Service parts for the C32
Grouped by system, with how many of each the parts manual calls for.
Air intake
1 requiredFuel system
1 requiredOil system
1 requiredCooling system
1 requiredElectrical
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | diesel |
|---|---|
| Frequency | 50.0 Hz |
| Standby power | 1000 kW |
| Standby kVA | 1250 |
| Prime power | 880 kW |
| Emissions | Low BSFC |
| Controller | EMCP 4.2B, EMCP 4.4 |
| Oil capacity | 4730.0 L |
| Voltage options | 480 V |
| Phase | 3 |
| Power factor | 0.8 |
| Circuit breaker | 1600 A |
| Battery group | 31 |
| Battery cranking | 1400 CCA |
| Battery voltage | 24V V |
| Battery quantity | 1 |
| Coolant capacity | 138 L |
| Max ambient | 32 °C |
| Dry weight | 7131 kg |
Engine
| Oil capacity | 4730.0 L |
|---|---|
| Coolant capacity | 5000.0 L |
| Displacement | 32.1 L |
| Aspiration | turbocharged |
| Rated speed | 1800 rpm |
Filters for the Caterpillar C32
3Engine-mounted filters the filter manufacturers list for this engine family. These come from the engine, not from this generator set’s own parts list, so confirm against your serial number before ordering.
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Oil filter | P551808 | Lube Filter, Spin-On Full Flow | CATERPILLAR 1R1808, CATERPILLAR 1R808, NAPA 7792, BALDWIN B7299 | KuduParts $80.00 |
| Fuel filter | P551316 | Fuel Filter, Spin-On | CATERPILLAR 1R0755, CATERPILLAR 3890433, NAPA 3685, BALDWIN BF7639 | KuduParts $54.00 FridayParts $55.99 |
Listed for this engine in only one kind of machine, so they may depend on how the engine was installed:
| System | Filter | Description | Cross-references | |
|---|---|---|---|---|
| Fuel / water separator | P552023 | Fuel Filter, Water Separator Cartridge | CATERPILLAR 4P7384, CATERPILLAR 5134491, BALDWIN PF7890, EPIROC 57269037 | buy |
Maintenance & consumables
for the Caterpillar C32| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | CLEANER GP-AIR-D | 4350408 | eBay | ||
| Fuel filter | — | ||||
| Fuel filter | Fuel Secondary - ADV | 1R-0762 | Amazon eBay $33.99 eBay $34.95 NAPA $43.65 FridayParts $30.63 | ||
| Oil filter | Engine Oil - ADV | 1R-1808 | Amazon eBay $141.00 eBay $59.99 NAPA $45.70 NAPA $45.70 KuduParts $80.00 FridayParts $81.99 | ||
| Battery | 24V wet, 1125 CCA, group 31 | 7L7871 | eBay | ||
| Belt | — | ||||
| Coolant | Extended Life Coolant (ELC) | 138.0 L | 1195148 | eBay | |
| Oil | — | ||||
| Spark plug | — |
Service intervals
40| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Belts | Inspect | 250 hr | 6 mo | First service — Initial 20 to 40 Service Hours - Inspect/Adjust/Replace |
| Engine oil (S-O-S oil sample) | Test | 125 hr | Severe service occurs at high loads, in high temperatures, and in dusty conditions | |
| Aftercooler Core | Clean | 250 hr | Every 250 Service Hours - Clean/Test | |
| Battery Electrolyte Level | Check | 250 hr | Every 250 Service Hours | |
| Coolant (S-O-S coolant analysis Level 1) | Test | 250 hr | Cat ELC - Every 250 Hours; also the recommended sampling interval for all conventional heavy-duty coolant/antifreeze and for commercial coolants that meet Cat EC-1 | |
| Electronic Unit Injector | Inspect | 3000 hr | First service — Initial 250 Service Hours - Inspect/Adjust | |
| Electronics Grounding Stud | Inspect | 250 hr | Every 250 Service Hours - Inspect/Clean/Tighten | |
| Engine Air Cleaner Element (Single Element) | Replace | 250 hr | Every 250 Service Hours | |
| Engine Valve Lash | Adjust | 3000 hr | 12 mo | First service — Initial 250 Service Hours (Standard): Inspect/Adjust |
| Engine Valve Lash | Inspect | 4000 hr | First service — Initial 250 Service Hours - Inspect/Adjust | |
| Engine Valve Rotators | Inspect | 3000 hr | First service — Initial 250 Service Hours | |
| Engine crankcase oil (S-O-S oil sample) | Test | 250 hr | Table 6 S-O-S Oil Sampling Interval; severe applications may require a more frequent oil sampling interval | |
| Fuel Injector | Adjust | 250 hr | 12 mo | First service — Initial 250 Service Hours (Standard): Inspect/Adjust |
| Primary air filter element | Change | 250 hr | When changing the primary element at 250 operating hours (basis of the without-indicator filter-change comparison) | |
| SCA (Supplemental Coolant Additive) concentration | Test | 250 hr | Test the concentration of SCA or submit a coolant sample at 250 hour intervals or at PM Level 1 intervals; check at every oil change or every 250 hours, whichever occurs first | |
