Specifications
| Fuel | Natural Gas or Propane Vapor |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 17 kW |
| Prime power | 17 kW |
| Controller | Alternator, Transfer Switch |
| Oil capacity | 2.3 L |
| Voltage options | 120/240 V |
| Phase | Single Phase |
| Battery group | 51 |
| Battery cranking | 450 CCA |
| Battery voltage | 12 V |
| Dimensions (L×W×H) | 865×915×694 mm |
| Dry weight | 241 kg |
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | — | 200 hr | |||
| Oil filter | — | 200 hr | |||
| Battery | Nominal 12 VDC; Battery Group 51 R; Lead Acid; Minimum Cold Crank Amps (CCA) 450 | — | 200 hr | ||
| Oil | Full synthetic gasoline engine oil meeting or exceeding API service SN/SN-RC and ILSAC GF-5; 5W30 above -17 °C (0 °F); 0W30 all temperatures, required below -17 °C (0 °F) | 2.3 L | — | 200 hr | |
| Spark plug | Gap 0.7 - 0.8 mm (0.027 - 0.031 in); Torque 25 - 30 Nm (18 - 22 ft-lb) cold engine | — |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Service intervals
6| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Engine Oil Level | Check | 24 hr | Also check daily during power outages, or monthly without power outages. | |
| Engine Oil and Oil Filter | Change | 200 hr | 24 mo | First service — First 25 hours. |
| Complete System Test | Test | 200 hr | 24 mo | Must be performed by a qualified service technician; see transfer switch manual. |
| Engine Air Filter | Replace | 200 hr | Perform more often in dusty conditions. | |
| Engine Valve Clearance | Adjust | 200 hr | 24 mo | Must be performed by a qualified service technician. |
| Starting Battery | Clean | 200 hr | Clean and check starting battery. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
60| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Minimum to combustible walls (front) | 915 | mm | installation |
| Clearance | Minimum to combustible walls (side) | 1524 | mm | installation |
| Clearance | Minimum to combustible walls (top) | 762 | mm | installation |
| Gap | Spark Plug Gap | 0.7 - 0.8 | mm (0.027 - 0.031 in) | |
| Pressure | Fuel Shutoff Solenoid Coil Voltage Threshold | 10.2 | VDC | while attempting to start |
| Pressure | Lubricating Oil Pressure at Rated Speed (Minimum) | 310 | kPa (45 psi) | at rated speed |
| Pressure | Maximum Fuel Supply Pressure (either fuel) | 3.2 | kPa (13 inch water column) | under any condition |
| Pressure | Natural Gas Fuel Supply Pressure | 3.5 - 12 | inch water column (0.9 - 3.0 kPa) | |
| Pressure | Propane Vapor Fuel Supply Pressure | 1.5 - 3.0 | kPa (6 - 12 inch water column) | |
| Resistance | Governor Actuator Resistance | 2.8 ±5% | Ohms | |
| Resistance | Rotor Ground Resistance | > 1 megohm on megger, or infinity on an ohmmeter | megohm | |
| Resistance | Rotor Winding Resistance F1 to F2 (13 kW) | 26 +/-10% | Ohms | at 75 °F room temperature |
| Resistance | Rotor Winding Resistance F1 to F2 (17/20 kW) | 30.5 +/-10% | Ohms | at 75 °F room temperature |
| Resistance | Sense L1(W) - Sense L2(V) (13 kW) | 0.24 +/-10% | Ohms | |
| Resistance | Sense L1(W) - Sense L2(V) (17/20 kW) | 0.107 +/-10% | Ohms | |
| Resistance | Stator Ground Resistance | > 1 megohm on megger, or infinity on an ohmmeter | megohm | |
| Resistance | Stator Winding Resistance L1 to N (13 kW) | 0.112 +/-10% | Ohms | at 75 °F room temperature |
| Resistance | Stator Winding Resistance L1 to N (17/20 kW) | 0.042 +/-10% | Ohms | at 75 °F room temperature |
| Resistance | Stator Winding Resistance Q1 to Q2 (13 kW) | 2.56 +/-10% | Ohms | at 75 °F room temperature |
| Resistance | Stator Winding Resistance Q1 to Q2 (17/20 kW) | 1.45 +/-10% | Ohms | at 75 °F room temperature |
| Speed | Rated RPM | 3600 | rpm | |
| Temperature | Alternator Temperature Switch Contacts Open | 197 - 210 | °F (92 - 99 °C) | |
