Cummins/Onan — Mount Components
Installation · EC-AGS+ Gateway and Temperature Sensor
From a Cummins/Onan owner's manual covering: LP 2500, LP 3600, LP 5500, LP 6500, QD 10000, QD 12500, QD 5000, QD 5500, QD 6000, QD 8000, QG 2800, QG 4000…. Check it applies to your exact model before use.
Applies to: Cummins/Onan HDKA, Cummins/Onan HDKB, Cummins/Onan HDKC, Cummins/Onan HGJAA, Cummins/Onan HGJAB, Cummins/Onan HGJAD, Cummins/Onan HGJAE, Cummins/Onan HGJBB, Cummins/Onan HGLAA
Before you start
- High ambient temperature can cause damage to the EC-AGS+ gateway.
Procedure
- Do not install the EC-AGS+ gateway directly inside the generator set compartment.
- Mount the EC-AGS+ gateway in a suitable, easily accessible location.
- Drill holes for the fastening screws and mount the EC-AGS+ gateway using mounting screws.
- Mount the temperature sensor(s) near an A/C thermostat (one per zone, 3 maximum).
- Drill 2 holes for screws and mount the sensor.
Specs & values
- EC-AGS+ gateway dimensions: 120 mm x 108 mm x 38 mm (4.72 in x 4.25 x 1.5 in)
- EC-AGS+ gateway temperature range: –40–70 °C (–40–158 °F)
- Temperature sensor dimensions: 51 mm x 70 mm x 17 mm (2 in x 2.76 x 0.67 in)
- Temperature sensor temperature range: –40–85 °C (–40–185 °F)
Full service-parts list: Cummins/Onan HDKA →, Cummins/Onan HDKB →, Cummins/Onan HDKC →, Cummins/Onan HGJAA →, Cummins/Onan HGJAB →, Cummins/Onan HGJAD →, Cummins/Onan HGJBB →, Cummins/Onan HGLAA →
Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.