| Coolant (S-O-S coolant analysis Level 2) | Test | 500 hr | 12 mo | First service — For new systems, refilled systems, and converted systems that use Cat ELC or Cat DEAC; also every year; use the interval that occurs first |
| Cooling System Coolant Sample (Level 2) | Other | 500 hr | 12 mo | First service — Initial 500 Hours (for New Systems, Refilled Systems, and Converted Systems) - Obtain |
| Secondary air filter element | Change | 750 hr | When changing the secondary element at 750 operating hours (basis of the without-indicator filter-change comparison) | |
| Cooling System Coolant (DEAC) | Change | 3000 hr | 36 mo | Every 3000 Service Hours or 3 Years |
| Cooling System Water Temperature Regulator | Replace | 3000 hr | 36 mo | Every 3000 Service Hours |
| Engine Mounts | Inspect | 3000 hr | Every 3000 Service Hours | |
| Engine Speed/Timing Sensors | Check | 3000 hr | Every 3000 Service Hours - Check/Clean/Calibrate | |
| Turbocharger | Inspect | 5000 hr | 36 mo | Every 5000 Service Hours |
| Cat ELC Extender addition (cooling system) | Other | 6000 hr | Treat the cooling system with Cat ELC Extender at 6000 hours or one half of the coolant service life | |
| Cooling System Coolant Extender (ELC) | Other | 6000 hr | 36 mo | Every 6000 Service Hours or 3 Years: Add |
| Fan Drive Bearing | Replace | 8000 hr | Every 8000 Service Hours | |
| Rotating Rectifier | Check | 8000 hr | 36 mo | Every 8000 Service Hours (Standard) |
| Overhaul (Top End) | Other | 9000 hr | Every 605 670 L (160 000 US gal) of fuel or 9000 Service Hours - C27 | |
| Coolant (Cat ELC) | Change | 12000 hr | 12000 service hours or six years; use the interval that occurs first | |
| Cooling System Coolant (ELC) | Change | 12000 hr | 72 mo | Every 12000 Service Hours or 6 Years |
| Overhaul (Major) | Other | 18000 hr | Every 1 211 330 L (320 000 US gal) of fuel or 18 000 Service Hours - C27 | |
| Alternator | Inspect | 6000 hr | 72 mo | Every Year (Standby); Every 6000 Service Hours or 6 Years (Standard) |
| Batteries | Replace | 36 mo | Every 3 Years (Standby); When Required (Standard) | |
| Coolant (S-O-S coolant analysis Level 1 and Level 2) | Test | 12 mo | Cat DEAC - Yearly | |
| Cooling System Coolant Sample (Level 1) | Other | 250 hr | 6 mo | Every 6 Months (Standby): Obtain; Every 250 Service Hours (Standard) |
| Cooling System Supplemental Coolant Additive (SCA) | Test | 250 hr | 6 mo | Every 6 Months (Standby): Test/Add; Every 250 Service Hours (Standard) |
| Crankshaft Vibration Damper | Inspect | 3000 hr | 12 mo | Every Year (Standby); Every 228000 L fuel or 3000 Service Hours (Standard) |
| Engine | Clean | 3000 hr | 12 mo | Every Year (Standby); When Required (Standard) |
| Engine Air Cleaner Element (Dual Element) | Clean | 250 hr | 12 mo | Every Year (Standby): Clean/Replace; Every 19000 L fuel or 250 Service Hours (Standard) |
| Engine Crankcase Breather | Clean | 500 hr | 12 mo | Every Year (Standby); Every 38000 L fuel or 500 Service Hours (Standard) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
60| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Clearance | Belt deflection | 9 to 15 | mm (0.35 to 0.59 inch) | 110 N (25 lb ft) force applied midway between the pulleys |
| Clearance | Coolant level below bottom of filler pipe / sight glass level | 13 | mm (0.5 inch) | engine stopped and cool |
| Other | Bearing bracket sleeve step minimum | 0.0762 | mm | |
| Other | Cat Fast Acting Cooling System Cleaner concentration | 0.5 | L (1 pint) per 15 L (4 US gal) of cooling system capacity | cooling systems with normal deposits |
| Other | Cooling system fill rate | 19 | L (5 US gal) per minute | no faster than, to avoid air locks |
| Other | Gross Input Torque (TH55-E70) | 12 667 | N•m (9350 lb-ft) | |
| Other | Gross Input Torque (TH55-E90) | 12 677 | N•m (9350 lb-ft) | |
| Other | Hydrosolv liquid cleaner concentration | two to five | percent | at temperatures up to 93°C (200°F) |
| Other | Radiator cooling package design ambient temperature | 48.9 | °C (120° F) | with 50/50 water/Extended Life Coolant mixture |
| Other | Radiator cooling package maximum elevation | 1524 | m (5000 ft) | with 50/50 water/Extended Life Coolant mixture |
| Other | Speed/timing sensor sliphead extension (install) | minimum 4 | mm | |
| Other | Speed/timing sensor sliphead push-in force | at least 22 | N | from extended position |
