Service parts for the 11EKOZD
Grouped by system, with how many of each the parts manual calls for.
Fuel system
1 requiredOil system
1 requiredBelts
1 requiredPrices captured from merchant listings; some links are affiliate links. Confirm against your serial number before ordering.
Specifications
| Fuel | diesel |
|---|---|
| Frequency | 60.0 Hz |
| Standby power | 11 kW |
| Standby kVA | 11 |
| Prime power | 11 kW |
| Emissions | Tier III |
| Controller | ADC IId |
| Oil capacity | 3.4 L |
| Alternator | Fast-Response X |
| Voltage options | 120 V, 120/240 V |
| Phase | 1 |
| Rated current | 91.7 A |
| Battery cranking | 650 CCA |
| Battery voltage | 12 V |
| Coolant capacity | 4.3 L |
| Dimensions (L×W×H) | 960×528×559 mm |
| Dry weight | 279 kg |
| Wet weight | 406 kg |
Maintenance & consumables
| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Fuel filter | Fuel Filter Element | ED0021752880-S | Amazon $13.88 eBay $49.95 KuduParts $14.00 | ||
| Oil filter | Oil Filter | ED0021752850-S | Amazon $23.95 eBay $24.95 | ||
| Belt | V-Belt (Seawater Pump) | 229125 | Amazon $53.99 eBay $22.07 FridayParts $62.70 |
Service intervals
32| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Crankcase oil | Change | 250 hr | 3 mo | First service — Replace the oil in the crankcase. Break-in period service indicated. |
| Fuel/water separator | Clean | 250 hr | 3 mo | Fuel/water separator cleaning. |
| Fuel/water separator | Drain | 250 hr | 3 mo | Fuel/water separator draining. Consult local distributor/dealer for service. |
| Lube oil filter element | Replace | 250 hr | 3 mo | First service — Replace the lube oil filter element. Break-in period service indicated. |
| Seawater pump belt tension | Adjust | 250 hr | 3 mo | First service — Check/adjust the seawater pump belt tension. Break-in period service indicated. |
| Battery cables | Clean | 500 hr | 6 mo | Clean the battery cables. |
| Coolant hoses | Inspect | 500 hr | 6 mo | Check the coolant hoses. |
| Electrical connections | Check | 500 hr | 6 mo | Check and tighten the electrical connections. |
| Fuel filter | Replace | 500 hr | 6 mo | Replace the fuel filter element. |
| Generator | Clean | 500 hr | 6 mo | Blow dust out of the generator. |
| Heat exchanger anticorrosion zinc anode (if equipped) | Check | 500 hr | 6 mo | Check the zinc anode. |
| Mounting bolts/vibromounts | Check | 500 hr | 6 mo | Check the mounting bolts/vibromounts and tighten if necessary. |
| Seawater pump impeller | Inspect | 500 hr | 6 mo | Check the seawater pump impeller. |
| Siphon break (if equipped) | Check | 500 hr | 6 mo | Check the function of the siphon break, if equipped. |
| Breather pipe | Check | 1000 hr | 12 mo | Check the breather pipe for obstructions. |
| Coolant | Replace | 1000 hr | 12 mo | Replace the coolant. |
| Coolant hoses | Replace | 1000 hr | 12 mo | Replace the coolant hoses. |
| Exhaust/water mixing elbow | Clean | 1000 hr | 12 mo | Clean the exhaust/water mixing elbow. |
| Fuel injection nozzle pressure | Test | 1000 hr | 12 mo | Inspect the fuel injection nozzle pressure (Engine S/M). |
| Fuel injectors | Test | 1000 hr | 12 mo | Inspect, clean, and test the fuel injectors (Engine S/M). |
| Fuel tank sediment / fuel tank | Drain | 1000 hr | 12 mo | Remove the sediment from the fuel tank and drain the fuel tank. |
| Heat exchanger anticorrosion zinc anode (if equipped) | Replace | 1000 hr | 12 mo | Replace the zinc anode. |
| Heat exchanger tube | Clean | 1000 hr | 12 mo | Clean the heat exchanger tube (Generator S/M). |
| Intake/exhaust valve clearance | Adjust | 1000 hr | 12 mo | Adjust the intake/exhaust valve clearance (Engine S/M). |
| Seawater pump impeller | Replace | 1000 hr | 12 mo | Replace the seawater pump impeller. |
| Slip rings and brushes (6EKOD/5EFKOD models) | Clean | 1000 hr | 12 mo | 6EKOD/5EFKOD Models: Clean the slip rings and inspect the brushes (Generator S/M). |
