Cummins/Onan — Installation and Setup Test

Testing & diagnosis · EC-AGS+ System

From a Cummins/Onan owner's manual covering: LP 2500, LP 3600, LP 5500, LP 6500, QD 10000, QD 12500, QD 5000, QD 5500, QD 6000, QD 8000, QG 2800, QG 4000…. Check it applies to your exact model before use.

Applies to: Cummins/Onan HDKA, Cummins/Onan HDKB, Cummins/Onan HDKC, Cummins/Onan HGJAA, Cummins/Onan HGJAB, Cummins/Onan HGJAD, Cummins/Onan HGJAE, Cummins/Onan HGJBB, Cummins/Onan HGLAA

Procedure

  1. Verify generator set operation using the Start/Stop switch located on the generator set.
  2. Verify manual start/stop of the generator set from the app dashboard using the START and PRIME/STOP buttons.
  3. Check operation of the temperature sensors with Auto mode and Air Conditioning Sense enabled.
  4. Verify the generator set starts automatically when the settings are met.
  5. Verify the accelerometer by driving the vehicle at 10 mph and checking that AGS is automatically disabled.
  6. Verify delayed shutdown: enable AGS, allow the generator set to start, disable AGS, confirm shutdown in 10 minutes.

Specs & values

  • Generator set shuts down in 10 minutes after AGS is disabled.

Full service-parts list: Cummins/Onan HDKA →, Cummins/Onan HDKB →, Cummins/Onan HDKC →, Cummins/Onan HGJAA →, Cummins/Onan HGJAB →, Cummins/Onan HGJAD →, Cummins/Onan HGJBB →, Cummins/Onan HGLAA →

Source: Cummins/Onan owner's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.