HomeGeneracGenerac MMG100

Generac MMG100 Generator Set

The Generac MMG100 is a 75 kW (107 kVA) Diesel standby generator set powered by a John Deere PE4045HFG92 engine. It is available at 120 V and 277 V, L-N-phase, 60 Hz and rated 305 A. It holds about 15.5 L (4.1 gal) of oil and 22 L (5.8 gal) of coolant, with a maximum ambient rating of 49 °C. Starting uses 1 group-24 battery rated 720 CCA at 12 V. The set measures 3020×1020×1570 mm (118.9×40.2×61.8 in), weighs about 1714 kg (3779 lb) and produces 68 dBA at 7 m. An integrated tank holds 625 L (165.1 gal), roughly 24 hours of runtime. The same PE4045HFG92 engine also powers generator sets from John Deere, Magnum and OneSource Rental.

75 kW
Standby
4.5 L
Displacement
15.5 L
Oil capacity
5
Document types

How to read your Generac serial & model number →

Specifications

FuelDiesel
Frequency60.0 Hz
Standby power75 kW
Standby kVA107
Prime power71 kW
EmissionsInterim Tier 4
ControllerPower Zone
Oil capacity15.5 L
AlternatorMarathon 363CSL1608 (1650)
Voltage options120 V, 240 V, 208 V, 277 V, 480 V
PhaseL-N
Rated current305 A
Power factor[1, 0.8]
Circuit breaker[400, 450, 600] A
Battery group24
Battery cranking720 CCA
Battery voltage12 V
Battery quantity1
Max ambient49 °C
Dimensions (L×W×H)3020×1020×1570 mm
Dry weight1714 kg
Sound level68.0 dBA @ 7 m
Fuel tank625.0 L
Tank runtime24 hr

Engine

John Deere PE4045HFG92
Oil capacity14.7 L
Coolant capacity22.0 L
Displacement4.5 L
Aspirationturbocharged
Rated speed1800 rpm

Maintenance & consumables

for the John Deere PE4045HFG92
ItemSpecCapacityPart #Interval
Air filter3000 hr find
Fuel filter1000 hr find
Oil filter500 hr find
Belt18000 hr find
Coolant20.818000 hr
Coolant filter find
Oil15.51000 hr

Common questions

What is the power rating of the Generac MMG100?

The Generac MMG100 is rated 75 kW standby (107.0 kVA).

What engine does the Generac MMG100 use?

The Generac MMG100 is powered by the John Deere PE4045HFG92 engine.

What fuel does the Generac MMG100 use?

The Generac MMG100 runs on Diesel.

What is the oil capacity of the Generac MMG100?

The John Deere PE4045HFG92 engine in the Generac MMG100 has an oil capacity of 14.7 liters.

What alternator does the Generac MMG100 use?

The Generac MMG100 uses a Marathon 363CSL1608 (1650) alternator.

Troubleshooting

3

Symptoms & remedies

SymptomCauseRemedy
Low Fuel LevelShutdown, Low fuel level, Unit not level, Fuel tank leaking, Damaged fuel sender or wiringCheck fuel level in LCD window of controller. Confirm that unit is sitting level to ensure an accurate reading. Check tank for leaks. Check for continuity between sender and engine controller.
Low Oil PressureShutdown, Low oil level, Oil leaking from engine, Oil pressure senderCheck oil level on dipstick. Add oil, if needed. Visually inspect the engine for leaks. Restart unit and verify loss of pressure. Shut down immediately if pressure does not reach 5 psi (34 kPa) within five seconds. See engine operator’s manual to identify corrective action.
Low Coolant LevelShutdown, Low coolant level, Coolant hoses leaking, Engine block or water pump leakingAllow engine to cool, then check coolant level in radiator. Add coolant, if needed.

Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.