| Other | Stall Torque Ratio (TH55-E70) | 2.23 | ||
| Other | Stall Torque Ratio (TH55-E90) | 2.23 | ||
| Other | Supplemental coolant additive (SCA) concentration - conventional coolant | 6 | percent | do not exceed |
| Other | Supplemental coolant additive (SCA) concentration - water and SCA systems | 8 | percent | do not exceed |
| Pressure | Air inlet filter differential pressure (clean filter) | 0.15 | kPa | |
| Pressure | Maximum air pressure at the nozzle for cleaning | 205 | kPa (30 psi) | less than |
| Pressure | Maximum air pressure for cleaning | below 205 | kPa | |
| Pressure | Maximum filtered dry air pressure for air cleaner cleaning | 207 | kPa (30 psi) | maximum |
| Pressure | Maximum water pressure for cleaning | 275 | kPa (40 psi) | less than |
| Pressure | Maximum water pressure for cleaning | below 275 | kPa | |
| Pressure | Primary filter/water separator element change point (vacuum gauge) | 50 to 70 | kPa (15 to 20 inches Hg) | |
| Pressure | Primary filter/water separator element change pressure | 50 to 70 | kPa | |
| Pressure | WS255 pump plunger load | 238,000 | lb (107,960 kg) | |
| Pressure | WS273XD pump plunger load | 275,000 | lb (124 738 kg) | |
| Pressure | WS305XD pump plunger load | 250,000 | lb (113 398 kg) | |
| Resistance | Exciter armature (rotor) L2 | less than 0.1 | ohms | |
| Resistance | Exciter field (stator) L1 winding | approximately 3.0 to 6.0 | ohms | at room temperature |
| Resistance | Main armature (stator) L4 | less than 0.1 | ohms | |
| Resistance | Main field (rotor) L3 winding | approximately 1.25 to 2.0 | ohms | at room temperature |
| Resistance | Pilot exciter armature L5 | less than 0.1 | ohms | |
| Resistance | Three-diode rectifier block forward reading | 0.4 to 1.0 | meter on diode range | |
| Resistance | Varistor CR7 | minimum 15000 | ohms | |
| Speed | Engine speed for cooling system air purge | 1500 | rpm | |
| Speed | Maximum Input Speed (TH55-E70/TH55-E90 transmissions) | 1970 | rpm | |
| Speed | Rated Input Speed (TH55-E70/TH55-E90 transmissions) | 1900 | rpm | |
| Temperature | Air cleaner oven drying maximum temperature | 82 | °C (160 °F) | do not exceed |
| Temperature | Air cleaner wash tank maximum temperature | 60 | °C (140 °F) | with warm water and cleaning agent |
| Temperature | Ball bearing installation heating | 107 | °C | ten minutes, induction heater |
| Temperature | Coolant temperature during DEAC cooling system cleaner flush | 82 | °C (180 °F) | at least, run at low idle minimum of 30 minutes |
| Temperature | Coolant temperature during ELC cooling system flush | 49 to 66 | °C (120 to 150 °F) | run at low idle until temperature reached |
| Temperature | Coolant temperature for cleaning system flush (DEAC change) | 82 | °C | minimum |
| Temperature | Generator bearing RTD alarm | 85 | °C | |
| Temperature | Generator bearing RTD shutdown | 95 | °C | |
| Temperature | Hub installation heating | 400 | °C | three hours |
| Temperature | Jacket water heater maintained coolant temperature at 0 °C ambient | 32 | °C | approximately |
| Temperature | Maximum winding temperature when drying generator | 85 | °C | |
| Temperature | Oven method generator drying temperature | 65 | °C | four hours, forced air oven |
| Temperature | Stator winding alarm setpoint (continuous) | 155 | °C | |
| Temperature | Stator winding alarm setpoint (standby) | 180 | °C | |
| Temperature | Stator winding shutdown setpoint (continuous) | 165 | °C | |
| Temperature | Stator winding shutdown setpoint (standby) | 190 | °C | |
| Torque | Air cleaner service indicator | 2 | N·m | |
| Torque | Air compressor SAE "A" hydraulic pump drive maximum torque (374 L/min and 467 L/min compressors) | 60 | N•m (44 lb-ft) | C7, C9 ACERT |
| Torque | Engine speed/timing sensor | 40 ± 5 | N·m | |
| Torque | Service indicator | 2 | N·m (18 lb in) | when a new service indicator is installed |
| Voltage | Generator set functional test minimum measured voltage | 85 | VAC | |
| Voltage | Insulation test voltage (units 600 V or less) | 500 | V | |
| Voltage | Insulation test voltage (units more than 600 V) | 1000 | V |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | 155L EXTENDED LIFE COOLANT | Part COOL001 | |||
| Coolant | 50/50 mixture water/Caterpillar Extended Life Coolant | below 48°C | Radiator cooling packages designed for up to 48.9° C (120° F) ambient; coolant sump refill capacities vary by oil sump/pan (18 L to 106 L service refill with new oil filter change) | ||