| Crankcase breather system | Inspect | 1500 hr | Inspect the crankcase breather system (Engine S/M). | |
| Timing belt | Replace | 4000 hr | Replace the timing belt (Engine S/M). | |
| Starter motor | Check | 5000 hr | Check the starter motor. | |
| Engine | Other | 10000 hr | Total engine overhaul (Engine S/M). | |
| Complete exhaust system | Inspect | 12 mo | Inspect the complete exhaust system. | |
| Remote start panel (if equipped) | Check | First service — Check the remote start panel operation. Break-in period service indicated. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
19| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Gap | Anticorrosion zinc anode dimensions | 10 (0.39) x 17 (0.67) | mm (in.) | diameter x length |
| Gap | Seawater pump belt deflection | 10 | mm (0.4 in.) | pressing with approx. 10 kg (22 lbs.) force at midpoint of longest span; recheck new belt after 10 minutes of operation |
| Other | Anticorrosion zinc anode replacement threshold | <50 | % of length/diameter | replace when percent of zinc remaining is below 50% |
| Pressure | Crank oil pressure (locked rotor) | 69 | kPa | locked rotor condition |
| Pressure | Low oil pressure shutdown trip point | 117 | kPa | at or below |
| Pressure | Low oil pressure warning trip point | 138 | kPa | at or below |
| Speed | Engine over speed shutdown trip point | 115 | % of rated speed | engine speed exceeds |
| Speed | Engine under speed shutdown trip point | 85 | % of rated speed | engine speed falls below |
| Speed | Overfrequency default setting | 110 | % of nominal | setting range 102%-140% of nominal; time delay 10 sec |
| Speed | Underfrequency default setting | 90 | % of nominal | inhibit time 10 sec; delay time 5 sec |
| Temperature | Coolant freeze protection (50% ethylene glycol) | -37 | °C (-34 °F) | 50% ethylene glycol solution |
| Temperature | Coolant overheating protection (50% ethylene glycol) | 129 | °C (265 °F) | 50% ethylene glycol solution |
| Temperature | High coolant temperature shutdown trip point | 110 | °C (230 °F) | trip point |
| Temperature | High coolant temperature warning trip point | 105 | °C (221 °F) | trip point |
| Voltage | High battery voltage default setting (12 V system) | 15 | V | range 13.2-16.2 |
| Voltage | Low battery voltage default setting (12 V system) | 12 | V | range 9.6-12.6 |
| Voltage | Overvoltage default setting | 120 | % of nominal | inhibit time 10 sec; delay time 2 sec |
| Voltage | Undervoltage default setting | 80 | % of nominal at 10 sec | inhibit time 10 sec; delay time 10 sec |
| Voltage | Voltage adjust range | ±10 | % of system voltage | upper limit +10%, lower limit -10% |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Recommended fluids
| Fluid | Grade | Standard | Ambient | Capacity | Notes |
|---|---|---|---|---|---|
| Coolant | 50% ethylene glycol and 50% clean, softened water | above -37°C | Provides freezing protection to -37 °C (-34 °F) and overheating protection to 129 °C (265 °F). Coolant capacities (including 0.24 L (8 oz.) recovery tank): 6EKOD/5EFKOD 3.0 L (3.2 Qts.); 9EKOZD/7EFKOZD 3.0 L (3.2 Qts.); 11EKOZD/9EFKOZD (1 Phase) 4.3 L (4.5 Qts.); 11EKOZD/9EFKOZD (3 Phase) 4.3 L (4.5 Qts.). Do not use alcohol or methanol antifreeze. | ||
| Engine oil | API classification CD or CF | See SAE viscosity selection chart (SAE 20W, 30, 40 mineral base; SAE 10W-30, 10W-40, 10W-60, 15W-40, 20W-60 semi-synthetic base; SAE 5W-30, 0W-30, 10W, 5W-40 synthetic base) | Oil capacities: 6EKOD and 5EFKOD 2.5 L (2.6 Qts.); 9EKOZD and 7EFKOZD 2.5 L (2.6 Qts.); 11EKOZD and 9EFKOZD (1 Phase) 3.4 L (3.6 Qts.); 11EKOZD and 9EFKOZD (3 Phase) 3.4 L (3.6 Qts.). Maintain level between Min and Max marks on dipstick. | ||
| Fuel | Diesel fuel oil | Cetane number minimum 51; viscosity 2.0/4.5 centistokes at 40 °C; density 0.835/0.855 kg/litre; distillation 85% at 350; sulphur maximum 0.05% of weight | Fuel with low sulphur content: API CF4, CG4. Fuel with high sulphur content: API CF, CD, CE. Never store diesel fuel in galvanized containers. Avoid storing fuel for more than one month. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
30| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| AC Sens Loss Low Shutdwn | AC Sensing Loss (Shutdown) | Loss of AC voltage shutdown occurs when the controller does not detect the nominal generator AC output voltage for more than 3 seconds after crank disconnect. | Shutdown | Contact an authorized distributor/dealer for service. |
| AC Sens Loss Warning | AC Sensing Loss Warning | Loss of AC voltage warning occurs when the controller does not detect the nominal generator set AC output voltage after crank disconnect. | Warning | Contact an authorized distributor/dealer for service. |
| Aux Input Shutdwn | Auxiliary Input Shutdown | Auxiliary fault input shutdown; input from a customer-supplied switch that closes when the fault is active. | Shutdown | Check the cause of the auxiliary fault. |
| Backup Pars Status | Backup Parameters Loaded | Backup parameter firmware is now loaded on the controller. | Info | |
| Battery High Warning | High Battery Voltage Warning | High battery voltage warning; the fault condition clears when the battery voltage returns within limits (above 125% of nominal 12 V). | Warning | Check the battery rating and condition. |
| Battery Low Warning | Low Battery Voltage Warning | Low battery voltage warning; the fault condition clears when the battery voltage returns within limits (at or below 100% of nominal 12 V). | Warning | Check the battery rating and condition. Charge or replace the battery. |
| Coolnt Temp High Shutdwn | High Coolant Temperature Shutdown | Occurs if the engine coolant temperature exceeds the default setting (at or above 110 °C / 230 °F). | Shutdown | Check for a low engine coolant level. Check seawater pump impeller, strainers, and seacock. |
| Coolnt Temp High Warning | High Coolant Temperature Warning | High coolant temperature warning (at or above 105 °C / 221 °F). | Warning | Check for a low engine coolant level. Check seawater system for reduced flow. Allow the generator set to cool down before checking. |
| Eng Speed High Shutdwn | Engine Over Speed Shutdown | Occurs if the engine speed exceeds the default setting (above 115% of rated speed). | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| Eng Speed Low Shutdwn | Engine Under Speed Shutdown | Occurs if the engine speed falls below the default setting (below 85% of rated speed). | Shutdown | Contact an authorized distributor/dealer for service. |
| Engine Start Status | Engine Started | Generator set start circuit is closed allowing the engine to crank and run. | Info | |
| Engine Stop Status | Engine Stopped | Generator set start circuit is open causing the engine to shut down. | Info | |
| Exh Temp High Shutdwn | High Exhaust Temperature Shutdown | Occurs if the engine exhaust temperature exceeds the default setting. | Shutdown | Check the wiring to the sensor. Check for a clogged seawater intake or sea strainer. Check for a damaged seawater pump impeller. Check the exhaust system. |
| Frequency High Shutdwn | Overfrequency Shutdown | Occurs when the governed frequency exceeds the default setting of the system's frequency setpoint (above 110% of nominal). | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| Frequency Low Shutdwn | Underfrequency Shutdown | Occurs when the governed frequency falls below the default setting of the system's frequency setpoint (below 90% of nominal). | Shutdown | Reduce the load and restart the generator set. Contact an authorized distributor/dealer if problem continues. |
| Gen Running Notice | Generator Running | Generator set has started and is running. | Info | |
| Lo Crank Vlt Warning | Low Cranking Voltage Warning | Low cranking voltage warning (battery voltage drops below 60% of nominal 12 V). | Warning | Check the battery rating and condition. Charge or replace the battery. |
