Home›Repair guides›Cummins/Onan›Fan Belt Replacement (QSG-Series)

Cummins/Onan — Fan Belt Replacement (QSG-Series)

Maintenance · Radiator cooling blower belt

From a Cummins/Onan service manual — check it applies to your exact model before use.

Applies to: Cummins/Onan DGBB, Cummins/Onan DGBC, Cummins/Onan DGCA, Cummins/Onan DGCB, Cummins/Onan DGDA, Cummins/Onan DGDB, Cummins/Onan DGEA, Cummins/Onan DGFA, Cummins/Onan DGFB, Cummins/Onan 4B3.9 engine

Before you start

  • Disconnect starting battery cables (negative cable first)
  • Disconnect battery charger from AC source first

Procedure

  1. Shut down the set and disconnect the batteries (negative cable first).
  2. Remove the air inlet screen and box from the front of the set.
  3. Remove the air cone.
  4. Loosen the four blower hub bolts and withdraw the blower and spacers.
  5. Slip the old belt off and the new belt on over the top pulley.
  6. Reassemble the blower, lining up the four matching bolt holes.
  7. Tighten all four hub bolts by hand, then torque each to 8 ft-lbs (11 Nm).
  8. Thread the fan belt through the pulleys per the engine service manual, then reassemble the air cone, screen and box.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Hub bolt torque 8 ft-lbs (11 Nm)

Full service-parts list: Cummins/Onan DGBB →, Cummins/Onan DGBC →, Cummins/Onan DGCA →, Cummins/Onan DGCB →, Cummins/Onan DGDA →, Cummins/Onan DGDB →, Cummins/Onan DGEA →, Cummins/Onan DGFA →, Cummins/Onan DGFB →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.