| Torque | AC Battery Charger Screws | 0.9 - 1.2 | Nm | |
| Torque | Access Panel Fasteners (oil drain) | 5.0 - 6.6 | Nm | |
| Torque | Air-Fuel Mixer Flange Bolts | 13 | ft-lb (17.5 Nm) | |
| Torque | Airbox Cover Bolts | 3.2 - 4.0 | Nm | |
| Torque | Airbox Mounting Brackets Bolts | 3.2 - 4.0 | Nm | |
| Torque | Airbox to Mixer/Throttle Body Nuts | 3.2 - 4.0 | Nm | |
| Torque | Alternator Fan/Rotor Retention Nut | 113 - 139 | Nm | |
| Torque | Alternator Ground Strap to Skid Bolt | 5 - 6.2 | Nm | |
| Torque | Alternator Ground Strap/B- to End Bell Bolt | 12.3 - 15 | Nm | |
| Torque | Alternator Heater | 18 - 22 | Nm | |
| Torque | Alternator Leads into Circuit Breaker | 4 - 5 | Nm | |
| Torque | Alternator Leads into Circuit Breaker: Bonding Jumper | 4 - 5 | Nm | |
| Torque | Alternator Leads into Circuit Breaker: Neutral Lead/Lug Bolt | 5.5 - 6.5 | Nm | |
| Torque | Alternator Leads into Circuit Breaker: Neutral Lug Hex Screw | 4 - 5 | Nm | |
| Torque | Battery Charge Alternator Mounting Bolts | 8 - 12 | Nm | |
| Torque | Battery Tray Bolt | 3.2 - 4 | Nm | |
| Torque | Brush Block Access Panel (Plastic) Bolt | 3.2 - 4 | Nm | |
| Torque | Brush Block Bolts | 2.3 - 3.2 | Nm | |
| Torque | Control Board Bracket to Enclosure Bolt | 9.8 - 11.9 | Nm | |
| Torque | Control Board to Bracket Mounting Bolt | 2.8 - 3.5 | Nm | |
| Torque | Crankcase Reed Valve Cover Bolts | 8 - 12 | Nm | |
| Torque | Cylinder Head Bolts | 50 | Nm | tighten in pattern shown |
| Torque | Dipstick (Shipped Separately) | 9.8 - 11.9 | Nm | |
| Torque | Enclosure Hood Hinge Assembly Bolts | 5.6 - 6.6 | Nm | |
| Torque | Enclosure M6 Bolts - All Panel Connections and Cross Bars | 5.6 - 6.6 | Nm | |
| Torque | Exhaust Baffle to Muffler Clamp Nuts | 13.9 - 16.8 | Nm | |
| Torque | Exhaust Manifold Nuts | 33 - 40 | Nm | |
| Torque | Flywheel Nut | 90 - 105 | Nm | |
| Torque | Governor Actuator Bracket to Engine Bolts | 5.0 - 6.2 | Nm | |
| Torque | Governor Actuator Mounting Bolts | 9.8 - 11.9 | Nm | |
| Torque | Head Bolts | 50 - 55 | Nm | |
| Torque | Hood Latch Bolt | 5.6 - 6.6 | Nm | |
| Torque | Inner Enclosure Panel to Skid Nuts/Bolts | 5.6 - 6.6 | Nm | |
| Torque | Intake Manifold Nuts | 11 - 14 | Nm | Locking feature of nut faces outward |
| Torque | Isolator Bolts - Alternator | 24 - 29 | Nm | |
| Torque | Isolator Bolts - Engine | 24 - 29 | Nm | |
| Torque | Lower Fuel System Mounting Bolts | 9.8 - 11.9 | Nm | |
| Torque | Mixer Fuel Inlet Fitting/Lock Nut | 58.3 - 77.3 | Nm |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Engine oil | 0W30 | Full synthetic gasoline engine oil which meets or exceeds API service SN/SN-RC and ILSAC GF-5 | 2.3 L | All temperatures, required below -17 °C (0 °F) | |
| Engine oil | 5W30 | Full synthetic gasoline engine oil which meets or exceeds API service SN/SN-RC and ILSAC GF-5 | above -17°C | 2.3 L | Temperatures above -17 °C (0 °F) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
18| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 2 | Low Oil Pressure Fault | Continuous ground (greater than or equal to 3 seconds) at the generator set control for oil pressure input. The switch opens the control circuit with pressure. | Shutdown | Measure the oil level; disconnect the oil pressure switch and measure continuity from P1-6 and GND; verify switch operation; measure oil pressure with a mechanical gauge; repair or replace relief valve and oil pump if necessary. |
| 4 | Overcrank | The generator set control did not sense alternator quad winding frequency after cycle crank (30 seconds of cranking and 15 seconds between each crank attempt for a total of 3 crank attempts). | Shutdown | Check fuel supply, air/fuel mixture, ignition system, starter, battery and wiring. Check air filter and exhaust. Measure quad voltage during cranking and winding resistances. |