| Coolant | COOLANT-LONG LIFE-BULK-1 LITER | Part 1195148, order qty 155 | |||
| Coolant | Cat DEAC | Diesel; 3,000 Service Hours or Three Years; annual S·O·SSM Level 2 coolant sampling and analysis | |||
| Coolant | Cat DEAC (Diesel Engine Antifreeze/Coolant) | Acceptable coolant; commercial heavy-duty antifreeze/coolant must meet ASTM D4985 or ASTM D6210 | Conventional heavy-duty coolant/antifreeze. Caterpillar recommends a 1:1 mixture of water and glycol. Do not use a commercial coolant/antifreeze that only meets the ASTM D3306 specification. Do not use Cat SCA at the initial fill when Cat DEAC is used. | ||
| Coolant | Cat ELC | Diesel; 12,000 Service Hours or Six Years; add Cat ELC Extender at 6,000 service hours or one half of service life; annual S·O·SSM Level 2 coolant sampling and analysis | |||
| Coolant | Cat ELC (Extended Life Coolant) | Caterpillar EC-1 specification (preferred); also meets ASTM D4985, ASTM D6210, and ASTM D3306 | Service life of 12000 service hours or six years. Premixed ELC provides freeze protection to -37 C (-34 F); ELC Concentrate can be used to lower the freezing point to -52 C (-62 F). An Extender is the only additional maintenance needed at 6000 service hours or one half of the ELC service life. Cat ELC cooling systems can withstand contamination to a maximum of ten percent of conventional heavy-duty coolant/antifreeze and/or SCA. | ||
| Coolant | Cat ELC (Extended Life Coolant); or Cat DEAC | Caterpillar EC-1 (ELC); ASTM D4985 or ASTM D5345 (heavy-duty) | 55.0 L | 1:1 mixture of water and glycol; engine only capacity 55 L | |
| Coolant | Cat NGEC | Natural Gas; 16,000 Service Hours or Three Years; use interval that occurs first | |||
| Coolant | Cat SCA (Supplemental Coolant Additive) with water | SCA concentration in a cooling system that uses SCA and water should be six to eight percent by volume; do not exceed the eight percent maximum concentration. If Cat SCA is not used, the commercial SCA must provide a minimum of 2400 mg/L or 2400 ppm (140 grains/US gal) of nitrites in the final coolant mixture when used with water, and a minimum of 1400 mg/L or 1400 ppm (82 grains/US gal) with heavy-duty coolant/antifreeze. | |||
| Coolant | Commercial long life coolants | Caterpillar Engine Coolant Specification -1 (Caterpillar EC-1) | Obtain a Coolant Sample (Level 1) if the cooling system is filled with this coolant instead of Cat ELC. | ||
| Coolant | Extended Life Coolant (ELC) | 138.0 L | 138L extended life coolant; bulk coolant part 1195148, additive part 3690804 | ||
| Coolant | Glycol (ethylene glycol / propylene glycol) | Propylene glycol coolant must meet ASTM D6210-04 | Ethylene glycol: 50 percent = freeze protection -37 C (-34 F), boil protection 106 C (223 F); 60 percent = -52 C (-62 F), 111 C (232 F). Propylene glycol: 50 percent = -32 C (-26 F), 106 C (223 F). Do not use propylene glycol in concentrations that exceed 50 percent; do not use ethylene glycol in concentrations that exceed 60 percent. All Caterpillar diesel engines equipped with air-to-air aftercooling (ATAAC) require a minimum of 30 percent glycol. | ||
| Coolant | LONG LIFE COOLANT | Part LS0332 | |||
| Engine oil | Cat DEO (Diesel Engine Oil) 10W-30 and 15W-40 | Cat ECF-1 (exceeds); API CI-4, API CI-4 PLUS, API CH-4, API CG-4, API CF (Cat DEO SAE 15W-40) | Caterpillar oils are used to fill diesel engines at the factory. Non-Caterpillar commercial oils are second choice oils. Do not use API CF-4 oils in Caterpillar diesel engines. Do not use single grade API CF oils or multigrade API CF oils in 3500 Series, C175 Series and smaller DI diesel engines. | ||
| Engine oil | Cat NGEO | Natural Gas | |||
| Engine oil | Commercial oils (DI engines) | Cat ECF-1 required; API CG-4 multigrade acceptable; API CH-4, API CI-4 and API CI-4 PLUS acceptable only if the requirements of Cat ECF-1 are met; do not use API CF-4 oils | Minimum TBN must be 10 times the fuel sulfur level (ASTM D2896); minimum TBN of the oil is 5 regardless of a low fuel sulfur level. API CG-4 oils: do not exceed the standard oil drain interval. | ||
| Engine oil | Commercial oils (PC engines) | Cat ECF-1; API CH-4, API CI-4, API CI-4 PLUS (if Cat ECF-1 requirements met); API CG-4 multigrade; API CF-4 multigrade; API CF | Minimum TBN of the oil that is used in PC engines must be 20 times the fuel sulfur level; minimum TBN of new oil is five. Change the oil when the TBN deteriorates to 50 percent of the original TBN. | ||