| Locked Rotor Shutdwn | Locked Rotor (Overcrank) Shutdown | Overcrank (locked rotor) shutdown; engine speed below 10 rpm and oil pressure below crank oil pressure (69 kPa). | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| Oil Pres Low Shutdwn | Low Oil Pressure Shutdown | Occurs if a low oil pressure condition exists (at or below 117 kPa). Note: does not protect against low oil level. | Shutdown | Check for leaks in the lubrication system. Check the oil level and add oil if the level is low. |
| Oil Pres Low Warning | Low Oil Pressure Warning | Low engine oil pressure warning (at or below 138 kPa). | Warning | Check for leaks in the lubrication system. Check the oil level and add oil if the level is low. |
| Over Crank Shutdwn | Overcrank Shutdown | Occurs after 3 unsuccessful starting attempts. | Shutdown | Check the fuel supply and battery. Also check for loose connections. Contact an authorized distributor/dealer if problem continues. |
| Preheat | Engine Start Aid Active | Start aid is active and will energize an engine equipped preheat or ether system during the crank cycle. | Info | |
| Remote Start Status | Remote Start | Generator set start circuit was closed from a remote location allowing the engine to crank and run. | Info | |
| RunRelCoil Shutdwn | Run Relay Coil Shutdown | Overload or perceived overload on the DC circuits provided through the controller (70 Run, 71 Crank, FP/FN Flash). | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| Sea Pressure Low Shutdwn | Low Seawater Pressure Shutdown | Occurs after a loss of seawater pressure is detected (5 seconds after detection). | Shutdown | Check for a clogged seawater intake or sea strainer. Check for a damaged seawater pump impeller. |
| Start Delay Notice | Engine Start Delay Active | The delay for engine start is active; the unit will start cranking after the time delay times out. | Info | |
| System Ready Status | System Ready | Generator set is in the AUTO mode and available to start if the start circuit is closed. | Info | |
| Timer Error Notice | System Timer Failed | Controller timer logic has failed to time out a designated function. | Info | |
| Volts xx-xx High Shutdwn | Overvoltage Shutdown | Occurs if the voltage exceeds the default setting of the voltage regulator setpoint (exceeds 120% of the AC system voltage). | Shutdown | Contact an authorized distributor/dealer for service if problem continues. |
| Volts xx-xx Low Shutdwn | Undervoltage Shutdown | Occurs if the voltage falls below the default setting of the voltage regulator setpoint (below 80% of the AC system voltage). | Shutdown | Reduce the load and restart the generator set. Check the F1 fuse. Contact an authorized distributor/dealer if problem continues. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
12Seawater Pump Belt Tensioning Procedure adjustment
⚠ Hazardous voltage. Moving parts. Operate the generator set only when all guards and electrical enclosures are in place.
- Remove the belt guard.
- Check the belt tension at the midpoint of the longest span by pressing with approx. 10 kg (22 lbs.) of force.
- Recheck a new belt tension after 10 minutes of operation.
- Loosen the pivot and adjusting screws.
- While prying the seawater pump outward, tighten the adjusting screw.
- Tighten the pivot screw.
- Recheck and adjust as necessary.
- Replace the belt guard.
Anticorrosion Zinc Anode Replacement maintenance
Tools: Wire brush
- With the generator set cooled, close the seacock, open the petcock on the engine, and drain the coolant.
- Remove the anticorrosion zinc anode (plug) from the heat exchanger.
- Use a wire brush to remove loose corrosion; replace the anode when <50% of length/diameter remains.
- Clean the threaded hole and coat the anode threads with pipe sealant suitable for marine applications.
- Cut the anticorrosion zinc to the correct length and install it into the heat exchanger.
