Specifications
| Frequency | 60.0 Hz |
|---|---|
| Standby power | 107 kW |
| Standby kVA | 133 |
| Prime power | 98 kW |
| Controller | Power Zone |
| Oil capacity | 15.5 L |
| Alternator | Marathon 362PSL1606 (1650) |
| Voltage options | 120 V, 139 V, 208 V, 220 V, 240 V, 277 V |
| Phase | 1Ø,3Ø |
| Rated current | [313, 325] A |
| Power factor | [1, 0.8] |
| Dry weight | 3780 kg |
| Fuel tank | 625.0 L |
| Tank runtime | 24 hr |
Engine
| Oil capacity | 14.7 L |
|---|---|
| Coolant capacity | 4.5 L |
| Displacement | 4.5 L |
| Aspiration | turbocharged |
| Rated speed | 1800 rpm |
Maintenance & consumables
for the John Deere PE4045HFG92| Item | Spec | Capacity | Part # | Interval | |
|---|---|---|---|---|---|
| Air filter | — | 300 hr | |||
| Fuel filter | — | 1000 hr | |||
| Oil filter | — | 300 hr | |||
| Battery | — | 250 hr | |||
| Belt | — | 500 hr | |||
| Coolant | 20.8 | — | 1000 hr | ||
| Coolant filter | — | ||||
| Oil | 15.5 | — | 300 hr | ||
| Spark plug | — | 1000 hr |
Common questions
What size generator is the Magnum MMG100D Super Start?
The Magnum MMG100D Super Start is rated 107 kW standby (133.0 kVA).
Which engine powers the Magnum MMG100D Super Start?
The Magnum MMG100D Super Start is powered by the John Deere PE4045HFG92 engine.
What is the oil capacity of the Magnum MMG100D Super Start?
The John Deere PE4045HFG92 engine in the Magnum MMG100D Super Start has an oil capacity of 14.7 liters.
What alternator does the Magnum MMG100D Super Start use?
The Magnum MMG100D Super Start uses a Marathon 362PSL1606 (1650) alternator.
Troubleshooting
3Symptoms & remedies
| Symptom | Cause | Remedy |
|---|---|---|
| LOW FUEL LEVEL SHUTDOWN | Fuel level is low, fuel tank has leaks, or fuel level sender and wiring are damaged. | Check the fuel level on the Home screen. Confirm that the generator is sitting level to ensure an accurate reading. Check for leaks in the fuel tank. If the fuel level is good and no leaks are found, check the fuel level sender and the connecting wiring for damage. |
| LOW OIL PRESSURE SHUTDOWN | Oil pressure is less than 20 psi (138 kPa), engine has oil leaks, or oil pressure sender is faulty. | Check the level of the engine oil with the dipstick. Visually inspect the engine for oil leaks. If the oil level is good, restart the unit and verify the loss of oil pressure. Check the oil pressure sender. |
| LOW COOLANT LEVEL SHUTDOWN | Coolant level in the radiator is low. | Allow the engine to cool. Check the coolant level in the radiator. |
Fault codes and symptom→remedy steps extracted from this model’s service/owner documentation; verify against the official manual before servicing.
Parts
11| Part # | Description | Qty | System | |
|---|---|---|---|---|
| 100-025 | Air Filter | 1 | Air filter | Amazon eBay |
| 100-030 | Oil Filter | 1 | Oil filter | Amazon eBay |
| 100-045 | Fuel Filter | 1 | Fuel filter | Amazon eBay FridayParts $20.19 |
| 100-060 | Coolant Filter | 1 | Coolant filter | Amazon eBay |
| 100-085 | Belt | 2 | Belt | Amazon eBay |
| 100-100 | Spark Plug | 1 | Spark plug | Amazon eBay |
| 25-1476 | Air Filter Minders | 1 | Air filter | Amazon eBay |
| 25-1483 | Primary Air Cleaners | 1 | Air filter | Amazon eBay |
| 25-1639 | Fuel Filters | 1 | Fuel filter | Amazon eBay |
| 25-1648 | Oil Filters | 1 | Oil filter | Amazon eBay |
| AN500T0106 | STARTER SWITCH | Starter | Amazon eBay |
Service, wear & replacement parts referenced for this model and its engine — confirm the exact part for your serial number. See the full parts catalog to search and cross-reference.
Fuel consumption
| Rating | Load | L/h | gal/h |
|---|---|---|---|
| Prime | 23.5 | 6.2 | |
| Standby | 18.1 | 4.78 |