| Engine oil | Re-refined base stock oils | Acceptable if they meet the performance requirements specified by Caterpillar; filtering is inadequate for producing high quality re-refined base stock oils. | |||
| Engine oil | Synthetic base stock oils | Acceptable if they meet the performance requirements specified for the engine compartment. Caterpillar does not recommend the automatic extension of oil drain intervals for any type of oil. | |||
| Engine oil | Cat Arctic DEO SYN SAE 0W-30 | -40°C to 30°C | Engine Crankcase; Industrial Engines | ||
| Engine oil | SAE 0W-20 | -40°C to 10°C | Table 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines) | ||
| Engine oil | SAE 0W-30 | -40°C to 30°C | Table 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines) | ||
| Engine oil | SAE 0W-40 | -40°C to 40°C | Table 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines) | ||
| Engine oil | Cat DEO SYN SAE 5W-40 | -30°C to 50°C | Engine Crankcase; Industrial Engines | ||
| Engine oil | SAE 5W-30 | -30°C to 30°C | Table 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines) | ||
| Engine oil | SAE 5W-40 | -30°C to 50°C | Table 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines) | ||
| Engine oil | Cat DEO SAE 10W-30 | -18°C to 40°C | Engine Crankcase; Industrial Engines | ||
| Engine oil | SAE 10W-30 | -18°C to 40°C | Table 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines); SAE 10W-30 is the preferred viscosity grade for the 3116, 3126, C7, C-9 and C9 diesel engines between -18 C (0 F) and 40 C (104 F) | ||
| Engine oil | SAE 10W-40 | -18°C to 50°C | Table 1 Lubricant Viscosities for Ambient Temperatures (DI diesel engines) |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Determining the cause of a plugged fuel filter (ice or wax) diagnostic
- Remove the fuel filters.
- Cut the fuel filters open.
- Inspect the fuel filter before the filter warms. The inspection will show that the filter is filled with particles of either ice or wax.
Insulation - Test diagnostic
⚠ Personal injury or death can result from electrocution
⚠ Do not touch instrument leads before discharging them
Tools: 300-8648 Insulation Testing Gp
- Take the generator out of service and inspect visually for moisture.
- Discharge the capacitance of the windings.
- Disconnect T0 from ground and disconnect regulator sensing leads.
- Connect insulation tester RED lead to ground and BLACK lead to T0.
- Set 500 V for units 600 V or less; set 1000 V for units more than 600 V.
- Apply voltage and observe readings at 30 seconds and 60 seconds.
- Record the 60 second reading, temperature and humidity; remove voltage.
- Evaluate readings against previous readings taken under similar conditions.
Rotating Rectifier - Check diagnostic
Tools: Digital multimeter
- Set the digital multimeter on the diode range and remove all rectifier leads.
- For negative block: place red lead on negative terminal, black lead on AC1, AC2, AC3; readings should be 0.4 to 1.0.
- For negative block: place black lead on negative terminal, red lead on AC1, AC2, AC3; meter should read OL.
- For positive block: place red lead on positive terminal, black lead on AC1, AC2, AC3; meter should read OL.
- For positive block: place black lead on positive terminal, red lead on AC1, AC2, AC3; readings should be 0.4 to 1.0.
- Replace the rectifier block if any reading is out of range.
Varistor - Test diagnostic
Tools: Ohmmeter, Test light
- Place an ohmmeter across the varistor; resistance should be a minimum of 15000 ohms.
- Alternatively, disconnect either lead of the varistor.
- Place a test light across the varistor; the lamp should not light.
- Reverse the test light; the lamp should still not light.
- Replace the varistor if the lamp lights in either direction.
Winding - Test diagnostic
⚠ High voltage can cause severe injury or death
Tools: 6V-7070 Digital Multimeter, 146-4080 Digital Multimeter (RS232)
- Place engine control switch in OFF; tag all starting controls.
- Disconnect batteries or disable the starting system.
- Disconnect the winding being tested from other components.
- Measure resistance of exciter armature L2 (less than 0.1 ohm).
- Measure main armature L4 (less than 0.1 ohm) and pilot exciter L5 (less than 0.1 ohm).
