  • Automated Machinery: accidental or remote starting can cause severe personal injury or death.

Procedure

  1. Shut down and disable the generator set; disconnect the negative (–) cable first, then the positive cable.
  2. Open the hood and make sure the hood latch drops into place.
  3. Remove the control access panel.
  4. Remove all wiring harness plugs from the control board, P1, P2, and the optional Ethernet cord.
  5. Remove the bolt retaining the control board. Remove and replace the control board.
  6. Re-install the 2 wiring harness plugs P1 and P2 only. Do not reconnect the optional Ethernet cord yet.
  7. Reconnect the generator set battery, positive cable first.
  8. Enter the serial number and product code from the generator set nameplate via the Nameplate Config screen.
  9. Set the generator output and fuel type in the Generator Config screen.
  10. Optional: Re-install the Ethernet cord into the control.
  11. Install the control access panel and close the hood.

Specs & values

  • Model number must be in the 8-digit 'A054_###' format

Full service-parts list: Cummins/Onan C20 N6 →

Source: Cummins/Onan service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.