEA E5, ACEA E48.6 galOil including filter = 8.6 gal (32.5 L). 500 hour extended oil/filter change interval only with John Deere Plus-50 II or Plus-50 oil and an approved John Deere oil filter. Use high quality detergent oil with viscosity appropriate for ambient temperature.
Engine oilJohn Deere Plus-50, John Deere Plus-50 II, John Deere Torq-Gard Supreme, API CJ-4, API CI-4 PLUS, API CI-4, API CH-4, ACEA E9, ACEA E7, ACEA E6, ACEA E5, ACEA E432.5 LOil (including filter) capacity 8.6 gal (32.5 L). 500 hour extended drain interval only with extended drain oil pan, diesel sulfur content less than 2000 mg/kg, John Deere Plus-50 II or Plus-50 oil and approved John Deere oil filter. Factory filled with break-in oil.
FuelUltra Low Sulfur Diesel358.0 galStandard fuel tank total 358 gal (1,355 L); usable 343 gal (1,297 L). Optional fuel tank total 529 gal (2,002 L); usable 513 gal (1,914 L).
GreaseHigh quality grease made specifically for lubrication of wheel bearings; automotive grease for jack internal gearingLubricate wheel bearings every 12 months or 12,000 miles (19,312 km); jack maintenance annually

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Procedures

12
Changing DVR2400 Voltage Regulator Settings adjustment

⚠ Modifications of parameter values are immediately effective.

  1. Repeatedly press SELECT button until the desired parameter displays.
  2. Press ENTER; EDIT mode activates and current value displays.
  3. Press UP and DOWN buttons to modify the value.
  4. Press ENTER to save; value flashes three times to confirm.
Fine Voltage Adjustment adjustment
  1. With the unit running, press the Voltage Adjust button.
  2. Press ENTER. The voltages displayed will flash.
  3. Use UP and DOWN arrows to adjust the voltage.
  4. Press ENTER to confirm; the voltages stop flashing.
Checking Generator Drive Plate Torque maintenance

Tools: Torque wrench

  1. Disconnect battery.
  2. Remove generator fan guard.
  3. Tighten each of the drive plate bolts to 44 ft-lb (56.9 Nm).
  4. Install generator fan guard.
  5. Connect battery.
Cleaning DEF Tank maintenance

Tools: Suitable container, Distilled water

  1. Drain DEF tank into a suitable container.
  2. Flush DEF tank with distilled water.
  3. Fill with new or good DEF.
DEF Tank Cleaning maintenance
  1. Drain DEF tank into a suitable container.
  2. Flush DEF tank with distilled water, and fill with new or good DEF.
Jack Maintenance maintenance

⚠ Perform annually.

Tools: Grease gun, Needle-nose applicator

  1. Side-wind: apply automotive grease to internal gearing via jack cover, needle-nose applicator, or grease gun; rotate handle to distribute.
  2. Side-wind: apply lightweight oil to handle at both sides of the tube.
  3. Side-wind: lubricate caster wheel axle bolt and nut if equipped.
  4. Top-wind: apply lightweight oil to the screw stem.
Jack Maintenance (Side-Wind Models) maintenance

Tools: Grease gun, Needle nose applicator

  1. Apply a small amount of automotive grease to the internal gearing.
  2. Rotate the jack handle to distribute the grease evenly.
  3. Apply lightweight oil to the handle unit at both sides of the tube.
  4. If equipped, lubricate the caster wheel axle bolt and nut assembly with the same lightweight oil.
Refilling DEF Tank maintenance

⚠ Risk of poisoning. Do not ingest diesel exhaust fluid.

⚠ Immediately clean any surfaces with water that come in contact with diesel exhaust fluid.

⚠ If DEF is filled into engine fuel tank, do not operate engine until system is purged.

Tools: Lint free cloth, Polyethylene, polypropylene, or stainless steel containers

  1. Verify DEF tank cap area is free of debris before removing cap.
  2. Wipe clean with a lint free cloth.
  3. Seal DEF containers between use to prevent contamination and evaporation.
  4. Avoid splashing DEF and contact with skin, eyes, or mouth.
  5. Check DEF level daily and refill tank as needed; fill port has blue cap with DEF symbol.
Resetting Maintenance Alarms maintenance
  1. With unit shut down, move control power switch to CONTROL ON (I).
  2. Press ▲, ►, ▼, or ◄ to enter the maintenance screens.
  3. Press and O simultaneously to display the Configuration menu.
  4. Press to move the cursor down to the maintenance group.
  5. Press ► to access sections; press to highlight the maintenance section.
  6. Press ► to access parameters and highlight the maintenance alarm to reset.
  7. Press to select editable parameters; press to highlight RESET.
  8. Press to reset the selected maintenance alarm.
  9. Repeat steps 6–8 for additional alarms.
  10. Press and hold for five seconds to save changes; press and hold O for five seconds to discard.
Resetting the Maintenance Alarms maintenance
  1. With unit shut down, move control power switch to CONTROL ON (I).
  2. Press a navigation button to enter the maintenance screens.
  3. Press enter and O simultaneously to display the Configuration menu.
  4. Move cursor down to the maintenance group.
  5. Press right arrow to access sections; highlight the maintenance section.
  6. Press right arrow to access parameters; highlight the alarm to reset.
  7. Press enter to select editable parameters; highlight RESET and press enter.
  8. Press and hold enter for five seconds to save changes.
Testing DEF maintenance

⚠ Do not create DEF by mixing agricultural grade urea with water.