- Close the petcock, open the seacock, and refill the cooling system.
- Start the generator set and check for leaks at the anticorrosion zinc anode location.
Flushing and Cleaning Procedure maintenance
⚠ Hot coolant and steam. Before removing the pressure cap, stop the generator set and allow it to cool.
- Open the pressure cap and open petcocks at the heat exchanger, engine block, and cooling system; let the system drain completely.
- Drain, clean, and flush the coolant recovery tank.
- Flush the system with clean water.
- Fill the system with recommended coolant.
Fuel Filter Cleaning/Replacement Procedure maintenance
⚠ Wash hands after any contact with fuel oil. Dispose of the fuel filter in an approved manner.
Tools: Rags
- Close the fuel supply valve.
- Loosen the fuel filter by turning it counterclockwise; remove and clean up spilled fuel oil.
- Clean the contact surface of the fuel oil filter adapter.
- Lightly lubricate the gasket surface of the new fuel filter with fresh fuel oil; thread on until gasket contacts, hand-tighten one-half turn.
- Open the fuel supply valve.
- Bleed the system.
Fuel System Bleed Procedure maintenance
⚠ Wipe up any spilled diesel fuel. Wash hands after any contact with fuel.
Tools: Rag
- Loosen the fuel filter's air vent screw.
- Initiate the auto/start sequence until fuel, free of air bubbles, flows from the vent screw.
- Tighten the fuel filter's air vent screw.
Fuel System Bleed Procedure (Preferred) maintenance
⚠ To prevent damage to the starter motor, do not crank the engine to prime the fuel system.
- Push the Power button on the Advanced Digital Control IId to the ON position.
- When run time hours appear, rotate the pushbutton/rotary selector dial until PUSH TO PRIME appears.
- Push the pushbutton/rotary selector dial.
- Rotate the pushbutton/rotary selector dial to CONFIRM PRIME: Yes.
- Push the pushbutton/rotary selector dial to begin the 30-second fuel priming sequence.
- Push the control knob to stop the priming procedure before 30 seconds if necessary.
Generator Set Storage Procedure maintenance
⚠ Do not allow coolant mixture to flow into waterways. Use antifreeze capable of withstanding the lowest possible temperatures.
- Start and run the generator set until it reaches operating temperature or about 15 minutes.
- Stop the generator set.
- Change the oil and oil filter.
- Close the seacock and remove the hose at the seacock; place the hose in a container of about 3.7-7.5 L (1-2 U.S. gallons) of coolant/antifreeze.
- Disconnect the lead (#87) to the low seawater pressure (LWP) switch.
- With a container at the exhaust outlet, run the generator set until coolant discharges or the mixture is depleted.
- Reconnect the lead (#87) to the low seawater pressure (LWP) switch.
- Stop the generator set.
- Connect a hose to the seacock; leave the seacock closed.
- Check the heat exchanger coolant level and add coolant if necessary.
- Clean the exterior and spread a light film of oil or silicon spray over exposed surfaces.
- Disconnect and remove the battery; store in a warm, dry location and recharge monthly.
- Select a well-ventilated (not humid or dusty) location to store the generator.
- Cover the entire unit with a dust cover.
- Run the generator set once a month whenever possible.
Impeller Inspection and Replacement Procedure maintenance
- Close the seacock.
- Remove the seawater pump coverplate.
- Remove the impeller.
- Inspect the impeller for damaged, cracked, broken, missing or flattened vanes; vanes should be straight and flexible.
- Lubricate the impeller with soapy water before installation.
- Install the impeller, pushing and rotating in the same direction as engine rotation until seated.
- Inspect the coverplate and gasket for corrosion and/or damage; replace as necessary.
- Lubricate the gasket with silicon grease and attach the gasket and coverplate.
- Open the seacock.
- Start the generator set and check for leaks.
- Stop the generator set and repair leaks or replace damaged or worn components.
Oil Change Procedure maintenance
⚠ Dispose of all waste materials (engine oil, fuel, filter, etc.) in an environmentally safe manner.
Tools: Oil filter wrench, Oil collection container
- Whenever possible, drain the oil while it is still warm.