| 12 | Overvoltage | Instantaneous Fault: AC voltage S1-S2 greater than 300 VAC. Delayed Fault: AC voltage line-to-line greater than 268 VAC but less than 300 VAC for 3 continuous seconds. | Shutdown | Measure AC voltage at the circuit breaker and pins P1-34/P1-35. Cycle loads. Reseat P1. Measure field, quadrature and main winding resistance. |
| 13 | Undervoltage | AC voltage 240 line-to-line is less than 216 VAC for 5 continuous seconds. | Shutdown | Measure AC voltage and frequency. Balance loads within 10% line-to-line. Reseat P1. Measure winding resistance and check brush alignment. |
| 14 | Overfrequency | Instantaneous Fault: Frequency greater than 72 Hz. Delayed Fault: Frequency greater than 66 Hz but less than 72 Hz for 6 continuous seconds. | Shutdown | Measure AC current and frequency. Check exhaust, fuel supply, governor actuator, demand regulator and throttle plate. Measure winding resistance and check brush alignment. |
| 15 | Underfrequency | Frequency less than 54 Hz (for the 60 Hz model) for 8 continuous seconds. | Shutdown | Measure AC current, frequency and load capability. Check air filter, exhaust, fuel supply, governor and ignition. Measure winding resistance and check brush alignment. |
| 19 | Governor Actuator Shutdown | Controller sensed governor actuator circuit is open or shorted. | Shutdown | Measure and verify governor actuator resistance (2.8 Ohms ±5%). Verify governor wiring to the control. Replace if necessary. |
| 22 | Governor Actuator Overload | Maximum governor output (PWM) for 10 continuous seconds. | Shutdown | Measure AC current. Check air filter, fuel supply, intake manifold and gaskets, exhaust and ignition. Verify the actuator function and check the governor linkage. |
| 27 | Voltage Sense Lost | The generator set frequency is greater than 40 Hz and voltage sensed is less than 5 VAC on one or both lines. | Shutdown | Measure the AC voltage. Reseat P1. Measure field, quadrature and main winding resistance. Check brush alignment. |
| 29 | High Battery Voltage | DC voltage to controller greater than 19 VDC. | Shutdown | Measure DC voltage at the battery, at the generator set and at connector P1. Measure DC voltage with the battery charger turned on and diagnose the faulty charger. |
| 32 | Low Cranking Speed Sense | Quadrature frequency is less than 1 Hz (engine RPM is less than 180) for 3 continuous seconds after pressing start. | Shutdown | Check battery and connections. Verify engine and alternator rotation. Check J1 pins. Measure DC voltage at the starter. Check air filter, exhaust, fuel supply and ignition. |
| 35 | Control Card Failure | EEPROM (programming variables) error during self-test. | Shutdown | Replace the control. |
| 36 | Generator Set Stopped Without Fault Condition | RPM is less than 500 and sense voltage S1-S2 is at 0 VAC and no other fault condition occurred. | Shutdown | Verify engine and alternator rotation. Check air filter, exhaust, fuel supply, governor and ignition. Measure winding resistance. |
| 37 | Invalid Set Configuration | Generator set control configuration does not meet any valid configuration. | Shutdown | Using the display, reset and save the generator set configuration. If correct and the fault will not clear, replace the control. |
| 43 | Processor Fault | RAM (programming variables) error during self-test. | Shutdown | Replace the control as necessary. |
| 45 | Speed Sense Fault | While running, the quadrature frequency dropped to 0 Hz for 1 continuous second. | Shutdown | Inspect and clean slip rings. Measure quadrature winding resistance between P1-2 and P1-3. Check harness continuity. Measure frequency and droop. |
