Home›Repair guides›Northern Lights›Adjust valve clearance

Northern Lights — Adjust valve clearance

Adjustments · valves

From a Northern Lights operator's manual covering: M30, M38C3, M38C3F, M40C3F, M944. Check it applies to your exact model before use.

Applies to: Northern Lights M30, Northern Lights M38C3, Northern Lights M38C3F, Northern Lights M40C3F, Northern Lights M944

Procedure

  1. Readjust after first 50 hours; check every 500 hours thereafter.
  2. Check valves when engine is cold.
  3. Rotate crankshaft clockwise to bring No. 1 piston to TDC compression.
  4. Align pulley notch with pointer; confirm No. 1 valves rock.
  5. Measure clearance with feeler gauge in firing order 1-3-4-2.
  6. Loosen lock nut, adjust screw until feeler gauge has slight drag.
  7. Tighten lock nut, recheck clearance, and replace rocker cover.

Tools required

Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.

Specs & values

  • Intake and exhaust cold clearance: 0.0098 in. (0.25 mm)
  • Firing order 1-3-4-2

Full service-parts list: Northern Lights M30 →, Northern Lights M38C3 →, Northern Lights M38C3F →, Northern Lights M40C3F →, Northern Lights M944 →

Source: Northern Lights operator's manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.