Generac S2502HC / XVT076A03 — STOP Terminal Wiring (PV only, without PWRcell Battery)
Installation · Inverter STOP terminals
For the Generac S2502HC / XVT076A03, from the Generac service manual.
Browse Generac generators & specs →
Procedure
- Verify the PWRcell system is powered down.
- Remove the jumper from the inverter STOP terminals.
- Use 20-14 AWG two-conductor cable with 600 V insulation to connect a switch that is lockable, UL listed, and rated at least 12 VDC, 5 mA.
Tools required
- 20-14 AWG two-conductor cable (600 V insulation) Amazon
Tool links are Amazon searches (affiliate links); manufacturer special tools may only be available from a dealer.
Specs & values
- Switch rated at least 12 VDC, 5 mA
- Cable 20-14 FridayParts $45.99 AWG, 600 V insulation
Source: Generac service manual. Steps and values are as documented; always cross-check against the official manual and any later revisions for your exact serial number before servicing.