Parts

47
Part #DescriptionQtySystem
00087Twist-Lock Receptacles1Receptacle PartsGeek
002815Emergency Stop Switch1Emergency stop switch PartsGeek
002816Lug Sequence1Ecu override switch PartsGeek
00452120V GFCI Receptacles1Receptacle PartsGeek
0045320A Circuit Breakers1Breaker PartsGeek
100-025Air Filter1Air filter PartsGeek
100-030Oil Filter1Oil filter PartsGeek
100-045Fuel Filter1Oil filter PartsGeek FridayParts $20.19
100-060Coolant Filter1Coolant filter PartsGeek
100-085Belt2Belt PartsGeek
100-100Spark Plug1Spark plug PartsGeek
25-1476Air Filter Minders1Air filter PartsGeek
25-1483Primary Air Cleaners1Air filter PartsGeek
25-1639Fuel Filters1Fuel filter PartsGeek
25-1648Oil Filters1Oil filter PartsGeek
000100aConsult Manual. Read and understand manual completely before using product. Failure to completely understand manual and product could result in death or serious injury.1Service part / kit PartsGeek
000155AVERTISSEMENT Seul un électricien formé et agréé devrait s’occuper du câblage et des connexions à l’appareil. Le non-respect des exigences d’installation pourrait entraîner la mort ou des blessures graves et des dommages à l’équipement ou aux biens.Service part / kit PartsGeek
000156WARNING: Do not disable or modify the connection box door safety switch. Doing so will result in death or serious injury.Service part / kit PartsGeek
000157WARNING: Do not make any connections directly to the lugs without routing the cables through the opening. Use a hex-wrench to tighten the cable connections.Service part / kit PartsGeek
000190DANGERService part / kit PartsGeek
000226WARNING: Do not make any connections directly to the lugs without routing the cables through the opening. Use a hex-wrench to tighten the cable connections.Service part / kit PartsGeek
002803Voltage Adjust ScreenService part / kit PartsGeek
002804Prestart ScreenService part / kit PartsGeek
002805Status Generator at Rest Stop Mode 22:31Service part / kit PartsGeek
01525Fuel return1Service part / kit PartsGeek
01526Fuel pickup1Service part / kit PartsGeek
01528Roof assembly1Service part / kit PartsGeek
12142DECAL, GROUND1Service part / kit PartsGeek
18394Fitting, plug, .500NPT1Service part / kit PartsGeek
18396Decal, Panel Light Switch, Single1Service part / kit PartsGeek
20241BWeldment, RH door post - mid1Service part / kit PartsGeek
20242BWeldment, LH door post - mid1Service part / kit PartsGeek
20785BBrace, side - mid (A)2Service part / kit PartsGeek
22369BWeldment, skid1Service part / kit PartsGeek
23131BWeldment, skid adapter1Service part / kit PartsGeek
23597Decal, Panel Light Switch (Optional)1Service part / kit PartsGeek
23827Decal, Controller Switches1Service part / kit PartsGeek
23846Decal, Controller Instructions1Service part / kit PartsGeek
24904Decal, 4 pos. Outlet Usage in Delta1Service part / kit PartsGeek
26844BWeldment, lift channel - mid1Service part / kit PartsGeek
30175Decal, UN31A tank caution Located on tank.1Service part / kit PartsGeek FridayParts $85.00
33787Decal, Generator - Voltage Configuration (MMG100CAN6 Only)1Service part / kit PartsGeek
34274Decal, Generator - 600V Circuit Breakers (MMG100CAN6 Only)1Service part / kit PartsGeek
60145Nut, .375-16 sflg lock12Service part / kit PartsGeek
60202Screw, M12-1.75 x 35 sflg hx G10.916Service part / kit PartsGeek
60323Screw, .375-16 x 1.50 std hex, G84Service part / kit PartsGeek
60451Screw, .375-16 x .625 flg hex6Service part / kit PartsGeek

Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.

Fuel consumption

RatingLoadL/hgal/h
Prime
Prime100%23.5
Standby
Standby25%3.80.97

Available documents

Spec sheet — Turnkey-Industries-Magnum-MMG100D-Spec-Sheet (Generac)Operator's manual — Generac Towable Diesel Generator - MMG75D-MMG100D Owners Manual (Generac)Owner's manual — 33701 (Generac)Owner's manual — MMG75D-100D-Ops-03-15-13-32668-B (Generac)Parts manual — Generac Mobile Diesel Generator Brochure (Generac)Service manual — 26513 (Generac)Service manual — 26635 (Generac)