| 46 | Generator Set Overload | The total generator set load is above 105% of rated. | Shutdown | Measure the AC current and voltage while running with all connected loads. Identify faulty or short cycling loads and reduce loads as necessary. |
| 76 | Alternator Over Temp | The temperature at the alternator is too high. The high temperature switch opens between 197 - 209 °F (91.5 - 98.5 °C). An open condition on this circuit triggers the fault. | Shutdown | Verify the air inlet and air outlet panels are not obstructed. Measure the temperature sensor wiring (P1-33 to GND) for continuity. Inspect the cooling fan. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Converting the Fuel System Type adjustment
⚠ Do not rotate the center section of the valve beyond the detent.
Tools: 6 mm external hex wrench
- From the Main screen, select Menu; hold the Next key at least 5 seconds to view the Config Menu.
- Highlight 'Config' and click Enter. Use the Next key to navigate to the Fuel Type field; select NG or LP.
- Do not change the number in the Config field.
- Use a 6 mm external hex wrench to rotate the center section of the fuel valve.
- Turn the center section clockwise until the detent is reached; do not rotate beyond this point.
- Keep selecting the Back button to save the settings and return to the Main screen.
Generator Config Screen Setup adjustment
⚠ Failure to configure will result in Fault Code 37.
- From the Main screen, select Menu.
- Press and hold the Next key on the Menu screen for at least 5 seconds to view the Config Menu.
- Highlight 'Config' and click the Enter key. The Generator Config screen appears.
- Use the Next key to navigate to the Config field. Use the arrow keys to select the appropriate config option (20 = C20N6H/C20N6HC, 21 = C17N6H, 22 = C13N6H).
- Use the Next key to navigate to the Fuel Type field. Select NG (natural gas; default) or LP (liquid propane).
- Keep selecting the Back button to save the settings and return to the Main screen.
Fuel Shutoff Solenoid Troubleshooting diagnostic
Tools: Multi-meter, Soapy water solution
- Disconnect the four harness leads from the fuel solenoid coils.
- Check that battery voltage is being supplied through the generator set harness using a multi-meter between FSOL1+/FSGND1 and FSOL2+/FSGND2 while trying to start.
- Verify that the voltage is 10.2 VDC. If no voltage, check for bad wiring; if less than 10.2 VDC, check for bad wiring or discharged battery.
- Check for proper solenoid operation by applying 12 VDC to a coil and listening/feeling for activation. Repeat for all solenoids.
- If either solenoid does not activate, replace the gas valve assembly.
- Check for fuel leaks at the solenoid with a soapy water solution on pipe threads and around the base; tighten or replace as required.
Line Circuit Breaker Troubleshooting diagnostic
⚠ Automated Machinery: accidental or remote starting can cause severe personal injury or death.
Tools: Ohmmeter
- Shut down and disable the generator set; disconnect the negative (–) battery cable and reconnect it last when done.
- Disconnect the leads going into and out of the circuit breaker (two leads from the alternator at the top L1 and L2, and two from customer wiring at the bottom L1 and L2).
- Check continuity: with the breaker on, very low resistance between the L1 lugs and between the L2 lugs.
- With the breaker off, the continuity check between L1 and L2 pairs should show open.
- Replace the breaker if either of the continuity tests fails.
Testing the Alternator diagnostic
⚠ Disconnect the AVR before doing any insulation resistance test. Discharge the windings by shorting to earth through an earthing rod for at least 5 minutes.