- Measure exciter field L1 (approximately 3.0 to 6.0 ohms) and main field L3 (approximately 1.25 to 2.0 ohms).
- Confirm no continuity to ground and no continuity between windings.
Battery Electrolyte Level - Check maintenance
⚠ All lead-acid batteries contain sulfuric acid which can burn the skin and clothing. Always wear a face shield and protective clothing when working on or near batteries.
Tools: 245-5829 Coolant Battery Tester Refractometer
- Remove the filler caps; maintain the electrolyte level to the FULL mark on the battery.
- Use distilled water, or clean water low in minerals if distilled water is not available. Do not use artificially softened water.
- Check the condition of the electrolyte with the 245-5829 Coolant Battery Tester Refractometer.
- Keep the batteries clean; clean the battery case with a baking soda/water or ammonia/water solution and rinse with clean water.
- Use fine grade sandpaper to clean terminals and cable clamps until surfaces are bright.
- Coat the clamps and terminals with 5N-5561 Silicone Lubricant, petroleum jelly or MPGM.
Battery or Battery Cable - Disconnect maintenance
⚠ The battery cover should be removed before any servicing is attempted.
⚠ Removing the battery cables or batteries with the cover in place may cause a battery explosion resulting in personal injury.
- Switch the engine to the OFF position; turn the ignition switch OFF and remove the key and all electrical loads.
- Disconnect the negative battery terminal at the battery that goes to the start switch; ensure the cable cannot contact the terminal.
- Tape the leads in order to help prevent accidental starting.
- Proceed with necessary system repairs; reverse the steps in order to reconnect all cables.
Belts - Inspect/Adjust/Replace maintenance
⚠ Replace belts that are worn or damaged. For multiple drive belts, replace belts in matched sets.
- Remove the belt guard. Inspect the condition and adjustment of the alternator belts and accessory drive belts.
- Check belt tension by applying 110 N (25 lb ft) of force midway between the pulleys; a correctly adjusted belt deflects 9 mm to 15 mm.
- To adjust an alternator belt, slightly loosen mounting bolt (2), mounting bolt (3) and adjusting nut (1).
- Move the pulley in order to adjust the belt tension.
- Tighten the adjusting nuts and mounting bolts; refer to the Specifications, SENR3130 for proper torques.
- Install the belt guard. If new belts are installed, check the belt tension again after 30 minutes at rated rpm.
Changing to Cat ELC maintenance
⚠ Do not leave an empty SCA maintenance element on a system that is filled with ELC. The element housing may corrode and leak causing an engine failure.
⚠ Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.
⚠ The cooling system cleaner must be thoroughly flushed from the cooling system. Cooling system cleaner that is left in the system will contaminate the coolant. The cleaner may also corrode the cooling system.
Tools: Caterpillar cleaner for cooling systems, 5P-3413 Pipe Sealant, Suitable containers to collect fluids
- Drain the coolant into a suitable container.
- Dispose of the coolant according to local regulations.
- If equipped, remove the empty SCA maintenance element and the element base. Plug the coolant lines or bypass the coolant lines.
- Flush the system with clean water in order to remove any debris.
- Use Caterpillar cleaner for cooling systems in order to clean the system. Follow the instructions on the label.
- Drain the cleaner into a suitable container. Flush the cooling system with clean water.
- In systems with heavy deposits, disconnect the hoses. Clean deposits and debris from the hoses and fittings. Install the hoses and tighten the hose fittings.
- Fill the cooling system with clean water and operate the engine until the engine is warmed to 49 C to 66 C (120 F to 151 F).
- Drain the cooling system into a suitable container and flush the cooling system with clean water.
- Repeat Steps 8 and 9 until the system is completely clean.
- Fill the cooling system with the Cat ELC.
- Operate the engine until the engine is warmed. While the engine is running, inspect the engine for leaks. Tighten hose clamps and connections in order to stop any leaks.
- Attach the Special Publication, PEEP5027, "Label" to the cooling system filler for the engine in order to indicate the use of Cat ELC.
Cooling System Coolant (DEAC) - Change maintenance
⚠ Hot coolant can cause serious burns. Loosen the pressure cap slowly to relieve pressure.
⚠ Use only cooling system cleaners approved for Caterpillar engines.
Tools: 9S-8140 Pressurizing Pump
- Stop the engine and allow the engine to cool. Loosen the filler cap slowly to relieve pressure; remove the cap.
- Open the cooling system drain valve or remove a drain plug; allow the coolant to drain.
- Flush the cooling system with clean water in order to remove any debris.
- Close the drain valve; clean and install the drain plugs.
- Fill with a mixture of clean water and Cat Fast Acting Cooling System Cleaner; install the filler cap.
- Start and run the engine at low idle for a minimum of 30 minutes; coolant temperature should be at least 82 °C (180 °F).
- Stop the engine and allow to cool; drain, flush with clean water and close the drain valve.
- Fill the cooling system with coolant/antifreeze; refer to Refill Capacities and Recommendations.
