Specifications
Ratings spec sheet not in our library yet — see the documents below.
Filters & service parts
model family| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | Clean intake filter | — |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number.
Service intervals
5| Item | Action | Hours | Months | Notes |
|---|---|---|---|---|
| Enclosure exterior | Clean | 12 mo | Clean with a soft cloth. | |
| Intake and exhaust vents | Inspect | 12 mo | Verify vents are clear at all times. | |
| Intake filter | Clean | 12 mo | Annual maintenance. | |
| Surrounding area | Inspect | 12 mo | Ensure area free of leaves, pet hair, or other debris that could obstruct airflow. | |
| Unit | Inspect | 12 mo | Look for blocked vents, dirty intake filter, loose/missing hardware, loose or broken electrical connections. |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Service specifications
13| Type | Item | Value | Unit | Condition |
|---|---|---|---|---|
| Speed | OF1 trip frequency (UL 1741-SB / IEEE 1547-2018) | 61.2 | Hz | clearing time 300 s |
| Speed | OF2 trip frequency (UL 1741-SB / IEEE 1547-2018) | 62 | Hz | clearing time 0.16 s |
| Speed | UF1 trip frequency (UL 1741-SB / IEEE 1547-2018) | 58.5 | Hz | clearing time 300 s |
| Speed | UF2 trip frequency (UL 1741-SB / IEEE 1547-2018) | 56.5 | Hz | clearing time 0.16 s |
| Torque | AC wiring terminals, 8 to 6 AWG | 13.3 in-lb to 15.9 in-lb (1.5 Nm to 1.8 Nm) | in-lb | Terminal temp range up to 248 degF (120 degC); wire min temp rating 194 degF (90 degC) |
| Torque | DC wiring terminals, 10 to 6 AWG | 12 in-lb (1.35 Nm) | in-lb | Terminal temp range -40 to 266 degF (-40 to 130 degC); wire min temp rating 194 degF (90 degC) |
| Torque | Grounding bar terminals, 10 AWG wire | 30 in-lb (4 Nm) | in-lb | |
| Torque | Grounding bar terminals, 4-6 AWG wire | 45 in-lb (5 Nm) | in-lb | |
| Torque | Grounding bar terminals, 8 AWG wire | 40 in-lb (4.5 Nm) | in-lb | |
| Voltage | OV1 trip voltage (UL 1741-SB / IEEE 1547-2018) | 110 | % of nominal | clearing time 13 s |
| Voltage | OV2 trip voltage (UL 1741-SB / IEEE 1547-2018) | 120 | % of nominal | clearing time 0.16 s |
| Voltage | UV1 trip voltage (UL 1741-SB / IEEE 1547-2018) | 88 | % of nominal | clearing time 21 s |
| Voltage | UV2 trip voltage (UL 1741-SB / IEEE 1547-2018) | 50 | % of nominal | clearing time 2 s |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Fault codes
35| Code | Name | Meaning | Severity | Action |
|---|---|---|---|---|
| 0X7700 | Configuration Error Code 0 | AC-Coupled PV is not supported on this inverter hardware version. Newer hardware is needed. | Replace Inverter with an XVT model Inverter (Hardware version 1010 or later) to configure the PWRcell system for AC-Coupled PV. | |
| 0X7701 | Configuration Error Code 1 | The PWRcell Inverter is not configured for islanding. This is required for AC-Coupled PV. | Use the Inverter Mod. Settings to set 'EnaIslanding' to 'on'. | |
| 0X7702 | Configuration Error Code 2 | The PWRcell Inverter is configured for an incorrect number of ATSes. For AC-Coupled PV, 1 ATS should be used. | Verify that only 1 ATS is installed. Use the Inverter 'Mod. Settings' to set 'NumTranSwtchs' to '1'. | |
| 0X7703 | Configuration Error Code 3 | AC Generator integration is not supported on this inverter hardware version. Newer hardware is needed. | Replace Inverter with an XVT model Inverter (Hardware version 1010 or later). | |
| 0X7704 | Configuration Error Code 4 | The PWRcell Inverter is not configured for islanding. This is required for AC Generator Integration. | Use the Inverter 'Mod. Settings' to set 'EnaIslanding' to 'on'. | |
| 0X7705 | Configuration Error Code 5 | The PWRcell Inverter is configured for an incorrect number of ATSes. For AC Generator Integration, 1 or 2 ATSes should be used. | Verify the number of ATSes installed. Use the Inverter Mod. Settings to set 'NumTranSwtchs' to '1' or '2'. | |
| 0X7706 | Configuration Error Code 6 | The PWRcell Inverter is configured for 2 ATSs, but 'ACGenPower' is set to '0'. | Use the Inverter 'Mod. Settings' to set 'ACGenPower' to the correct value based on the nameplate power rating of the integrated generator. | |
| 0X7707 | Configuration Error Code 7 | The PWRcell Inverter is configured for AC Generator Integration, but the installed PWRcell ATS(s) do not have the correct controller. | Use the PWRcell ATS Controller Upgrade Kit (Model G0080060). | |
| 0X7708 | Configuration Error Code 8 | 'ACGenPower' setting is not configured between 9 kW and 26 kW for AC generator integration. | Adjust the value of 'ACGenPower' in 'Mod. Settings' to match the AC generator nameplate power value. Must be at least 9 kW. | |