Tools: Ohmmeter, Megger or insulation resistance meter, Wheatstone bridge (0.001 Ohms precision)
- Test the rotor for grounded, open and shorted windings using an ohmmeter, testing at the brush block terminals first.
- For rotor ground resistance, set the ohmmeter to the highest scale or use a megger; touch one probe to the rotor shaft and the other to a slip ring.
- For rotor winding resistance, connect each meter test lead to a separate slip ring and compare to the resistance table.
- Test for a short between the main windings and the quad windings.
- For stator ground resistance, touch one test probe to the stack and, in turn, the other to each stator lead.
- Measure stator winding resistance with a meter having precision down to 0.001 Ohms.
- Measure each winding to the stator laminations to check for bad insulation.
Adding Oil maintenance
⚠ Ensure that the generator set engine has cooled down before adding or draining the oil.
- Ensure that the oil fill cap area is clean, and prevent debris from entering the engine.
- Add the appropriate amount of oil, based on the engine oil level check.
- Recheck the engine oil level. Based on the results, add or drain oil.
- Clean up and dispose of any oil in accordance with local/state regulations.
Brush Block/Slip Ring Service maintenance
⚠ Make sure the brushes are aligned correctly with the slip rings; otherwise they may break when the generator set is started.
Tools: Scotch Brite pad or commutator stone
- Disconnect the field leads from the brush block (F1, F2).
- Remove the two mounting screws.
- Withdraw the brush block from the alternator end bell.
- Inspect the brush block: if either brush is shorter than 11 mm (7/16 inch), binds, or is damaged, replace the brush block assembly.
- When installing the brush block, keep the brushes retracted with the wire through the hole; remove the wire after bolting the block in place.
- If the slip rings have grooves, pits, or other damage, use a Scotch Brite pad or commutator stone to remove light wear or corrosion.
Changing Engine Oil and Oil Filter maintenance
⚠ Contact with used engine oil can cause cancer or reproductive toxicity.
⚠ Accidental or remote starting can cause severe personal injury or death.
- Open the generator set's circuit breaker to prevent the ATS from transferring to generator set source when manually starting.
- Manually start the generator set and allow it to run 2 to 5 minutes to warm the engine oil.
- Remove the access panels to get to the drain hose.
- Stop the generator set and allow it to thoroughly cool. Disconnect the battery charger and the negative (–) battery cable.
- Open the oil drain cap to release oil from the engine into the appropriate container, close it, and wipe it clean.
- Place an appropriate container below the oil filter. Remove the oil filter by turning it counterclockwise and remove the old gasket.
- Clean the filter mounting surface on the engine block.
- Make sure the gasket is in place on the new filter and apply a thin film of clean oil to the gasket.
- Install the new filter until the gasket just touches the block. Turn it an additional 1/2 to 3/4 turn. Do not over-tighten.
- Add the appropriate amount of oil and check the engine oil level.
- Reconnect the battery cables, positive (+) cable first, and reconnect the battery charger.
- Operate the generator set with no load for approximately 5 minutes to check for leaks at the oil filter or oil drain hose.
- Shut down the generator set, wait 5 minutes, and confirm the correct oil level. Check for leaks and repair any identified.
- Dispose of the used oil and oil filter according to local environmental regulations.
- Re-install the access panels and restore the original generator set settings, then close the generator set breaker.
Checking Engine Oil Level maintenance
⚠ Do NOT check oil while the generator set is operating.
⚠ Overfilling can cause foaming or aeration of the oil.
- Make sure that the generator set has not been running for approximately five minutes.
- Clean off the area surrounding the dipstick port and prevent debris from entering the engine.
- Pull out the dipstick and wipe it clean.
- Reinsert and fully seat the dipstick.
- Remove the dipstick and check the oil level.
- Reinsert and fully seat the dipstick.
Draining Excessive Oil maintenance
- Remove the access panels to get to the drain hose.
- Place the end of the drain hose into an appropriate container.
- Open the oil drain cap to release oil from the engine into the appropriate container.
- Re-check the engine oil level. Based on the results, add or drain oil.
- When a sufficient amount of oil has been drained, close the oil drain cap and wipe it clean.