Cooling System Coolant (ELC) - Change maintenance
⚠ Hot coolant can cause serious burns.
⚠ Clean water only is needed when ELC is drained and replaced.
Tools: 9S-8140 Pressurizing Pump
- Stop the engine and allow the engine to cool. Loosen the filler cap slowly to relieve pressure; remove the cap.
- Open the drain valve or remove drain plugs; allow the coolant to drain.
- Flush the cooling system with clean water in order to remove any debris.
- Close the drain valve; clean and install the drain plugs.
- Fill the cooling system with clean water; install the filler cap.
- Start and run the engine at low idle until temperature reaches 49 to 66 °C (120 to 150 °F).
- Stop the engine and allow to cool; drain, flush with clean water and close the drain valve.
- Fill the cooling system with Extended Life Coolant (ELC); refer to Refill Capacities and Recommendations.
Cooling System Coolant Extender (ELC) - Add maintenance
⚠ Use only Cat Extended Life Coolant (ELC) Extender with Cat ELC.
⚠ Do NOT use conventional supplemental coolant additive (SCA) with Cat ELC.
- Loosen the cooling system filler cap slowly in order to relieve pressure; remove the cap.
- Drain enough coolant from the cooling system if necessary to add the Cat ELC Extender.
- Add Cat ELC Extender according to the requirements for your engine's cooling system capacity.
- Clean the cooling system filler cap and inspect the gaskets.
- Replace the filler cap if the gaskets are damaged; install the filler cap.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Voltage reconnection
| Voltage | Phase | Connection | Leads | Notes |
|---|---|---|---|---|
| 3 | 12 Lead Delta | T6 and T9 tied together and grounded = neutral | T2 and T10 connection is the high phase | |
| 3 | 12 Lead Wye - High Voltage | T10, T11, T12 tied together = neutral | Typical high voltage connection (Series Wye, 60 Hz) | |
| 3 | 12 Lead Wye - Low Voltage | T10, T11, T12 tied together = neutral | Typical low voltage connection (Parallel Wye, 60 Hz) | |
| 3 | 6 Lead Delta | Typical Delta Configuration (60 Hz, 6 Lead) | ||
| 3 | 6 Lead Wye | T4, T5, T6 tied together = neutral | Terminals T4, T5 and T6 become a neutral connection when tied together | |
| 240 | 3 | Delta | Produces 208 V high phase to neutral and 240 V low phase to neutral | |
| 480 | 3 | Wye | Three-phase voltage connection |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What is the power rating of the Caterpillar C32?
The Caterpillar C32 is rated 1000 kW standby (1250.0 kVA).
Which engine powers the Caterpillar C32?
The Caterpillar C32 is powered by the Caterpillar C32 engine.
What fuel does the Caterpillar C32 use?
The Caterpillar C32 runs on diesel.
What's the oil capacity on a Caterpillar C32?
The Caterpillar C32 engine in the Caterpillar C32 has an oil capacity of 4730.0 liters.
What is the cooling system capacity of the Caterpillar C32?
The Caterpillar C32 cooling system holds 138 liters (36.5 US gallons) for the radiator system including the engine, per the manufacturer specification sheet.
What is the continuous rating of the Caterpillar C32?
The Caterpillar C32 is rated 880 kW prime (1100 kVA), against 1000 kW standby.
What is the dry weight of the Caterpillar C32?
The Caterpillar C32 has a dry weight of 7131 kg (15721 lb).
What voltage does the Caterpillar C32 produce?
The Caterpillar C32 is offered in 480 V, 3-phase.
What battery does the Caterpillar C32 use?
The Caterpillar C32 uses 1 battery, 24V V each, 1400 CCA, group 31, per the manufacturer specification sheet.
Which oil filter part number does the Caterpillar C32 take?
The Caterpillar C32 uses oil filter part number 1R-1808.
Which fuel filter part number does the Caterpillar C32 take?
The Caterpillar C32 uses fuel filter part number 1R-0762.
Which air filter part number does the Caterpillar C32 take?
The Caterpillar C32 uses air filter part number 4350408.
Repair guides
23- Battery Electrolyte Level - Check
- Battery or Battery Cable - Disconnect
- Belts - Inspect/Adjust/Replace
- Belts - Inspect/Adjust/Replace
- Cooling System Coolant (DEAC) - Change
- Cooling System Coolant (ELC) - Change
- Cooling System Coolant Extender (ELC) - Add
- Cooling System Coolant Level - Check
- Cooling System Supplemental Coolant Additive (SCA) - Test/Add
- Engine Air Cleaner Element (Single Element) - Replace
- Engine Crankcase Breather - Clean
- Engine Oil and Filter - Change
- Fuel System - Prime
- Fuel System Primary Filter (Water Separator) Element - Replace
- Fuel System Primary Filter/Water Separator - Drain
- Fuel System Secondary Filter - Replace
- Fuel Tank Water and Sediment - Drain
- Hoses and Clamps - Inspect/Replace
- Rotating Rectifier - Check
- Starting the Engine (EMCP 3)
Step-by-step procedures compiled from the Caterpillar service manual for this model.
