Kohler — Controller Resetting (Following System Fault Shutdown)

Repair & overhaul · Advanced Digital Control IId

From a Kohler operator's manual covering: 11EKOD, 11EKOZD, 5EFKOD, 5EFKOZD, 6EKOD, 6EKOZD, 7- 9EFKOZD, 7EFKOZD, 9- 11EKOZD, 9EFKOD, 9EFKOZD, 9EKOZD. Check it applies to your exact model before use.

Applies to: Kohler 11EKOZD, Kohler 5EFKOD, Kohler 6EKOD, Kohler 7EFKOZD, Kohler 9EFKOZD, Kohler 9EKOZD

Before you start

  • Always identify and correct the cause of a fault shutdown before resetting the controller.

Procedure

  1. Disconnect the generator set from the load.
  2. Identify and correct the cause of the fault shutdown.
  3. Use the pushbutton/rotary selector dial to select the Overview page.
  4. Press the dial to view the active fault; press again and use the dial to CONFIRM CLR FAULT: YES.
  5. Push the pushbutton/rotary selector dial.
  6. Start the generator set by pressing the start/stop button to START; test operate.
  7. Shut the generator off by pressing the start/stop to the STOP position.
  8. Reconnect the generator set to the load.