Tools: JDG11594 Digital DEF Refractometer, JDG11684 DEF Refractometer

  1. Draw a DEF sample into a clear container; DEF must be crystal clear.
  2. If cloudy or tinted, drain tank, flush with distilled water, and fill with new DEF.
  3. If visual and smell tests pass, check concentration with a handheld refractometer.
  4. If concentration is not within specification, drain, flush with distilled water, and refill.
Trailer Wheel Bearings maintenance

⚠ More frequent lubrication may be required under extremely dusty or damp conditions.

Tools: Standard grease gun, Clean cloth, High quality wheel bearing grease

  1. Remove the small rubber plug on the grease cap.
  2. Attach a standard grease gun fitting to the grease fitting.
  3. Pump grease into the fitting until new grease is visible around the nozzle.
  4. Wipe excess grease from the hub with a clean cloth and replace the rubber plug.

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Voltage reconnection

VoltagePhaseConnectionLeadsNotes
3Cam lock panel / terminal lugsL1 Black, L2 Red, L3 Blue, N White, G GreenNEUTRAL (L0) BONDED TO FRAME from factory; bonding plate must be removed when used as standby power source
120/2083120/208V 3-phase (Low Wye)L1, L2, L3, NL1-L2 = 208V, L2-L3 = 208V, L3-L1 = 208V; L1-N = 120V, L2-N = 120V, L3-N = 120V
120/208V3Low wye (120/208V 3-phase)T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12L1-L2 = 208V; L1-N = 120V; L2-L3 = 208V; L2-N = 120V; L3-L1 = 208V; L3-N = 120V
120/208V3Low wye / Zig zagT1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12, NL1-L2 = 208V, L2-L3 = 208V, L3-L1 = 208V; L1-N = 120V, L2-N = 120V, L3-N = 120V.
120/2401120/240V 1-phase (Zig Zag)L1, L3, NL1-L3 = 240V; L1-N = 120V; L2-N = -------; L3-N = 120V
120/2403120/240V 3-phase (optional 4th position on voltage selector switch)L1, L2, L3, NL1-L2 = 240V, L2-L3 = 240V, L3-L1 = 240V; L1-N = 120V, L2-N = 208V, L3-N = 120V
120/240V1Single phaseT1, T2, T4, T5, T6, T8, T10, T11, T12, NL1-L2 = 240V; L1-N = 120V.
120/240V1Zig zag (120/240V 1-phase)T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12L1-L3 = 240V; L1-N = 120V; L2-N = -------; L3-N = 120V
120/240V3Delta (120/240V 3-phase, 4-position switch only)T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12L1-L2 = 240V; L1-N = 120V; L2-L3 = 240V; L2-N = 208V; L3-L1 = 240V; L3-N = 120V
120/240V3Delta (4-position switch)T1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12, NL1-L2 = 240V, L1-N = 120V; L2-L3 = 240V, L2-N = 208V; L3-L1 = 240V, L3-N = 120V.
2083Voltage selector switch position labelNeutral (L0) bonded to frame when shipped from factory; bonding plate must be removed when used as standby power source
277/4803277/480V 3-phase (Hi Wye)L1, L2, L3, NL1-L2 = 480V, L2-L3 = 480V, L3-L1 = 480V; L1-N = 277V, L2-N = 277V, L3-N = 277V
277/480V3Hi wye (277/480V 3-phase)T1,T2,T3,T4,T5,T6,T7,T8,T9,T10,T11,T12L1-L2 = 480V; L1-N = 277V; L2-L3 = 480V; L2-N = 277V; L3-L1 = 480V; L3-N = 277V
277/480V3Hi wye / Delta (4-position)T1, T2, T3, T4, T5, T6, T7, T8, T9, T10, T11, T12, NL1-L2 = 480V, L2-L3 = 480V, L3-L1 = 480V; L1-N = 277V, L2-N = 277V, L3-N = 277V. Neutral bonded to frame.
4803Voltage selector switch position labelTerminal lead colors: L1 Black, L2 Red, L3 Blue, N (Neutral) White, G (Ground) Green

Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.

Common questions

What size generator is the Generac MDG150?

The Generac MDG150 is rated 144 kW standby (180.0 kVA).

Which engine powers the Generac MDG150?

The Generac MDG150 is powered by the John Deere 6068HFG05 / 6068HFG06 engine.

