Specifications
| Fuel | diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 30 kW |
| Standby kVA | 37 |
| Prime power | 26 kW |
| Emissions | Tier II |
| Oil capacity | 10.0 L |
| Alternator | PX-332K2 |
| Voltage options | 12 V, 24 V |
| Phase | 1 & 3 |
| Rated current | [125, 250] A |
| Power factor | 1.0 |
| Battery cranking | 640 CCA |
| Battery voltage | 12 V |
| Dimensions (L×W×H) | 1422×737×779 mm |
| Dry weight | 657 kg |
Maintenance & consumables
for the Northern Lights 944 engine block| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Fuel filter | Full flow, spin-on fuel filter | — | find | ||
| Belt | Gear driven seawater pump, DC control plug is durable and reliable | — | find | ||
| Coolant | Standard heat exchanger cooling with optional keel cooling. Copper-nickel, tube-type heat exchanger has removable end caps for easy cleaning. Electrolysis protection via zinc anode. | — | |||
| Oil | — | 250 hr |
Common questions
What is the power rating of the Northern Lights M944?
The Northern Lights M944 is rated 30 kW standby (37.5 kVA).
What engine does the Northern Lights M944 use?
The Northern Lights M944 is powered by the Northern Lights 944 engine block engine.
What fuel does the Northern Lights M944 use?
The Northern Lights M944 runs on diesel.
What alternator does the Northern Lights M944 use?
The Northern Lights M944 uses a PX-332K2 alternator.
Troubleshooting
3Symptoms & remedies
| Symptom | Remedy |
|---|---|
| Temperature gauge above 205° F (96° C) | Shut off the engine immediately. Use the Trouble Shooting Guide on page 25 to isolate the cause of the overheat. Allow the engine to cool and then remove the cap slowly using protective clothing. Make repairs and restart after the temperature gauge registers below 200° F (94° C). Watch the temperature gauge regularly and turn off the unit if the temperature rises above 205° F (96° C). Repeat troubleshooting. |
| Engine oil consumption greater during break-in | Oil consumption is greater during break-in as piston rings take time to seat. Break-In Oil Changes: Change engine oil and filter at 50 hours. Change oil and filter again at 100 hours (consult Lubricants section for oil recommendation). |
| Engine does not start after 3 consecutive 20-second cranks | Remove the impeller from the seawater pump. This will prevent the muffler from fi lling with water and backfi lling the exhaust line and engine. Once the engine starts, shut if off immediately and reinstall the impeller. Restart and check the exhaust overboard outlet for gushes of water. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Parts
43| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 05-01260 | Sound Enclosure | Sound enclosure | PartsGeek | |
| 05-71250 | Sound Enclosure | Sound enclosure | PartsGeek | |
| 06-73100 | Sound Enclosure | Sound enclosure | PartsGeek | |
| 06-78000 | Sound Enclosure | Sound enclosure | PartsGeek | |
| 06-78100 | Sound Enclosure | Sound enclosure | PartsGeek | |
| 06-78600 | Sound Enclosure | Sound enclosure | PartsGeek | |
| 06-78700 | Sound Enclosure | Sound enclosure | PartsGeek | |
| 15.7 | DRIP PAN DRAIN 1/4" NPT | .6 | Drain | PartsGeek |
| 20.3 | CRANK CASE OIL FILTER | .8 | Oil filter | PartsGeek |
| 22-45600 | Circuit Breaker 100 ft. | Circuit breaker | PartsGeek | |
| 22-45601 | Y Harness | Y harness | PartsGeek | |
| 22-45610 | Circuit Breaker 10 ft. | Circuit breaker | PartsGeek | |
| 22-45620 | Circuit Breaker 20 ft. | Circuit breaker | PartsGeek | |
| 22-45630 | Circuit Breaker 30 ft. | Circuit breaker | PartsGeek | |
| 22-45640 | Circuit Breaker 40 ft. | Circuit breaker | PartsGeek | |
| 22-45650 | Circuit Breaker 50 ft. | Circuit breaker | PartsGeek | |
| 22-45670 | Circuit Breaker 70 ft. | Circuit breaker | PartsGeek | |
| 22-62125 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-65425 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70235 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70240 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70250 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70260 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70280 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70300 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70350 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-70375 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-93101 | Tough Series Controller 1ph Single Volt Off Unit M773LW3 | Controller | PartsGeek | |
| 22-93102 | Tough Series Controller 1ph Single Volt Off Unit M843NW3 | Controller | PartsGeek | |
| 22-95600 | S-1 Panel 12v/24v | Control panel | PartsGeek | |
| 22-95601 | S-3B Panel 12v/24v | Control panel | PartsGeek | |
| 22-95605 | S-1B Panel 12v/24v | Control panel | PartsGeek | |
| 22-95610 | Tough Series Controller 1ph Single Volt Off Unit M864W3/M944T/M944W3F/M944T3F | Controller | PartsGeek | |
| 22-95611 | S-3C Panel 12v | Control panel | PartsGeek | |
| 22-95612 | S-3C Panel 14v | Control panel | PartsGeek | |
| 22-98021 | Tough Series Controller 1ph Single Volt Off Unit M673LD3 | Controller | PartsGeek | |
| 22-98412 | Tough Series Controller 1ph Single Volt Off Unit M844DW3/M844LW3 | Controller | PartsGeek | |
| 306.3 | INTAKE AIR FILTER HOUSING | 12.1 | Air filter | PartsGeek |
| 41.2 | INTAKE AIR SNORKEL INLET | 1.6 | Intake air snorkel inlet | PartsGeek |
| 783.7 | CRANK CASE OIL FILL | 30.9 | Crank case oil fill | PartsGeek |
| 05-78010 | Sound Enclosure Assembly Instructions | Service part / kit | PartsGeek | |
| 92.5 | APPROX | 6.1 | Service part / kit | PartsGeek |
| OM944F | Safety Rules (Continued) | 1 | Service part / kit | PartsGeek |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | |||
| Prime | 50% | 5.03 | |
| Prime | 100% | 8.82 | |
| Standby | |||
| Standby | 50% | 6.05 | |
| Standby | 100% | 12.34 |