| 0X7709 | Configuration Error Code 9 | The PWRcell Inverter is configured for both AC-Coupled PV and AC Generator Integration. Only one of these features can be supported on a single system. | If supporting AC Coupled PV, set 'ACGenPower' to '0'. If supporting AC Generator Integration, set 'ACPVPower' to '0'. | |
| 0X770A | Configuration Error Code A | The PWRcell Inverter is configured for 3-phase applications. AC-Coupled PV and AC Generator Integration are only supported with 1-phase applications. | Install a single-phase inverter if the application is for a single phase service. Otherwise set 'ACPVPower' and 'ACGenPower' to '0'. | |
| 0X770B | Configuration Error Code B | The PWRcell Inverter is configured for 1 or more ATS but is not configured for islanding. | If 1 or more ATS is installed, set 'EnaIslanding' to 'on'. If no ATS is installed, set 'NumTranSwtchs' to '0'. | |
| 0X770C | Configuration Error Code C | The PWRcell Inverter is configured for 1 or more ATS but is also configured for 3-phase applications. | Install a single-phase PWRcell Inverter if the application is for a single-phase service. Otherwise ensure 'NumTranSwtchs' is set to '0'. | |
| 0X770D | Configuration Error Code D | Bad input phase angle. Phase angle has been detected to be 120 degrees or less. For single-phase services, this should be 180 degrees. | Check voltage measurement and make sure the system is wired up correctly to a 120/240 Vac single-phase (Wye) service. | |
| 0X7720 | Wiring Error Code 0 | The PWRcell Inverter is configured for AC Generator Integration but no ATS has been detected. | Check the ATS & CTs Cat 5 cables are intact and connected to the correct ports. Check the ATS limit switch is connected to the 'Auxiliary Contact' port. | |
| 0X7721 | Wiring Error Code 1 | The PWRcell Inverter is NOT configured for an ATS, but an ATS has been detected. | Verify the number of ATSes installed. Use the Inverter 'Mod. Settings' to set 'NumTranSwtchs' to '1' or '2'. | |
| 0X7722 | Wiring Error Code 2 | The Line 1 and Line 2 wires are swapped somewhere between the 'N' terminals of the PWRcell ATS and the Protected Loads terminals of the inverter. | Check that phase wiring does not cross over or change along each respective path from N1, N2 to L1, L2. | |
| 0X7724 | Wiring Error Code 4 | The Line 1 and Line 2 wires are swapped somewhere between the 'E' terminals of the PWRcell ATS and the Protected Loads terminals of the inverter. | Check that phase wiring does not cross over or change along each respective path from E1, E2 to L1, L2. | |
| 0X7726 | Wiring Error Code 6 | The inverter ATS did not transfer back to the utility/grid-connected position (UP position). | Verify wiring to the 'N' terminals of the inverter ATS is correct. Verify the Cat 5 cable for Inverter ATS Control is terminated properly. Verify factory wiring at the transfer mechanism closing coils and relays. | |
| 0X7727 | Wiring Error Code 7 | The inverter ATS did not transfer to the backup power source position (DOWN position). | Verify wiring to the 'E' terminals of the inverter ATS is correct. Verify the Cat 5 cable for Inverter ATS Control is terminated properly. Verify wiring to the inverter AC Grid Connection terminals. | |
| 0x8061 | ct cal = 1 | Line 1 doesn't have a valid CT calibration | ||
| 0x8062 | ct cal = 2 | Line 2 doesn't have a valid CT calibration | ||
| 0x8063 | ct cal = 3 | Line 1 & 2 don't have a valid CT calibration | ||
| 0x8064 | ct cal = 4 | Line 3 doesn't have a valid CT calibration | ||
| 0x8065 | ct cal = 5 | Line 1 & 3 don't have a valid CT calibration | ||
| 0x8066 | ct cal = 6 | Line 2 & 3 don't have a valid CT calibration | ||
| 0x8067 | ct cal = 7 | Line 1 & 2 & 3 don't have a valid CT calibration | ||
| 0x8069 | ct cal = 9 | Line 1 has multiple CTs on it (or a CT is on the neutral wire) | ||
| 0x806A | ct cal = A | Line 2 has multiple CTs on it (or a CT is on the neutral wire) | ||
| 0x806B | ct cal = B | Lines 1 and 2 have multiple or missing CTs on them (or a CT is on the neutral wire) | ||
| 0x806C | ct cal = C | Line 3 has multiple CTs on it (or a CT is on the neutral wire) | ||
| 0x806D | ct cal = D | Lines 1 & 3 have multiple or missing CTs on them (or a CT is on the neutral wire) | ||
| 0x806E | ct cal = E | Lines 2 & 3 have multiple or missing CTs on them (or a CT is on the neutral wire) | ||
| 0x806F | ct cal = F | Lines 1 & 2 & 3 have multiple or missing CTs on them (or a CT is on the neutral wire) | ||
| 0x8070 | ct cal success | Calibration was successful | Info |
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Procedures
7Configuring Static IP Settings installation
Tools: Smartphone or laptop
- From the REbus Beacon device page on the inverter screen, select the Installer Tool.
