| | Grounding/bonding | Bonding conductor; No. 8 AWG copper wire minimum | Ground generator by solid mounting to vehicle frame/chassis or by approved bonding conductor. DO NOT disconnect bonding conductor. If replaced, use only flexible No. 8 AWG copper wire minimum. |
| | Isolation of power sources | Junction box to double-pole, double-throw transfer switch or approved isolation receptacle | Must prevent vehicle electrical circuits from being connected to two different power supplies at the same time (generator and dockside power). Generator AC connection system uses a GROUNDED neutral; a separate green ground wire connects to the vehicle junction box. |
| 120 | 1 | 120 V only - dual stator windings connected in parallel | T1 (red) and T3 (black) hot; T2 (white) grounded neutral; green ground wire | Line T1 to T2 protected by 30-amp circuit breaker CB1; line T3 to T2 protected by 30-amp circuit breaker CB2. Maximum current 58.3 A (70G) or 55.0 A (70LP) at 120 V. |
| 120 | 1 | 120 VAC loads only | T1(Red)-T2(White) or T3(Black)-T2(White) | Grounded neutral, dual stator AC power windings |
| 120 | 1 | Connection for 120 Volts Only (Figure 1) | Dual stator power windings; grounded neutral; CB1 | These air-cooled Q Series generator sets are equipped with dual stator AC power windings supplying power by a dual 2-wire connection system. |
| 120 | 1 | Dual 2-wire connection system | T1, T2, T3, T4; BLACK, WHITE, GROUNDED NEUTRAL | Connection for 120 volts only (Figure 1) |
| 120 | 1 | Dual 2-wire connection system (120 volts only) | Dual stator power windings; grounded neutral | Figure 1 — Connection for 120 Volts Only; jumper between circuit breakers must be removed when connecting for 120/240 volts |
| 120 | 1 | Loads across T1 (red) to T2 (white) and T3 (black) to T2 (white) | T1 (red), T2 (white), T3 (black) | Must not exceed 58.3 amps for PRIMEPACT 70G or 55 amps for PRIMEPACT 70LP with 120 V across each set of terminals. Do NOT connect loads in excess of circuit breaker ratings. |
| 120 | single | 120 VAC loads only | T1 (red) and T3 (black) hot, T2 (white) grounded neutral | Max total wattage equal to generator's rated power output, 120V across output terminals |
| 120 | single | 120 volts only — dual 2-wire connection with jumper between circuit breakers installed | | Figure 1 connection for 120 volts only; grounded neutral |
| 120 volts only | 1 | jumper installed between circuit breakers | T1/T2/T3/T4, neutral | stator dual 2-wire connection system |
| 120 volts only | single | jumper wire installed between circuit breakers for 120/240V reconnection | T1/T2/T3/T4, grounded neutral | dual stator AC power windings, dual 2-wire connection system; neutral grounded |
| 120/240 | 1 | 120/240 VAC loads | T1(Red)-T2(White)-T3(Black) | One 240V load, or two 120V loads each up to half rated wattage |
| 120/240 | 1 | Dual voltage reconnection | | Remove jumper between circuit breakers when connecting for 120/240 volts. Units are not listed per RVIA/ANSI when reconnected for dual voltage output. |
| 120/240 | 1 | Reconnectable dual voltage output | Dual stator power windings | All units are reconnectable to 120 and/or 240 volts, dual voltage output; units are not listed per RVIA/ANSI when reconnected for dual voltage output |
| 120/240 | 1 | Reconnected for dual voltage AC output | Dual stator power windings | Be sure to remove the jumper between the circuit breakers when connecting for 120/240 volts. If reconnected for dual voltage, the unit is no longer RVIA listed. |
| 120/240 | single | 120/240 VAC loads | T1 (red), T2 (white), T3 (black); dual stator AC power windings | One load at 240V full rated output, or two separate 120V loads each up to half rated output; T1-T2 protected by 30A CB1, T3-T2 protected by 30A CB2 (20A CB2 on some models) |
| 120/240 | single | Dual voltage output — remove the jumper between the circuit breakers | | Units are not listed per RVIA/ANSI when reconnected for dual voltage output; replacement line breakers consist of two separate breakers with a connecting piece between handles |
| 230 | Single | Dual two-wire connection system, neutral grounded (Figure 1.1 — Connections for 230 Volts Only) | | Dual stator AC power windings; two 30-amp circuit breakers. If reconnected for dual voltage AC output (115/230 volts), replacement line breakers consist of two separate breakers with a connecting piece between the handles. |
| 230 | Single | Dual two-wire connection system; neutral is grounded; one side of the winding is grounded | T1 (red) 'hot', T3 (black), green ground wire | Dual stator AC power windings; solid-state voltage regulator connected across 1/2 of the output winding, regulating at 115 volts when AC frequency is 50 Hertz |
| 240 | 1 | 120/240 V dual voltage output | T1 (red), T2 (white), T3 (black), green ground wire | All units are reconnectable to 120 and/or 240 volts, dual voltage output. Units are not listed per RVIA/ANSI when reconnected for dual voltage output. Rated maximum continuous current at 240 volts is 29.2 amps (70G) or 27.5 amps (70LP). |