Parts
41| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 1195148 | COOLANT-LONG LIFE-BULK-1 LITER | 1 | Fluid | eBay |
| 1R-0762 | Fuel Secondary - ADV | 2 | Fuel filter | Amazon eBay $33.99 eBay $34.95 NAPA $43.65 FridayParts $30.63 |
| 1R-0770 | Fuel/Water Separator | 1 | Fuel filter | eBay $38.77 NAPA $57.83 KuduParts $22.00 FridayParts $24.00 SinoCMP $65.00 |
| 1R-1808 | Engine Oil - ADV | 1 | Oil filter | Amazon eBay $141.00 eBay $59.99 NAPA $45.70 NAPA $45.70 KuduParts $80.00 FridayParts $81.99 |
| 1U-5490 | Hydrosolv 4165 liquid cleaner, 19 L (5 US gallon) | Fluid | Amazon eBay | |
| 3690804 | ADDITIVE-COOLANT | 2 | Fluid | eBay $19.67 |
| 4350408 | CLEANER GP-AIR-D | 1 | Air filter | eBay |
| 4471546 | TRANSFORMER GP-CURRENT | 1 | Sensor | eBay |
| 5N-5561 | Silicone Lubricant | Fluid | Amazon eBay | |
| 5N9597 | VOLTAGE INDICATOR 480V, 60HZ | 1 | Sensor | eBay |
| ACL0017 | STANDARD AIR CLEANER 17 | 1 | Air filter | eBay |
| COOL001 | 155L EXTENDED LIFE COOLANT | 1 | Fluid | eBay |
| CT20006 | CT 2000:5 RATIO | 1 | Sensor | eBay |
| JWH0241 | JW HEATER - SINGLE W/PUMP 60HZ | 1 | Pump | eBay |
| LF4811 | P FRAME / R FRAME DC REGULATOR | 1 | Avr | eBay |
| LF5341 | JWH W/ PUMP - 60HZ | 1 | Pump | eBay |
| LF9848 | IVR-EM10A | 1 | Avr | eBay |
| LS0328 | ELECTRIC STARTING MOTOR-HEAVY | 1 | Starter | eBay |
| LS0332 | LONG LIFE COOLANT | 1 | Fluid | eBay |
| M-3675181 | Piston | Piston | Amazon eBay | |
| M-3758261 | Piston | Piston | Amazon eBay | |
| M-4599781 | Gasket Set - Oil Cooler & Lines | Gasket | Amazon eBay | |
| M-CK3675181P | Cylinder Kit | Cylinder kit | Amazon eBay | |
| M-CK3758261P | Cylinder Kit | Cylinder kit | Amazon eBay | |
| 1535710 | BATTERY-WET | 2 | Service part / kit | Amazon eBay $299.97 eBay |
| 174-6854 | Hydrosolv 100 liquid cleaner, 19 L (5 US gallon) | Service part / kit | Amazon eBay NAPA $10.64 | |
| 2323232 | Connecting rod | Service part / kit | eBay $201.50 | |
| 2613291 | MOTOR GP-ELECSTG | 1 | Service part / kit | eBay |
| 3395996 | CHARGER-BATTERY | 1 | Service part / kit | eBay |
| 4864557 | HEATER GP-GEN | 1 | Service part / kit | eBay |
| 5770040 | HEATER GP-JW BSC | 1 | Service part / kit | eBay |
| 7L7871 | 24 VOLT BATTERY SET / BATTERY GP | 1 | Service part / kit | eBay |
| 7L7872 | 24 VOLT BATTERY SET | 1 | Service part / kit | eBay |
| BAT2429 | ENCLO BATT 24V WET 1400CCA 29 | 1 | Service part / kit | eBay |
| BTC1038 | ENCLOSURE BATT CHARGER 10A | 1 | Service part / kit | eBay |
| ELSM248 | ELEC. START MOTOR HEAVY DUTY | 1 | Service part / kit | eBay |
| LF3239 | SERIES WIRED SPACE HEATERS | 1 | Service part / kit | eBay |
| LS1230 | ENCLOSURE HVY DUTY BATTERY SET | 1 | Service part / kit | eBay |
| R-20R2284 | C15/C18/C27/C32 ACERT Trim file (12-digit serial) | 1 | Service part / kit | Amazon eBay |
| R-20R2285 | C15/C18/C27/C32 ACERT Trim file (12-digit serial) | 1 | Service part / kit | Amazon eBay |
| SHK0022 | SPACE HEATER 1400S FRAME | 1 | Service part / kit | eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 100% | 4.54 | 1.2 |
Available documents
This page was generated from the 16 manufacturer documents above by automated extraction; every figure shown is copied from one of them. How the data is compiled.