What kind of fuel does the Generac MDG150 run on?

The Generac MDG150 runs on Diesel.

What is the oil capacity of the Generac MDG150?

The John Deere 6068HFG05 / 6068HFG06 engine in the Generac MDG150 has an oil capacity of 32.5 liters.

What is the coolant capacity of the Generac MDG150?

The Generac MDG150 cooling system holds 42 liters (11.1 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.

What is the prime power rating of the Generac MDG150?

The Generac MDG150 is rated 120 kW prime (150 kVA), against 144 kW standby.

What is the sound level of the Generac MDG150?

The Generac MDG150 is rated at 75.0 dBA at 7 m, per the manufacturer specification sheet.

How much does the Generac MDG150 weigh?

The Generac MDG150 has a dry weight of 2820 kg (6217 lb).

How big is the fuel tank on the Generac MDG150?

The Generac MDG150 has a 1355 liter (358 US gallon) fuel tank, giving about 39 hours of runtime.

What voltages is the Generac MDG150 available in?

The Generac MDG150 is offered in 120/208 V, 277/480 V, 120/240 V, Single Phase,Three Phase-phase.

How many cold cranking amps does the Generac MDG150 require?

The Generac MDG150 uses 1 battery, 12 V each, 1000 CCA, group 1,000 CCA, per the manufacturer specification sheet.

What alternator does the Generac MDG150 use?

The Generac MDG150 uses a Marathon 363CSL1607 / 431CSL6202 / 431CSL6206 alternator.

What oil filter fits the Generac MDG150?

The Generac MDG150 uses oil filter part numbers JOHN DEERE RE519987, JOHN DEERE RE555072.

What fuel filter fits the Generac MDG150?

The Generac MDG150 uses fuel filter part number 0H48930267.

Which air filter part number does the Generac MDG150 take?

The Generac MDG150 uses air filter part numbers JOHN DEERE AR79680, JOHN DEERE 4S00686R.

Troubleshooting

6

Fault codes

CodeMeaning
FXXXIndicates a fault state. The DVR stops providing excitation.

Symptoms & remedies

SymptomCauseRemedy
Low Load indicator LED is illuminated.Resolve by increasing electrical load. If unable to operate genset at more than 30% load, use a smaller generator.
Lug Door Open indicator LED is illuminated.Resolve by closing lug-box door. If condition remains unresolved, inspect lug-box door safety switch for proper operation.
Emergency Stop indicator LED is illuminated.Resolve by deactivating (pulling out) Emergency Stop switch.
Shutdown indicator LED is illuminated.Resolve by resolving shutdown condition.
AXXX indicates an alarm state. The DVR continues to provide excitation, if excitation is enabled.[blank] Indicates normal operation in SLEEP mode. STBY Indicates normal operation in stand-by mode, waiting for the STRT state. STRT Indicates DVR is in a soft start state. RUN.V Indicates normal operation, with excitation in AVR mode. RUN.I Indicates normal operation, with excitation in FCR mode. RUN.P Indicates normal operation, with excitation in VAR or PF mode. FLSH Indicates DVR is in field flashing mode. IDLE Indicates normal operation in idle state, waiting for the speed to take off.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

10
Part #DescriptionQtySystem
011064Cold Weather OperationCold weather operation Amazon eBay
10000037182Clamp, hose - spring type CTB-27ST6Hose Amazon eBay
50332Hose, fuel .750 ID 35 PSI SAE 30R71Hose Amazon eBay
60316Clamp, hose - SAE 032 (1.56-2.50)4Hose Amazon eBay
011068Status: Generator at Rest, Stop Mode, 22:31Service part / kit Amazon eBay
011136DANGER Electrocution. Do not disable or modify the connection box door safety switch.Service part / kit Amazon eBay
51551Decal set, safety1Service part / kit Amazon eBay $47.44
51552Decal, high temp1Service part / kit Amazon eBay
54005CAP, DEF FILL1Service part / kit Amazon eBay
55104CAP, FUEL FILL 3.50 - GREEN1Service part / kit Amazon eBay $6.25

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime33.08.7
Prime25%12.93.4
Prime50%19.85.25
Prime75%26.87.1
Prime100%33.38.7
Prime110%35.969.5
Standby25%13.63.6
Standby50%22.05.8
Standby75%29.57.8
Standby100%36.09.5

Available documents

Spec sheet — mdg150df4-diesel-generator ss (Generac)Owner's manual — A0000393893 (Generac)Owner's manual — Generac Towable MDG150-175-250DF4 Operators Manual (Generac)Owner's manual — mdg150-mdg175-mdg250 owners-manual (Generac)Parts manual — 10000016959 (Generac)Parts manual — MDG150DF4-Spec-Sheet 1 Generac Mobile (Generac)

This page was generated from the 6 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.

Full service, cheapest listings

Priced items from this model's own parts manual.

Fuel filter 0H48930267$37.30
1 priced item$37.30
Other sets with this engine