- Re-install the access panels. Torque the fasteners 3.5 - 5.0 ft-lb (5.0 - 6.6 Nm).
- Dispose of the used oil in accordance with local and state regulations.
Immobilize the Generator Set maintenance
⚠ Accidental or remote starting of the generator set can cause severe personal injury or death.
Tools: Insulated wrench, E-Stop button
- Press the Off switch from the display and then press the E-Stop button to shut down the engine.
- Thoroughly ventilate the generator set before disconnecting any leads.
- Turn off and disconnect the heater (where fitted) from the AC source before disconnecting the battery cables.
- Turn off and disconnect the battery charger (where fitted) from the AC source.
- Turn off the fuel supply to the engine.
- Disconnect the battery. Disconnect the negative (–) cable first, using an insulated wrench.
- Place warning notices at each location that state, 'Maintenance in Progress – Immobilized for Safe Working.'
Clock Setup operation
- From the Main screen, select Menu. Use the arrow keys to highlight Clock. Select the Enter key.
- Use the arrow keys to set the time and date. Select the Next key to go to the Daylight Savings screen.
- Use the arrow keys to enable/disable Daylight Savings. If enabling, select Next to highlight the Offset field.
- Use the arrow keys and Next key to set the offset value for Daylight Savings time.
- Select Next to set when Daylight Savings starts: set Month (1 – 12), Week (0 – 5), Day (Sun – Sat) and Hour (12AM – 12PM).
- Select Next to set when Daylight Savings ends using the same fields.
- Keep selecting the Back button to save the settings and return to the main screen.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What is the power rating of the Cummins/Onan C17 N6H?
The Cummins/Onan C17 N6H is rated 17 kW standby.
What kind of fuel does the Cummins/Onan C17 N6H run on?
The Cummins/Onan C17 N6H runs on Natural Gas or Propane Vapor.
What is the oil capacity of the Cummins/Onan C17 N6H?
The Cummins/Onan C17 N6H has an engine oil capacity of 2.3 liters (2.4 US quarts), per the manufacturer specification sheet.
What is the dry weight of the Cummins/Onan C17 N6H?
The Cummins/Onan C17 N6H has a dry weight of 241 kg (531 lb).
What voltage does the Cummins/Onan C17 N6H produce?
The Cummins/Onan C17 N6H is offered in 120/240 V, Single Phase-phase.
What size battery does the Cummins/Onan C17 N6H need?
The Cummins/Onan C17 N6H uses 12 V each, 450 CCA, group 51, per the manufacturer specification sheet.
Repair guides
19- Alternator and Engine Installation
- Alternator and Engine Removal
- Brush Block/Slip Ring Service
- Changing Engine Oil and Oil Filter
- Clock Setup
- Complete System Test
- Control Board Replacement
- Converting the Fuel System Type
- Cylinder Head Assembly Replacement
- Draining Excessive Oil
- Exercise Setup
- Fuel Shutoff Solenoid Troubleshooting
- Generator Config Screen Setup
- Governor Actuator Installation
- Governor Actuator Removal
- Immobilize the Generator Set
- Line Circuit Breaker Troubleshooting
- Mode Setup (Remote and Standby)
- Testing the Alternator
Step-by-step procedures compiled from the Cummins/Onan service manual for this model.
