HomeControllersEMCP 4.4

EMCP 4.4 Controller

The EMCP 4.4 is a generator-set controller. It is used on generator sets from Caterpillar and Depco, including the 3508, 3512, 3516 and EMCP 4.

25
Generator sets
2
Brands
300–1280 kW
Power range
2
Fuel types

Generator sets using this controller

25

Used across brands: Caterpillar, Depco

Caterpillar 3508Caterpillar 3512Caterpillar 3516Caterpillar EMCP 4Caterpillar EMCP 4.4Caterpillar XG135Caterpillar XQ 500Caterpillar XQ1140Caterpillar XQ570Caterpillar XQ800Caterpillar XQP1100Depco CG18 PGAM

Troubleshooting

6

Symptoms & remedies

SymptomRemedy
Engine exhaust in an enclosed areaStart the engine and operate it in a well ventilated area. Vent the engine exhaust to the outside if started in an enclosed area.
Engine overheating or accelerated wearStop the engine according to the procedure described in the Operation and Maintenance Manual, 'Engine Stopping' topic (Operation Section). Do not use the Emergency Stop Button for normal stopping. Correct any problem that caused an emergency stop before restarting.
Engine shutdown due to certain conditionsThe engine may shut down if it experiences: Engine overspeed, high aftercooler coolant temperature, high jacket water temperature, high crankcase pressure, or low engine oil pressure. Except for an overspeed shutdown, the monitoring system can be overridden.
Improper grounding of the engine electrical systemProper grounding is necessary for optimum performance and reliability. Use an engine-to-frame ground strap with a direct path to the battery. Ensure all grounds are tight and free of corrosion.
Loose or frayed electrical wiresCheck daily and tighten loose wires, repair frayed wires before starting the engine. See specific starting instructions in the Operation and Maintenance Manual.
Warning tag attached to the engine start switch or controlsDo NOT start the engine or move the controls. Consult with the person that attached the warning tag before starting.

Fault codes and symptom→remedy steps extracted from this controller’s service/owner documentation; verify against the official manual before servicing. Aggregated from the service documentation of generator sets built on this controller.