- After logging into the Installer Configuration Tool, select 'Beacon' from the menu.
- Select 'Simple IP Network Settings'.
- Adjust Name, Config, Address, Netmask, Gateway, DNS1, DNS2, MAC as needed.
- Press Submit to commit settings.
Mounting the Inverter installation
⚠ Equipment damage. Mount inverter to a strong, stable surface. Never mount to drywall, plaster, or other non-structural wall treatments.
Tools: 1/4 in fasteners, Anchors or blocking as needed
- Verify mounting location meets all PWRcell Inverter requirements in Section 3.
- Mount inverter upright on a vertical wall. Never obstruct or allow water into intake or exhaust vents.
- Secure mounting bracket to mounting surface through mounting holes.
- Insert mounting bracket tabs into inverter body slot.
- Secure bottom of inverter to wall with two fasteners through mounting holes spaced 11 1/4 in apart.
STOP Terminal Wiring (PV only, without PWRcell Battery) installation
Tools: 20-14 AWG two-conductor cable (600 V insulation)
- Verify the PWRcell system is powered down.
- Remove the jumper from the inverter STOP terminals.
- Use 20-14 AWG two-conductor cable with 600 V insulation to connect a switch that is lockable, UL listed, and rated at least 12 VDC, 5 mA.
Accessing Wiring Compartment maintenance
⚠ The inverter interior is not weather-proof. Do not open the inverter front cover when wet or during rain/snowfall.
Tools: Multi-meter
- Open inverter front cover by lifting the bottom to just beyond horizontal and pushing inward.
- Locate wiring compartment cover.
- Remove five M4X10 screws and wiring compartment cover.
- Verify all PWRcell DC and AC terminals are below 10 V using a multi-meter.
Cleaning Intake Filter maintenance
Tools: Soft brush, Vacuum cleaner
- Clean intake filter with a soft brush or vacuum cleaner.
- If air filter is damaged or difficult to clean, contact an IASD or Generac Customer Service for a replacement filter.
Perform an AC Generator Manual Override operation
⚠ Upon restoration of grid power, the manual override command will be cleared.
- From the home screen, use the right arrow key to navigate to the inverter device page.
- Push the center button to access the inverter device main menu.
- Use the down arrow key to navigate to the bottom of the inverter device menu.
- Navigate to the AC Generator Manual Override option: 'AutoACGenCtrl', 'TurnACGenOn', or 'TurnACGenOff'.
- Use the center button to select the AC Generator Manual Override option.
Replacing Fuses repair
⚠ Never replace a fuse with a different size or style. Doing so will void the inverter warranty.
⚠ Never remove DC fuses under load.
Tools: Multi-meter
- Initiate an inverter shutdown.
- Open all PWRcell DC Disconnects. Verify DC voltage reported on LCD screen has dropped below 10 VDC.
- Disconnect all sources of AC and DC power.
- Remove wiring compartment cover.
- Locate DC fuse holders.
- Using a multi-meter, verify all PWRcell DC and AC terminals are below 10 V.
- Press fuse holder up and turn counterclockwise to release.
- Remove fuse from fuse holder and check for continuity using a multi-meter.
- Insert replacement fuse into fuse holder.
- Reinstall fuse holder. Turn clockwise until tight.
Extracted from the manufacturer documentation linked to this model. Values are copied as printed; confirm against your unit's manual and serial number.
Parts
2model family| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 10000005117 | 240 VAC, 6.3 Amps, 10,000 AIC | 1 | Fuse | Amazon eBay $19.99 |
| A0002532225 | Contrôleur d’ATS PWRcell (réf. A0002532225) | Service part / kit | Amazon eBay $99.99 |
Compiled from this model's family documentation — may include parts for closely-related variants. Confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.