- Place master switch OFF; disconnect power to battery charger; disconnect battery negative (-) lead first.
- Remove oil drain hose from retaining clip, remove cap, lower into oil collection container.
- Open the oil drain valve on the engine and allow the engine oil to drain completely; close the valve.
- Remove the oil filter by rotating it counterclockwise with an oil filter wrench.
- Apply a light coat of clean oil to the rubber seal of the new oil filter.
- Install the new oil filter following the instructions provided with the filter.
- Fill with new oil of the weight, grade, and quantity specified in Section 3.3.
- Reconnect the battery, negative (-) lead last; reconnect power to the battery charger.
- Start the generator set and check for leaks around the oil filter.
- Stop the generator set and tighten the oil filter to stop any leaks.
Seawater Pump Priming maintenance
- Close the seacock.
- Remove the hose from the seawater-filter outlet.
- Fill the hose and seawater pump with clean water.
- Reconnect the hose to the water filter outlet.
- Open the seacock.
- Confirm seawater pump operation on startup as indicated by water discharge from the exhaust outlet.
Siphon Break Inspection maintenance
⚠ Ensure that the siphon break's cap is tight before operating the generator set.
Tools: Mild detergent
- Stop the generator set.
- Remove the retaining cap and remove the reed valve for inspection.
- Use a mild detergent to remove residue and oxidation from the reed valve.
- Clear blockage from the reed valve opening.
- Replace the siphon break if the reed valve is cracked or the material has hardened or deteriorated.
- Install the reed valve into the mounting base with the valve downward.
- Install and only finger tighten the retaining cap.
Sound Shield Roof and Door Removal maintenance
⚠ Accidental starting. Disconnect the battery cables before working on the generator set. Remove the negative (-) lead first.
- Open the service-side door.
- Release the two wing nuts (if equipped) located underneath the roof.
- Lift up the roof.
- Slide the roof towards the service side of the unit for removal.
- Open the front, rear, and non-service side doors as needed.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Common questions
What is the power rating of the Kohler 11EKOZD?
The Kohler 11EKOZD is rated 11 kW standby (11.0 kVA).
What fuel does the Kohler 11EKOZD use?
The Kohler 11EKOZD runs on diesel.
Which alternator is fitted to the Kohler 11EKOZD?
The Kohler 11EKOZD uses a Fast-Response X alternator.
What oil filter does the Kohler 11EKOZD use?
The Kohler 11EKOZD uses oil filter part number ED0021752850-S.
Which fuel filter part number does the Kohler 11EKOZD take?
The Kohler 11EKOZD uses fuel filter part number ED0021752880-S.
Parts
69| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 102086 | HYDRAULIC TOWER | Gasket | Amazon eBay | |
| 102089 | Snap ring tongue jack | Belt | Amazon eBay | |
| 229125 | V-Belt (Seawater Pump) | 2 | Belt | Amazon $53.99 eBay $22.07 FridayParts $62.70 |
| 229826 | Seawater Pump Impeller Kit | 4 | Impeller | Amazon $27.95 eBay $45.71 FridayParts $33.59 |
| 260085 | ZINC ANODE KIT | 4 | Zinc anode kit | Amazon eBay $16.99 |
| ED001780 | Belt | Amazon eBay | ||
| ED0017801 | Belt | Amazon eBay | ||
| ED0021752850-S | Oil Filter | 4 | Oil filter | Amazon $23.95 eBay $24.95 |
| ED0021752880-S | Fuel Filter Element | 4 | Fuel filter | Amazon $13.88 eBay $49.95 KuduParts $14.00 |