Parts
59model family| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 0187-5128 | Clamp | 1 | Clamp | buy |
| 0332-1794 | Tie, Cable | 3 | Cable tie | buy |
| 0505-0037 | Elbow, Pipe | 1 | Elbow pipe | buy |
| 0505-0084 | Fitting, Nipple | 1 | Nipple fitting | Amazon eBay |
| 0505-0332 | Fitting, Nipple | 1 | Nipple fitting | Amazon eBay |
| 0815-0578 | Screw, Hollow Head | 4 | Screw | buy |
| 0815-0941-03 | Screw, Hollow Head | 2 | Screw | buy |
| 0870-2193-04 | Nut, Torque Hexagon | 4 | Nut | buy |
| A026E601 | Adapter, Straight | 1 | Adapter | buy |
| A041G806 | Switch, Oil Pressure (Installed 7-10 PSI Normally Closed) | 1 | Oil pressure switch | buy |
| A044C288 | Label, Logo (Black Lettering) | 1 | Label | buy |
| A044M619 | Label, Information | 1 | Label | buy |
| A044Y564 | Label, Warning | 1 | Label | buy |
| A048G917 | Label, Caution | 1 | Label | buy |
| A048G921 | Label, Warning | 1 | Label | buy |
| A049K306 | Label | 1 | Label | buy |
| A049V296 | Gasket | 2 | Gasket | buy |
| A050B086 | Oil, Lubricating | 0.6 | Fluid | Amazon eBay |
| A050U655 | Clamp | 1 | Clamp | buy |
| A050X362 | Filter, Oil | 1 | Oil filter | Amazon eBay $31.90 |
| A051A078 | Filter, Air | 1 | Air filter | buy |
| A051A232 | Valve, Solenoid | 1 | Solenoid valve | buy |
| A052E058 | Label, Warning | 1 | Label | buy |
| A052G373 | Pipe, Exhaust | 1 | Exhaust pipe | buy |
| A052J269 | Bracket, Fuel System | 1 | Fuel bracket | buy |
| A052Y175 | Hose, Fuel | 1 | Fuel hose | buy |
| A053A320 | Regulator, Pressure | 1 | Pressure regulator | buy |
| A053A324 | Seal, Edge | 1 | Seal | buy |
| A053B918 | Silencer | 1 | Silencer | buy |
| A053C985 | Valve, Fuel | 1 | Fuel valve | buy |
| A054V783 | Label, Caution | 1 | Label | buy |
| A054V975 | Label, Package | 1 | Label | buy |
| A054Z620 | Head, Cylinder (Cylinder 2) | 1 | Cylinder head | buy |
| A054Z621 | Head, Cylinder (Cylinder 1) | 1 | Cylinder head | buy |
| A054Z623 | Arm, Rocker | 4 | Rocker arm | buy |
| A054Z625 | Rod, Push | 4 | Push rod | buy |
| A054Z627 | Gasket, Cylinder Head | 2 | Gasket | buy |
| A054Z629 | Starter | 1 | Starter | buy |
| A054Z630 | Coil, Ignition (Cylinder 1 - Black) | 1 | Ignition coil | buy |
| A054Z631 | Coil, Ignition (Cylinder 2 - White) | 1 | Ignition coil | buy |
| A054Z635 | Flywheel Assembly (Ring Gear, Magnets, Flywheel) | 1 | Flywheel | buy |
| A054Z636 | Key, Flywheel (Not Shown) | 1 | Key | buy |
| A054Z637 | Cooler, Oil | 1 | Oil cooler | buy |
| A054Z638 | Hose, Oil Cooler | 2 | Hose | buy |
| A054Z640 | Dipstick | 1 | Dipstick | buy |
| A054Z641 | Cap, Oil Fill | 1 | Cap | buy |
| A057E896 | Coupling, Pipe | 1 | Pipe coupling | buy |
| A057E899 | Plug, Threaded | 1 | Threaded plug | buy |
| A057K127 | Insulation, Cap | 1 | Insulation cap | buy |
| A057S041 | Fitting, Nipple | 1 | Nipple fitting | buy |
| A057Z280 | Heater, Flexible (Pressure Regulator) | 1 | Flexible heater | buy |
| A058F810 | Label, Information | 1 | Label | buy |
| A060L981 | Block, Engine Long - Complete | 1 | Cylinder head | buy |
| A061D045 | Hose/Valve, Drain (Spec A & B) | 1 | Drain valve | buy |
| A061K994 | Plug, Spark (K7RTJC-5) | 1 | Spark plug | Amazon eBay $7.50 |
| A061N230 | Label | 1 | Label | buy |
| A062W789 | Valve, Drain (Begin Spec B) | 1 | Drain valve | buy |
| A043J735 | Enclosure Touch Up Paint (Sandstone) | 1 | Service part / kit | buy |
| A061M241 | Label, Warning | A/R | Service part / kit | Amazon eBay |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Available documents
This page was generated from the 8 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.