Cummins/Onan 3100 series — Disassembling the PMG

Repair & overhaul · Permanent Magnet Generator (PMG)

For the Cummins/Onan 3100 series, from the Cummins/Onan service manual.

Applies to: Cummins/Onan DGBB, Cummins/Onan DGBC, Cummins/Onan DGCA, Cummins/Onan DGCB, Cummins/Onan DGCC, Cummins/Onan DGDA, Cummins/Onan DGDB, Cummins/Onan DGDK, Cummins/Onan DGEA, Cummins/Onan DGFA, Cummins/Onan DGFC

Before you start

  • Accidental starting of the generator set while working on it can cause severe injury or death.
  • Always disconnect a battery charger from its AC source before disconnecting the battery cables.

Procedure

  1. Disconnect the starting battery cables (negative (-) first).
  2. Remove the PMG cover and disconnect the leads at the connector.
  3. Remove the bolts and clamps securing the PMG stator to the generator frame and carefully pull away the stator.
  4. Remove the rotor center bolt and pull away the rotor; the rotor is magnetic and will attract iron filings.
  5. Put the rotor in a clean plastic bag until remounted; do not take it apart or it will lose its magnetism.

Specs & values

  • Torque the rotor center bolt to 40 ft-lbs (54 Nm)
  • The stator leads must be at 12 o'clock

Full service-parts list: Cummins/Onan DGBB →, Cummins/Onan DGBC →, Cummins/Onan DGCA →, Cummins/Onan DGCB →, Cummins/Onan DGCC →, Cummins/Onan DGDA →, Cummins/Onan DGDB →, Cummins/Onan DGEA →, Cummins/Onan DGFA →, Cummins/Onan DGFC →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.