| ED002816 | Belt | Amazon eBay | ||
| ED0028162 | Belt | Amazon eBay | ||
| ED007051 | Belt | Amazon eBay | ||
| ED0070511 | Belt | Amazon eBay | ||
| ED009732 | Belt | Amazon eBay | ||
| ED0097320 | Belt | Amazon eBay | ||
| ED009865 | Belt | Amazon eBay | ||
| ED0098653 | Belt | Amazon eBay | ||
| ED009881 | Belt | Amazon eBay | ||
| ED0098816 | Belt | Amazon eBay | ||
| GM102086 | Gasket | Amazon eBay | ||
| GM102089 | Belt | Amazon eBay | ||
| GM39266 | Fuse: Controller, Fuel Pump, and Fuel Shutoff Solenoid (F2) 20 Amp | 1 | Fuel pump | Amazon eBay $14.88 |
| GM74543 | Gasket | Amazon eBay | ||
| GM75706 | Gasket | Amazon eBay | ||
| GM77080 | Gasket | Amazon eBay | ||
| GM77379 | Glow plug | Amazon eBay | ||
| GM77898 | Belt | Amazon eBay | ||
| GM98756 | IMPELLER REPAIR KIT | 4 | Spark plug | Amazon eBay |
| X-6348-6 | DECAL | 12 | Decals | Amazon eBay |
| 103000 | Service part / kit | Amazon eBay FridayParts $99.99 | ||
| 103001 | Service part / kit | Amazon eBay FridayParts $58.99 | ||
| 11EKOZD | Service part / kit | Amazon eBay $113.50 FridayParts $120.01 | ||
| 239298 | Fuse: Customer Connection (F3) 5 Amp | 1 | Service part / kit | Amazon eBay $7.74 |
| 358337 | Fuse: Auxiliary Winding (F1) 10 Amp | 1 | Service part / kit | Amazon $101.99 eBay $45.17 |
| ED001050 | Service part / kit | Amazon eBay | ||
| ED0010509 | Service part / kit | Amazon eBay | ||
| ED001051 | Service part / kit | Amazon eBay | ||
| ED0010511 | Service part / kit | Amazon eBay | ||
| ED001261 | Service part / kit | Amazon eBay | ||
| ED0012610 | Service part / kit | Amazon eBay | ||
| ED001526 | Service part / kit | Amazon eBay | ||
| ED0015262 | Service part / kit | Amazon eBay | ||
| ED001630 | Service part / kit | Amazon eBay | ||
| ED0016300 | Service part / kit | Amazon eBay | ||
| ED001640 | Service part / kit | Amazon eBay $14.17 | ||
| ED0016401 | Service part / kit | Amazon eBay | ||
| ED001770 | Service part / kit | Amazon eBay | ||
| ED0017701 | Service part / kit | Amazon eBay | ||
| ED002280 | Service part / kit | Amazon eBay | ||
| ED0022801 | Service part / kit | Amazon eBay | ||
| ED006502 | Service part / kit | Amazon eBay | ||
| ED0065025 | Service part / kit | Amazon eBay | ||
| ED008211 | Service part / kit | Amazon eBay | ||
| ED0082112 | Service part / kit | Amazon eBay | ||
| ED008430 | Service part / kit | Amazon eBay | ||
| ED0084300 | Service part / kit | Amazon eBay | ||
| ED008480 | Service part / kit | Amazon eBay | ||
| ED0084800 | Service part / kit | Amazon eBay | ||
| ED009080 | Service part / kit | Amazon eBay | ||
| ED0090801 | Service part / kit | Amazon eBay | ||
| ED0090802150-S | Zinc Anode | 4 | Service part / kit | Amazon eBay $60.67 |
| ED0090802840-S | Zinc Anode | 4 | Service part / kit | Amazon eBay $92.76 |
| GM103000 | Service part / kit | Amazon eBay | ||
| GM103001 | Service part / kit | Amazon eBay | ||
| GM73473 | Service part / kit | Amazon eBay | ||
| GM73474 | Service part / kit | Amazon eBay | ||
| GM75627 | Service part / kit | Amazon eBay | ||
| GM76137 | Service part / kit | Amazon eBay | ||
| GM77911 | Service part / kit | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| 25% | 1.5 | 0.4 | |
| 50% | 2.3 | 0.6 | |
| 75% | 3.4 | 0.9 | |
| 100% | 4.5 | 1.2 | |
| Prime | 25% | 1.5 | 0.4 |
| Prime | 50% | 2.3 | 0.6 |
| Prime | 75% | 3.4 | 0.9 |
| Prime | 100% | 4.5 | 1.2 |